Development and Validation of Liquid Chromatography-Tandem Mass Spectrometric Method for the Quantification of Diclofenac in Human Plasma

被引:0
|
作者
Grover, Parul [1 ]
Bhardwaj, Monika [2 ]
Mehta, L. [3 ]
Kumar, Sandeep [4 ]
机构
[1] Delhi NCR, KIET Grp Inst, KIET Sch Pharm, Ghaziabad 201206, Uttar Pradesh, India
[2] Indian Inst Integrat Med, Nat Prod Chem Div, Canal Rd, Jammu 180001, Jammu And Kashm, India
[3] Amity Univ, Amity Inst Pharm, Noida 201301, Uttar Pradesh, India
[4] Natl Inst Pharmaceut Educ & Res, Dept Regulatory Affairs, Hyderabad 500037, Telangana, India
关键词
Diclofenac; validation; liquid chromatography-tandem mass spectrophotometry; human; plasma; multiple reaction monitoring; pharmacokinetics; HPLC METHOD; PERFORMANCE; SODIUM;
D O I
暂无
中图分类号
R9 [药学];
学科分类号
1007 ;
摘要
According to Food and Drug Administration requirements, a simple, sensitive and specific liquid chromatography-tandem mass spectrophotometry method for quantifying diclofenac in human plasma was developed and fully validated. Electrospray ionisation in the positive mode produced protonated ions, which were utilised to detect analyte and fluconazole (internal standard). Protein precipitation generated by acetonitrile was used to extract the analytes, followed by liquid-liquid extraction with ethyl acetate. The reversed phase separation was performed on a Chromolith speed ROD RP-18e (4.6 mmx50 mm) column with a simple isocratic mobile phase of 10 mM ammonium acetate in water, pH adjusted to 4.5 using acetic acid:acetonitrile in the ratio of (20:80, v/v) at a flow rate of 0.5 ml min-1. On a triple quadrupole mass spectrometer, fragmentation of Diclofenac m/z 296.10- (parent) and 250 (product) and Fluconazole m/z 307.20- (parent) and 220 (product) for internal standard was monitored. The devised method was verified in human plasma spanning a concentration range of 18.75 to 2000.25 ng ml-1, with a correlation coefficient (r2) of 0.9948. The detection was carried out using an electrospray ionisation approach on a triple quadrupole mass spectrometer that was used for multiple reaction monitoring. The intraday precision and accuracy values obtained from six different sets of quality control samples evaluated on different occasions ranged from 96.22-113.46 % and 2.66-9.95 %, respectively. For the analyte and internal standard, the overall recoveries were 61.98 3.97 and 55.01 1.18, respectively. The described approach was used to analyse diclofenac in human plasma samples with great performance.
引用
收藏
页码:740 / 752
页数:13
相关论文
共 50 条
  • [21] Development and Validation of Liquid Chromatography-Tandem Mass Spectrometry Method for Quantification of Plasma Metanephrines for Differential Diagnosis of Adrenal Incidentaloma
    Lee, Sae-Mi
    Lee, Mi-Na
    Oh, Hyeon Ju
    Cho, Yoon Young
    Kim, Jae Hyeon
    Woo, Hye In
    Park, Hyung-Doo
    Lee, Soo-Youn
    ANNALS OF LABORATORY MEDICINE, 2015, 35 (05) : 519 - 522
  • [22] Solid phase extraction and quantification of diclofenac sodium in human plasma by liquid chromatography-tandem mass spectrometry
    Nalini Kanta Sahoo
    Madhusmita Sahu
    Podilapu Srinivasa Rao
    Goutam Ghosh
    Journal of Analytical Chemistry, 2015, 70 : 424 - 430
  • [23] Solid phase extraction and quantification of diclofenac sodium in human plasma by liquid chromatography-tandem mass spectrometry
    Sahoo, Nalini Kanta
    Sahu, Madhusmita
    Rao, Podilapu Srinivasa
    Ghosh, Goutam
    JOURNAL OF ANALYTICAL CHEMISTRY, 2015, 70 (04) : 424 - 430
  • [24] Simultaneous determination of raltegravir and raltegravir glucuronide in human plasma by liquid chromatography-tandem mass spectrometric method
    Wang, Ling-Zhi
    Lee, Lawrence Soon-U
    Thuya, Win-Lwin
    Soon, Gaik Hong
    Kong, Li-Ren
    Nye, Pei-Ling
    Lee, Edmund Jon Deoon
    Flexner, Charles
    Goh, Boon-Cher
    JOURNAL OF MASS SPECTROMETRY, 2011, 46 (02): : 202 - 208
  • [25] Bioanalytical method development, validation and quantification of flupirtine maleate in rat plasma by liquid chromatography-tandem mass spectrometry
    Kandasamy, Karthikeyan
    Gowdra, Vasantharaju Surenahalli
    Nammalvar, Hariprabhu
    Govindarajan, Arul Kumaran Kottur S.
    ARZNEIMITTELFORSCHUNG-DRUG RESEARCH, 2011, 61 (12): : 693 - 699
  • [26] Development and Validation of a Rapid High-Performance Liquid Chromatography-Tandem Mass Spectrometric Method for Determination of Folic Acid in Human Plasma
    Zayed, Aref
    Bustami, Rana
    Alabsi, Wafaa
    El-Elimat, Tamam
    PHARMACEUTICALS, 2018, 11 (02)
  • [27] Development and validation of liquid chromatography-tandem mass spectrometric method for simultaneous determination of fosinopril and its active metabolite fosinoprilat in human plasma
    Cui Shuangjin
    Fang, Feng
    Ming, Ma
    Han, Liu
    Yun, Chen
    JOURNAL OF CHROMATOGRAPHY B-ANALYTICAL TECHNOLOGIES IN THE BIOMEDICAL AND LIFE SCIENCES, 2007, 854 (1-2): : 143 - 151
  • [28] Development of a sensitive liquid chromatography-tandem mass spectrometry method for quantification of human plasma arginine vasopressin
    Takiwaki, Masaki
    Nomura, Fumio
    Satoh, Mamoru
    Tsuchida, Sachio
    Otake, Kazuo
    Takagi, Junko
    JOURNAL OF CHROMATOGRAPHY B-ANALYTICAL TECHNOLOGIES IN THE BIOMEDICAL AND LIFE SCIENCES, 2021, 1181
  • [29] A validated method for the quantification of fosfomycin in human plasma by liquid chromatography-tandem mass spectrometry
    Martens-Lobenhoffer, Jens
    Bode-Boeger, Stefanie M.
    JOURNAL OF CHROMATOGRAPHY B-ANALYTICAL TECHNOLOGIES IN THE BIOMEDICAL AND LIFE SCIENCES, 2015, 990 : 164 - 168
  • [30] Bioanalytical method development and validation of a liquid chromatography-tandem mass spectrometry method for determination of β-lapachone in human plasma
    Putnam, William C.
    Kallem, Raja Reddy
    Subramaniyan, Indhumathy
    Beg, M. Shaalan
    Edpuganti, Vindhya
    JOURNAL OF PHARMACEUTICAL AND BIOMEDICAL ANALYSIS, 2020, 188