Clinical application of 3D-printed biodegradable lumbar interbody cage (polycaprolactone/β-tricalcium phosphate) for posterior lumbar interbody fusion

被引:8
作者
Liu, Yichao [1 ]
Wu, Hao [2 ]
Bao, Shusen [2 ]
Huang, Hai [2 ]
Tang, Zhen [2 ]
Dong, Hui [2 ]
Liu, Jiaqi [3 ]
Chen, Shengxiu [3 ]
Wang, Ning [2 ]
Wu, Zhigang [1 ]
Zhang, Zhiyong [4 ]
Shi, Lei [1 ,5 ]
Li, Xiaokang [2 ,6 ]
Guo, Zheng [2 ,6 ]
机构
[1] Fourth Mil Med Univ, Xijing Hosp, Dept Orthopaed, Xian, Shaanxi, Peoples R China
[2] Fourth Mil Med Univ, Tangdu Hosp, Dept Orthopaed, Xian, Shaanxi, Peoples R China
[3] Fourth Mil Med Univ, Student Brigade Basic Med Sch, Xian, Shaanxi, Peoples R China
[4] Guangzhou Med Univ, Affiliated Hosp 3, Ctr Translat Res Regenerat Med, Guangzhou, Guangdong, Peoples R China
[5] Fourth Mil Med Univ, Xijing Hosp, Dept Orthopaed, Xian 710032, Shaanxi, Peoples R China
[6] Fourth Mil Med Univ, Tangdu Hosp, Dept Orthopaed, Xian 710038, Shaanxi, Peoples R China
基金
中国国家自然科学基金;
关键词
3D printed; biodegradable; cage; clinical trial; lumbar interbody fusion; polycaprolactone (PCL); beta-tricalcium phosphate (beta-TCP); PEEK CAGES; SCAFFOLD; TCP; IMPLANTS;
D O I
10.1002/jbm.b.35244
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
A novel 3D-printed biodegradable cage composed of polycaprolactone (PCL) and beta-tricalcium phosphate (beta-TCP) in a mass ratio of 50:50, with stable resorption patterns and mechanical strength has been developed for lumbar interbody fusion. This is a prospective cohort study to evaluate the short- and mid-term safety and efficacy of this biodegradable cage in posterior lumbar interbody fusion (PLIF) surgery. This was a prospective single-arm pilot clinical trial in 22 patients with a follow-up time of 1, 3, 6, and 12 months, postoperatively. Clinical outcomes were assessed using the Japanese Orthopedic Association Back Pain Evaluation Questionnaire (JOABPEQ) and Visual analogue scale (VAS) for leg pain and low back pain. Radiological examination included X-ray, CT scan, and three-dimensional reconstruction to evaluate surgical indications, intervertebral space height (ISH), intervertebral bone fusion and cage degradation. A total of 22 patients was included, with an average age of 53.5 years. Among 22 patients, one patient lost to follow-up and one patient withdrew from the clinical trial because of cage retropulsion. The remaining 20 patients showed significant improvement in clinical and imaging outcomes compared to the preoperative period. The overall mean VAS for back decreased from 5.85 +/- 0.99 preoperatively to 1.15 +/- 0.86 at the 12-month follow-up (p < .001); the VAS for leg decreased from 5.75 +/- 1.11 to 1.05 +/- 0.76 (p < .001); the JOA score improved from 13.8 +/- 2.64 to 26.45 +/- 2.46 (p < .001). The mean intervertebral space height (ISH) increased from 11.01 +/- 1.75 mm preoperatively to 12.67 +/- 1.89 mm at the 12-month follow-up and the bone fusion reached 95.2% (20/21 disc segments). Partial resorption (inferior to 50% compared with the initial cage size) were found in all cages (21/21). The clinical and radiological assessments showed that the application of 3D-printed biodegradable PCL/beta-TCP cages in PLIF yielded satisfactory results at the 12-month follow-up. In the future, long-term clinical observations and controlled clinical trials are required to further validate the safety and efficacy of this novel cage.
引用
收藏
页码:1398 / 1406
页数:9
相关论文
共 38 条
[1]   Early Outcomes of Three-Dimensional-Printed Porous Titanium versus Polyetheretherketone Cage Implantation for Stand-Alone Lateral Lumbar Interbody Fusion in the Treatment of Symptomatic Adjacent Segment Degeneration [J].
Amini, Dominik Adl ;
Moser, Manuel ;
Oezel, Lisa ;
Zhu, Jiaqi ;
Okano, Ichiro ;
Shue, Jennifer ;
Sama, Andrew A. ;
Cammisa, Frank P. ;
Girardi, Federico P. ;
Hughes, Alexander P. .
WORLD NEUROSURGERY, 2022, 162 :E14-E20
[2]   Development and mechanical characterization of porous titanium bone substitutes [J].
Barbas, A. ;
Bonnet, A. -S. ;
Lipinski, P. ;
Pesci, R. ;
Dubois, G. .
JOURNAL OF THE MECHANICAL BEHAVIOR OF BIOMEDICAL MATERIALS, 2012, 9 :34-44
[3]   Bioabsorbable self-retaining PLA/nano-sized β-TCP cervical spine interbody fusion cage in goat models: an in vivo study [J].
Cao, Lu ;
Chen, Qian ;
Jiang, Li-Bo ;
Yin, Xiao-Fan ;
Bian, Chong ;
Wang, Hui-Ren ;
Ma, Yi-Qun ;
Li, Xiang-Qian ;
Li, Xi-Lei ;
Dong, Jian .
INTERNATIONAL JOURNAL OF NANOMEDICINE, 2017, 12 :7197-7205
[4]  
Chen CM., 2021, POLYMERS-BASEL, V13
[5]   Instrumented transforaminal lumbar interbody fusion with bioresorbable polymer implants and iliac crest autograft [J].
Coe, JD ;
Vaccaro, AR .
SPINE, 2005, 30 (17) :S76-S83
[6]   PEEK versus metal cages in posterior lumbar interbody fusion: a clinical and radiological comparative study [J].
Cuzzocrea F. ;
Ivone A. ;
Jannelli E. ;
Fioruzzi A. ;
Ferranti E. ;
Vanelli R. ;
Benazzo F. .
MUSCULOSKELETAL SURGERY, 2019, 103 (3) :237-241
[7]   Anterior cervical fusion with a bio-resorbable composite cage (beta TCP-PLLA): clinical and radiological results from a prospective study on 20 patients [J].
Debusscher, F. ;
Aunoble, S. ;
Alsawad, Y. ;
Clement, D. ;
Le Huec, Jean-Charles .
EUROPEAN SPINE JOURNAL, 2009, 18 (09) :1314-1320
[8]   Osteolysis following resorbable poly-l-lactide-co-d, l-lactide PLIF cage use: a review of cases [J].
Frost, Andrew ;
Bagouri, Elmanzour ;
Brown, Mark ;
Jasani, Vinay .
EUROPEAN SPINE JOURNAL, 2012, 21 (03) :449-454
[9]  
HUSKISSON EC, 1974, LANCET, V2, P1127, DOI 10.1016/S0140-6736(74)90884-8
[10]  
Jeong WS., 2022, POLYMERS-BASEL, V14