Carbon screen-printed electrodes modified by a polycatechol film for Cu and Pb detection in acidified drinking water

被引:2
|
作者
Parat, Corinne [1 ]
Ricard, Estelle [1 ]
Ben Mefteh, Wahid [1 ]
Le Hecho, Isabelle [1 ]
机构
[1] Univ Pau & Pays Adour, Inst Sci Analyt Environm & Mat, CNRS, UMR5254,UPPA E2S, 2 Ave Pierre Angot, F-64000 Pau, France
关键词
Electropolymerisation; In situ detection; Trace metals; Stripping chronopotentiometry; ANODIC-STRIPPING VOLTAMMETRY; HEAVY-METAL IONS; ELECTROCHEMICAL SENSORS; SPECIATION; CADMIUM; PYROCATECHOL; OXIDATION; FEATURES;
D O I
10.1016/j.electacta.2023.142666
中图分类号
O646 [电化学、电解、磁化学];
学科分类号
081704 ;
摘要
The dissolution of metals such as Cu or Pb in water can be increased by prolonged stagnation of water in internal pipes of drinking water networks, resulting in high concentrations in the consumer's tap water. As they can accumulate in biota and affect living organisms with more or less serious long-term toxic effects, the monitoring of Cu or Pb in tap water and more generally in aquatic environments is therefore an important issue. For this purpose, a new electrochemical sensor based on a screen-printed carbon electrode modified with a polycatechol film was developed for the highly sensitive detection of Cu and Pb in drinking water. The electropolymerisation was first optimised to obtain a homogeneous and reproducible film for the detection of trace metals. The mechanism of the polymerization process was proposed and discussed. Then, the performance of the new sensor was evaluated. The pH and the conductivity were found to be the main parameters influencing the sensitivity of the sensors. Thus, the electrochemical analyses carried out at pH values around neutrality with this device made it possible to determine the free and labile forms of metal in solution, while the total metal contents were determined after acidification of water samples to pH 5 or less. Furthermore, a stable signal was obtained from 470 & mu;S cm- 1, which means that most of freshwater rivers and mineral waters can be directly analysed without any supporting electrolyte addition. After optimisation of the analytical conditions, a sensitivity of the order of & mu;g L-1 was reached for a deposition time of 60s while an electrodeposition time of 300s gave a sensitivity of ng L-1.
引用
收藏
页数:9
相关论文
共 50 条
  • [1] CHEMICALLY MODIFIED, SCREEN-PRINTED CARBON ELECTRODES
    WRING, SA
    HART, JP
    ANALYST, 1992, 117 (08) : 1281 - 1286
  • [2] Modified Gold Screen-Printed Electrodes for the Determination of Heavy Metals
    Celesti, Consuelo
    Giofre, Salvatore Vincenzo
    Espro, Claudia
    Legnani, Laura
    Neri, Giovanni
    Iannazzo, Daniela
    SENSORS, 2024, 24 (15)
  • [3] 4-ethyphenol detection in wine by fullerene modified screen-printed carbon electrodes
    Portugal-Gomez, Paula
    Asuncion Alonso-Lomillo, M.
    Dominguez-Renedo, Olga
    MICROCHEMICAL JOURNAL, 2022, 180
  • [4] Screen-Printed Sensors Modified with Nafion and Mesoporous Carbon for Electrochemical Detection of Lead in Blood
    Boselli, Elena
    Wu, Zhizhen
    Haynes, Erin N.
    Papautsky, Ian
    JOURNAL OF THE ELECTROCHEMICAL SOCIETY, 2024, 171 (02)
  • [5] Screen-printed carbon electrodes modified with a bismuth film for stripping voltammetric analysis of platinum group metals in environmental samples
    Silwana, Bongiwe
    van der Horst, Charlton
    Iwuoha, Emmanuel
    Somerset, Vernon
    ELECTROCHIMICA ACTA, 2014, 128 : 119 - 127
  • [6] A screen-printed carbon electrode modified with a bismuth film and gold nanoparticles for simultaneous stripping voltammetric determination of Zn(II), Pb(II) and Cu(II)
    Lu, Zhiwei
    Zhang, Junjun
    Dai, Wanlin
    Lin, Xueni
    Ye, Jiaping
    Ye, Jianshan
    MICROCHIMICA ACTA, 2017, 184 (12) : 4731 - 4740
  • [7] Detection of cadmium content of lily by carbon nanoparticles modified screen-printed electrode
    Zheng, Qiqi
    Yu, Yonghua
    Wu, Jian
    Nongye Gongcheng Xuebao/Transactions of the Chinese Society of Agricultural Engineering, 2015, 31 (20): : 275 - 280
  • [8] Determination of Arsenic(III) Using Platinum Nanoparticle-Modified Screen-Printed Carbon-Based Electrodes
    Sanllorente-Mendez, Silvia
    Dominguez-Renedo, Olga
    Arcos-Martinez, M. Julia
    ELECTROANALYSIS, 2009, 21 (3-5) : 635 - 639
  • [9] Selective detection of dopamine in the presence of ascorbic acid using carbon nanotube modified screen-printed electrodes
    Moreno, Monica
    Sanchez Arribas, Alberto
    Bermejo, Esperanza
    Chicharro, Manuel
    Zapardiel, Antonio
    Rodriguez, Marcela C.
    Jalit, Yamile
    Rivas, Gustavo A.
    TALANTA, 2010, 80 (05) : 2149 - 2156
  • [10] Part I: A comparative study of bismuth-modified screen-printed electrodes for lead detection
    Quintana, Josefina Calvo
    Arduini, Fabiana
    Arnine, Aziz
    Punzo, Francesco
    Li Destri, Giovanni
    Bianchini, Chiara
    Zane, Daniela
    Curulli, Antonella
    Palleschi, Giuseppe
    Moscone, Danila
    ANALYTICA CHIMICA ACTA, 2011, 707 (01) : 171 - 177