Behavior of GFRP tube confined hollow high-strength concrete short columns under axial compression

被引:9
作者
Yang, Zhijian [1 ]
Xu, Cong [1 ]
Li, Guochang [1 ]
机构
[1] Shenyang Jianzhu Univ, Sch Civil Engn, Shenyang, Peoples R China
基金
中国国家自然科学基金;
关键词
GFRP tube; Prestressed high strength concrete pipe piles; Hollow concrete column; Axial compression; Finite element analysis; STRESS-STRAIN MODEL; FRP; PERFORMANCE; AGGREGATE;
D O I
10.1016/j.istruc.2024.106017
中图分类号
TU [建筑科学];
学科分类号
0813 ;
摘要
Aiming to improve the corrosion resistance of pile foundations in sea-crossing bridges and coastal projects, a new type of glass fiber reinforced plastic(GFRP) tube confined hollow high-strength concrete (GCHHC) structure is formed by placing Prestressed high strength concrete(PHC) pipe columns inside GFRP tubes and casting highstrength interlayer concrete between them. Existing research on GFRP tube hollow concrete structures is relatively small, and most of the concrete strength is less than 60 MPa. This paper presents the axial compression tests of 6 GCHHC short columns with 3 different GFRP tube thicknesses in the range of 4 mm similar to 8 mm, the effect of the configuration of ordinary reinforcement or not in the PHC tubes columns is also examined. In this paper, the main performance aspects evaluated were the test phenomena, damage patterns, load-displacement curves and load-strain curves of the specimens. The test results show that GCHHCs have high load carrying capacity and axial deformation capacity. The specimens showed two damage modes and were closely related to the GFRP tube thickness. Increasing the thickness of GFRP tubes can significantly improve the axial compressive load carrying capacity and axial deformation capacity of the combined column. The validated finite element model is used to analyze the parameters such as the thickness of GFRP tube, the diameter of common reinforcement, and the strength of sandwich concrete, and it is found that the thickness of GFRP tube is the main parameter affecting the axial compressive load carrying capacity of the combined column. Finally, the axial compressive load capacity calculation formula for the combined column is established based on the limit equilibrium method, and its applicability is examined.
引用
收藏
页数:15
相关论文
共 50 条
[1]  
[Anonymous], 2017, GUIDE DESIGN CONSTRU
[2]   Performance of polypropylene fiber reinforced concrete-filled UPVC tube columns under axial compression [J].
Askari, Shahram Mohammad ;
Khaloo, Alireza ;
Borhani, Mohammad Hadi ;
Masoule, Mohammad Sadegh Tale .
CONSTRUCTION AND BUILDING MATERIALS, 2020, 231
[3]   Unified model for hollow columns externally confined by FRP [J].
Cascardi, Alessio ;
Micelli, Francesco ;
Aiello, Maria Antonietta .
ENGINEERING STRUCTURES, 2016, 111 :119-130
[4]  
CEB-FIP, 1993, Design of Concrete Structures: CEB-FIP Model Code 1990
[5]   Mechanical performance of ocean concrete-filled circular CFRP-steel tube columns under axial compression [J].
Chen, Zongping ;
Pang, Yunsheng ;
Xu, Ruitian ;
Zhou, Ji ;
Xu, Weisheng .
JOURNAL OF CONSTRUCTIONAL STEEL RESEARCH, 2022, 198
[6]   Bond behavior between basalt fiber-reinforced polymer rebars and coral-reef-sand concrete conditioned in saline solution [J].
Ding, Lining ;
Shi, Jianzhe ;
Wang, Xin ;
Liu, Ying ;
Jin, Yundong ;
Wu, Zhishen .
STRUCTURAL CONCRETE, 2020, 21 (02) :659-672
[7]   A review of the research and application progress of new types of concrete-filled FRP tubular members [J].
Dong, Zhiqiang ;
Han, Tianhao ;
Zhang, Bai ;
Zhu, Hong ;
Wu, Gang ;
Wei, Yang ;
Zhang, Pu .
CONSTRUCTION AND BUILDING MATERIALS, 2021, 312
[8]  
[杜新喜 Du Xinxi], 2018, [工程力学, Engineering Mechanics], V35, P71
[9]   Analytical model for FRP-confined circular reinforced concrete columns [J].
Eid, R. ;
Paultre, P. .
JOURNAL OF COMPOSITES FOR CONSTRUCTION, 2008, 12 (05) :541-552
[10]   Experimental Investigation and Design of Hollow Section, Centrifugal Concrete-Filled GFRP Tube Columns [J].
Feng, Bing ;
Zhu, Ya-Hui ;
Xie, Fang ;
Chen, Ju ;
Liu, Cheng-Bin .
BUILDINGS, 2021, 11 (12)