End-of-pipe treatment of secondary treated coke-oven wastewater for removal of fluoride, cyanide, phenol, ammoniacal-N and nitrate using waste material: Experiment, modelling and optimization

被引:6
|
作者
Bishayee, Bhaskar [1 ]
Rai, Abhilasha [1 ]
Kumar, Abhay [2 ]
Kamila, Biswajit [1 ]
Ruj, Biswajit [3 ]
Dutta, Susmita [1 ]
机构
[1] Natl Inst Technol Durgapur, Dept Chem Engn, Durgapur 713209, India
[2] Natl Inst Technol Durgapur, Earth & Environm Studies, Durgapur 713209, India
[3] CSIR Cent Mech Engn Res Inst, Environm Engn Grp, Durgapur 713209, India
来源
关键词
Coke -oven wastewater; Earthen Tea Pots; Adsorption; Modelling and optimization; End -of -pipe treatment; RESPONSE-SURFACE METHODOLOGY; ADSORPTIVE REMOVAL; AQUEOUS-SOLUTION; METHYLENE-BLUE; ISOTHERM; IRON; ACID;
D O I
10.1016/j.cherd.2023.04.047
中图分类号
TQ [化学工业];
学科分类号
0817 ;
摘要
The present investigation focused on End-of-pipe treatment of secondary treated cokeoven wastewater to remove cyanide, phenol, ammoniacal-N, nitrate and fluoride using earthen tea pot (ETP), a local market waste. The effect of parameters like adsorption time (0-10 h), particle size (1-3 mm) and adsorbent dose (10-30 gL-1) was tested for removal of pollutants from synthetic BOD treated coke-oven wastewater (SBTCW) and maximum removal was obtained as cyanide (95.46 +/- 0.004%), phenol (99.70 +/- 0.005%), ammoniacalN (47.88 +/- 6.31%), nitrate (61.03 +/- 2.12%), and fluoride (92.35 +/- 0.09%) at adsorption time 10 h, particle size 1 mm and adsorbent dose 10 gL-1. Kinetic study showed that the fluoride removal data fit satisfactorily to the Pseudo 2nd order kinetic model, whereas the Pseudo 1st order model was found to be fitted well to the kinetic data of all other pollutants. Adsorption isotherm study portrayed that the Freundlich isotherm model holds good to represent equilibrium data for the removal of pollutants. Response Surface Methodology (RSM) was used to optimize the removal efficiencies of all five pollutants. The optimum removal condition as shown by RSM study was contact time: 7.3 h, and initial concentrations (ICs) of cyanide, phenol, ammoniacal-N, nitrate and fluoride are 0.71, 10, 400, 100 and 10.1 mgL-1, respectively, and the removal of five pollutants (cyanide, phenol, ammoniacal-N, nitrate and fluoride) were predicted as 40.58%, 90.00%, 41.63%, 96.00% and 45.29%, respectively. Artificial Neural Network model was developed based on experimental points which indicated that the model can calculate abatement of five different pollutants for various operating conditions with reasonably high accuracy. Genetic Algorithm was then used to optimize the removal process of the five pollutants. Regeneration study was conducted to assess the efficacy of the regenerated adsorbent in next cycle of the End-of-pipe treatment of SBTCW. Finally, real secondary treated coke -oven wastewater was collected and treated with the present adsorbent. (c) 2023 Institution of Chemical Engineers. Published by Elsevier Ltd. All rights reserved.
引用
收藏
页码:439 / 460
页数:22
相关论文
共 4 条
  • [1] Application of Cyanobacterial Consortium to Remove Ammoniacal-N, Phenol, and Nitrate from Synthetic Coke-Oven Wastewater as Tertiary Treatment
    Rai, Abhilasha
    Wadhwa, Gurpreet Kaur
    Chakrabarty, Jitamanyu
    Dutta, Susmita
    JOURNAL OF ENVIRONMENTAL ENGINEERING, 2020, 146 (07)
  • [2] Abatement of cyanide and ammoniacal-N from coke-oven wastewater using natural adsorbents: A comparative study
    Sain, Manisha
    Pramanik, Sabyasachi
    Baltrenaite-Gediene, Edita
    Ghanta, Kartik Chandra
    Dutta, Susmita
    JOURNAL OF THE INDIAN CHEMICAL SOCIETY, 2021, 98 (12)
  • [3] Simultaneous Bioremediation of Cyanide, Phenol, and Ammoniacal-N from Synthetic Coke-Oven Wastewater Using Bacillus sp. NITD 19
    Rai, Abhilasha
    Gowrishetty, Karthik Kumar
    Singh, Sunita
    Chakrabarty, Jitamanyu
    Bhattacharya, Pinaki
    Dutta, Susmita
    JOURNAL OF ENVIRONMENTAL ENGINEERING, 2021, 147 (01)
  • [4] Adsorptive removal of phenol from coke-oven wastewater using Gondwana shale, India: experiment, modeling and optimization
    Sadhu, Koushik
    Mukherjee, Ankita
    Shukla, Surya Kumar
    Adhikari, Kalyan
    Dutta, Susmita
    DESALINATION AND WATER TREATMENT, 2014, 52 (34-36) : 6492 - 6504