Development and Validation of Liquid Chromatography-Tandem Mass Spectrometric Method for the Quantification of Diclofenac in Human Plasma

被引:0
作者
Grover, Parul [1 ]
Bhardwaj, Monika [2 ]
Mehta, L. [3 ]
Kumar, Sandeep [4 ]
机构
[1] Delhi NCR, KIET Grp Inst, KIET Sch Pharm, Ghaziabad 201206, Uttar Pradesh, India
[2] Indian Inst Integrat Med, Nat Prod Chem Div, Canal Rd, Jammu 180001, Jammu And Kashm, India
[3] Amity Univ, Amity Inst Pharm, Noida 201301, Uttar Pradesh, India
[4] Natl Inst Pharmaceut Educ & Res, Dept Regulatory Affairs, Hyderabad 500037, Telangana, India
关键词
Diclofenac; validation; liquid chromatography-tandem mass spectrophotometry; human; plasma; multiple reaction monitoring; pharmacokinetics; HPLC METHOD; PERFORMANCE; SODIUM;
D O I
暂无
中图分类号
R9 [药学];
学科分类号
1007 ;
摘要
According to Food and Drug Administration requirements, a simple, sensitive and specific liquid chromatography-tandem mass spectrophotometry method for quantifying diclofenac in human plasma was developed and fully validated. Electrospray ionisation in the positive mode produced protonated ions, which were utilised to detect analyte and fluconazole (internal standard). Protein precipitation generated by acetonitrile was used to extract the analytes, followed by liquid-liquid extraction with ethyl acetate. The reversed phase separation was performed on a Chromolith speed ROD RP-18e (4.6 mmx50 mm) column with a simple isocratic mobile phase of 10 mM ammonium acetate in water, pH adjusted to 4.5 using acetic acid:acetonitrile in the ratio of (20:80, v/v) at a flow rate of 0.5 ml min-1. On a triple quadrupole mass spectrometer, fragmentation of Diclofenac m/z 296.10- (parent) and 250 (product) and Fluconazole m/z 307.20- (parent) and 220 (product) for internal standard was monitored. The devised method was verified in human plasma spanning a concentration range of 18.75 to 2000.25 ng ml-1, with a correlation coefficient (r2) of 0.9948. The detection was carried out using an electrospray ionisation approach on a triple quadrupole mass spectrometer that was used for multiple reaction monitoring. The intraday precision and accuracy values obtained from six different sets of quality control samples evaluated on different occasions ranged from 96.22-113.46 % and 2.66-9.95 %, respectively. For the analyte and internal standard, the overall recoveries were 61.98 3.97 and 55.01 1.18, respectively. The described approach was used to analyse diclofenac in human plasma samples with great performance.
引用
收藏
页码:740 / 752
页数:13
相关论文
共 23 条
[1]   HIGH-PERFORMANCE LIQUID-CHROMATOGRAPHIC DETERMINATION OF NAPROXEN, IBUPROFEN AND DICLOFENAC IN PLASMA AND SYNOVIAL-FLUID IN MAN [J].
BLAGBROUGH, IS ;
DAYKIN, MM ;
DOHERTY, M ;
PATTRICK, M ;
SHAW, PN .
JOURNAL OF CHROMATOGRAPHY-BIOMEDICAL APPLICATIONS, 1992, 578 (02) :251-257
[2]   System suitability in bioanalytical LC/MS/MS [J].
Briscoe, Chad J. ;
Stiles, Mark R. ;
Hage, David S. .
JOURNAL OF PHARMACEUTICAL AND BIOMEDICAL ANALYSIS, 2007, 44 (02) :484-491
[3]   Simultaneous Determination of Diclofenac Potassium and Drotaverine Hydrochloride in Human Plasma using Reversed-Phase High-Performance Liquid Chromatography [J].
Dahivelkar, Prasad P. ;
Bhoir, Suvarna I. ;
Bari, Sanjay B. ;
Surana, Sanjay J. ;
Bhagwat, Ashok M. .
JOURNAL OF CHROMATOGRAPHIC SCIENCE, 2012, 50 (08) :694-701
[4]   Clinical pharmacokinetics of diclofenac - Therapeutic insights and pitfalls [J].
Davies, NM ;
Anderson, KE .
CLINICAL PHARMACOKINETICS, 1997, 33 (03) :184-213
[5]  
Davies NM, 2000, J PHARM PHARM SCI, V3, P137
[6]   UPLC-MS/MS Determination of Aceclofenac and Diclofenac in Bulk, Dosage forms and in At-line Monitoring of Aceclofenac Synthesis [J].
El-Bagary, Ramzia I. ;
Azzazy, Hassan M. E. ;
ElKady, Ehab F. ;
Farouk, Faten .
BRITISH JOURNAL OF PHARMACEUTICAL RESEARCH, 2014, 4 (11) :1311-1331
[7]   A RAPID AND SENSITIVE BIOANALYTICAL HPLC METHOD FOR DETERMINING DICLOFENAC SODIUM IN HUMAN PLASMA FOR BIOEQUIVALENCE STUDIES [J].
Emara, Laila H. ;
Taha, Nesrin F. ;
El-Ashmawy, Ahmed A. ;
Raslan, Hala M. ;
Mursi, Nadia M. .
JOURNAL OF LIQUID CHROMATOGRAPHY & RELATED TECHNOLOGIES, 2012, 35 (15) :2203-2216
[8]  
European Medicines Agency, 2012, Guideline on bioanalytical method validation, V44, P1
[9]   Nonsteroidal antiinflammatory drugs and the small intestine [J].
Fortun, PJ ;
Hawkey, CJ .
CURRENT OPINION IN GASTROENTEROLOGY, 2005, 21 (02) :169-175
[10]   Identification and Characterization of in vitro Metabolites of Belinostat by Rat Liver Microsomes using Ultra Performance Liquid Chromatography Coupled with Tandem Mass Spectrometry [J].
Grover, Parul ;
Mehta, Lovekesh ;
Naved, Tanveer ;
Kumar, Sandeep ;
Monga, Gorav .
INDIAN JOURNAL OF PHARMACEUTICAL EDUCATION AND RESEARCH, 2022, 56 (01) :S58-S66