Development and Validation of Liquid Chromatography-Tandem Mass Spectrometric Method for the Quantification of Diclofenac in Human Plasma

被引:0
|
作者
Grover, Parul [1 ]
Bhardwaj, Monika [2 ]
Mehta, L. [3 ]
Kumar, Sandeep [4 ]
机构
[1] Delhi NCR, KIET Grp Inst, KIET Sch Pharm, Ghaziabad 201206, Uttar Pradesh, India
[2] Indian Inst Integrat Med, Nat Prod Chem Div, Canal Rd, Jammu 180001, Jammu And Kashm, India
[3] Amity Univ, Amity Inst Pharm, Noida 201301, Uttar Pradesh, India
[4] Natl Inst Pharmaceut Educ & Res, Dept Regulatory Affairs, Hyderabad 500037, Telangana, India
关键词
Diclofenac; validation; liquid chromatography-tandem mass spectrophotometry; human; plasma; multiple reaction monitoring; pharmacokinetics; HPLC METHOD; PERFORMANCE; SODIUM;
D O I
暂无
中图分类号
R9 [药学];
学科分类号
1007 ;
摘要
According to Food and Drug Administration requirements, a simple, sensitive and specific liquid chromatography-tandem mass spectrophotometry method for quantifying diclofenac in human plasma was developed and fully validated. Electrospray ionisation in the positive mode produced protonated ions, which were utilised to detect analyte and fluconazole (internal standard). Protein precipitation generated by acetonitrile was used to extract the analytes, followed by liquid-liquid extraction with ethyl acetate. The reversed phase separation was performed on a Chromolith speed ROD RP-18e (4.6 mmx50 mm) column with a simple isocratic mobile phase of 10 mM ammonium acetate in water, pH adjusted to 4.5 using acetic acid:acetonitrile in the ratio of (20:80, v/v) at a flow rate of 0.5 ml min-1. On a triple quadrupole mass spectrometer, fragmentation of Diclofenac m/z 296.10- (parent) and 250 (product) and Fluconazole m/z 307.20- (parent) and 220 (product) for internal standard was monitored. The devised method was verified in human plasma spanning a concentration range of 18.75 to 2000.25 ng ml-1, with a correlation coefficient (r2) of 0.9948. The detection was carried out using an electrospray ionisation approach on a triple quadrupole mass spectrometer that was used for multiple reaction monitoring. The intraday precision and accuracy values obtained from six different sets of quality control samples evaluated on different occasions ranged from 96.22-113.46 % and 2.66-9.95 %, respectively. For the analyte and internal standard, the overall recoveries were 61.98 3.97 and 55.01 1.18, respectively. The described approach was used to analyse diclofenac in human plasma samples with great performance.
引用
收藏
页码:740 / 752
页数:13
相关论文
共 50 条
  • [41] QbD-Driven Development and Validation of Liquid Chromatography Tandem Mass Spectrometric Method for the Quantitation of Sildenafil in Human Plasma
    Hasnain, M. Saquib
    Ansari, Shaukat Ali
    Rao, Shireen
    Tabish, Mohammad
    Singh, Mukul
    Abdullah, Mohammad Syafiq
    Ansari, Mohammed Tahir
    JOURNAL OF CHROMATOGRAPHIC SCIENCE, 2017, 55 (06) : 587 - 594
  • [42] A Rapid and Sensitive Method for the Determination of Bisoprolol in Human Plasma by Ultra Performance Liquid Chromatography-Tandem Mass Spectrometry
    Jiang, Yihong
    Niu, Yaling
    Ning, Congchao
    Qin, Feng
    Yan, Chengda
    Lu, Xiumei
    BIOMEDICAL CHROMATOGRAPHY, 2025, 39 (05)
  • [43] Development and Validation of the New Liquid Chromatography-Tandem Mass Spectrometry Method for the Determination of Unbound Tacrolimus in the Plasma Ultrafiltrate of Transplant Recipients
    Bodnar-Broniarczyk, Magdalena
    Warzyszynska, Karola
    Czerwinska, Katarzyna
    Marszalek, Dorota
    Dziewa, Natalia
    Kosieradzki, Maciej
    Pawinski, Tomasz
    PHARMACEUTICS, 2022, 14 (03)
  • [44] Liquid chromatography-tandem mass/mass spectrometry method for the quantification of rabeprazole in human plasma and application to a pharmacokinetic study
    Yu, Liyan
    Deng, Haishan
    Xiang, Bingren
    ARZNEIMITTELFORSCHUNG-DRUG RESEARCH, 2010, 60 (05): : 262 - 266
  • [45] Development and validation of a liquid chromatography-tandem mass spectrometry assay for nine oral anticancer drugs in human plasma
    Janssen, Julie M.
    de Vries, Niels
    Venekamp, Nikkie
    Rosing, Hilde
    Huitema, Alwin D. R.
    Beijnen, Jos H.
    JOURNAL OF PHARMACEUTICAL AND BIOMEDICAL ANALYSIS, 2019, 174 : 561 - 566
  • [46] Quantification of L-ergothioneine in human plasma and erythrocytes by liquid chromatography-tandem mass spectrometry
    Wang, Ling-Zhi
    Thuya, Win-Lwin
    Toh, Dorothy Su-Lin
    Lie, Michael George-Limenta
    Lau, Jie-Ying Amelia
    Kong, Li-Ren
    Wan, Seow-Ching
    Chua, Kian-Ngiap
    Lee, Edmund Jon-Deoon
    Goh, Boon-Cher
    JOURNAL OF MASS SPECTROMETRY, 2013, 48 (03): : 406 - 412
  • [47] Liquid chromatography-tandem mass spectrometric method for the quantification of eliglustat in rat plasma and the application in a pre-clinical study
    Chen, Jingjing
    Shao, Yuanyuan
    Zhu, Huidan
    Chen, Xiufang
    Ye, Xuemei
    JOURNAL OF PHARMACEUTICAL AND BIOMEDICAL ANALYSIS, 2020, 177
  • [48] A liquid chromatography-tandem mass spectrometry method for the quantification of PAC-1 in rat plasma
    Fang, Li-Na
    Chen, Xiao-Hui
    Wang, Qiu-Di
    Zhang, Di
    Zhao, Juan-Juan
    Long, Zhi-Min
    Gong, Ping
    Bi, Kai-Shun
    JOURNAL OF PHARMACEUTICAL AND BIOMEDICAL ANALYSIS, 2011, 54 (01) : 225 - 229
  • [49] An ultra-high pressure liquid chromatography-tandem mass spectrometry method for the quantification of teicoplanin in plasma of neonates
    Begou, O.
    Kontou, A.
    Raikos, N.
    Sarafidis, K.
    Roilides, E.
    Papadoyannis, I. N.
    Gika, H. G.
    JOURNAL OF CHROMATOGRAPHY B-ANALYTICAL TECHNOLOGIES IN THE BIOMEDICAL AND LIFE SCIENCES, 2017, 1047 : 215 - 222
  • [50] Development and validation of a liquid chromatography with tandem mass spectrometry method for the quantification of vitisin B in rat plasma and urine
    Choi, Woong-Kee
    Yoon, Kee Dong
    Lee, Joeng Kee
    Park, Jung Bae
    Heo, Tae-Hwe
    Lee, Choongho
    Bae, Soo Kyung