Impact of coupled heat and moisture transfer on indoor comfort and energy demand for residential buildings in hot-humid regions

被引:15
|
作者
Xia, Dawei [1 ]
Zhong, Zhengnan [1 ]
Huang, Yu [2 ]
Zou, Yukai [1 ]
Lou, Siwei [2 ]
Zhan, Qiaosheng [3 ]
Guo, Jialiang [1 ]
Yang, Jiahao [1 ]
Guo, Tongye [1 ]
机构
[1] Guangzhou Univ, Sch Architecture & Urban Planning, Guangzhou, Guangdong, Peoples R China
[2] Guangzhou Univ, Sch Civil Engn, Guangzhou, Guangdong, Peoples R China
[3] South China Univ Technol, Sch Architecture, Guangzhou, Guangdong, Peoples R China
关键词
Coupled heat and moisture transfer; Hot -humid climate; Residential buildings; Energy demand; Indoor comfort; HYGROTHERMAL BEHAVIOR; MASS-TRANSFER; POROUS-MEDIA; PERFORMANCE; SIMULATION; SYSTEMS; WALL; AIR;
D O I
10.1016/j.enbuild.2023.113029
中图分类号
TU [建筑科学];
学科分类号
0813 ;
摘要
Moisture significantly affects indoor thermal comfort and energy demand. However, the coupled heat and moisture transfer (HAMT) effect inside the wall assemblies is often ignored in building performance calculations. To quantify its impact on building performance under hot and humid climates, the thermal environment and energy demand of an apartment in Guangzhou (China) were evaluated with and without HAMT finite element algorithm, respectively. The HAMT effects are quantified and analyzed in different periods. Different boundary conditions regarding climate uncertainty, wind-driven rain effect, and wall solar absorptance are considered. The results show that under naturally ventilated conditions, ignoring the effect of HAMT in walls can lead to an overestimation of indoor operative temperature by 1.2 degrees C in summer and an underestimation of 1.7 degrees C in winter. The deviation in indoor operative temperature calculated by the two models is noticeable from noon to midnight. On the other hand, cooling and dehumidification demand energy demand can be underestimated by 8.4% and 12.4%, respectively, without consideration of HAMT. The HAMT also increases the probability of high hourly energy demand for cooling and dehumidification under the HAMT effect. These findings emphasize the importance of considering the HAMT effect when evaluating building performance in hot and humid regions. (c) 2023 Elsevier B.V. All rights reserved.
引用
收藏
页数:18
相关论文
共 41 条
  • [1] Indoor thermal comfort for residential buildings in the hot-humid climate of Nigeria during the dry season
    Adaji, Michael U.
    Watkins, Richard
    Adler, Gerald
    Proceedings of 33rd PLEA International Conference: Design to Thrive, PLEA 2017, 2017, 1 : 949 - 956
  • [2] Application of natural ventilation of residential buildings in hot-humid regions
    喻伟
    沈艳
    丁勇
    JournalofCentralSouthUniversityofTechnology, 2009, 16(S1) (S1) : 68 - 74
  • [3] Application of natural ventilation of residential buildings in hot-humid regions
    Yu Wei
    Shen Yan
    Ding Yong
    JOURNAL OF CENTRAL SOUTH UNIVERSITY OF TECHNOLOGY, 2009, 16 : 68 - 74
  • [4] Application of natural ventilation of residential buildings in hot-humid regions
    喻伟
    沈艳
    丁勇
    Journal of Central South University, 2009, 16 (S1) : 68 - 74
  • [5] Field study of thermal comfort in residential buildings in the equatorial hot-humid climate of Malaysia
    Djamila, Harimi
    Chu, Chi-Ming
    Kumaresan, Sivakumar
    BUILDING AND ENVIRONMENT, 2013, 62 : 133 - 142
  • [6] Improving the Energy Performance and Economic Benefits of Aged Residential Buildings by Retrofitting in Hot-Humid Regions of China
    Yang, Xiaolin
    Chen, Zhuoxi
    Zou, Yukai
    Wan, Fengdeng
    ENERGIES, 2023, 16 (13)
  • [7] Influence of view factors on outdoor thermal comfort of residential areas in hot-humid regions
    Li, Li
    Hong, Jiayi
    Ma, Mingtao
    Fan, Chengliang
    Xiong, Xiu
    Pang, Yue
    INTERNATIONAL JOURNAL OF BIOMETEOROLOGY, 2025, 69 (01) : 261 - 274
  • [8] Cooling Energy Challenges in Residential Buildings During Heat Waves: Urban Heat Island Impacts in a Hot-Humid City
    Zou, Yukai
    Wu, Zhuotong
    Li, Binbin
    Jia, Yudong
    BUILDINGS, 2024, 14 (12)
  • [9] The effects of night ventilation technique on indoor thermal environment for residential buildings in hot-humid climate of Malaysia
    Kubota, Tetsu
    Chyee, Doris Toe Hooi
    Ahmad, Supian
    ENERGY AND BUILDINGS, 2009, 41 (08) : 829 - 839
  • [10] IMPACT OF COUPLED HEAT AND MOISTURE TRANSFER EFFECTS ON BUILDINGS ENERGY CONSUMPTION
    Ferroukhi, Mohammed Yacine
    Belarbi, Rafik
    Limam, Karim
    Bosschaerts, Walter
    THERMAL SCIENCE, 2017, 21 (03): : 1359 - 1368