Propagation-based phase-contrast imaging of the breast: image quality and the effect of X-ray energy and radiation dose

被引:1
|
作者
Gunaseelan, Indusaa [1 ]
Zadeh, Alaleh Amin [2 ,3 ]
Arhatari, Benedicta [4 ]
Maksimenko, Anton [4 ]
Hall, Christopher [4 ]
Hausermann, Daniel [4 ]
Kumar, Beena [5 ]
Fox, Jane [6 ]
Quiney, Harry [7 ]
Lockie, Darren [8 ]
Lewis, Sarah [1 ]
Brennan, Patrick [1 ]
Gureyev, Timur [7 ]
Taba, Seyedamir Tavakoli [1 ]
机构
[1] Univ Sydney, Fac Med & Hlth, Discipline Med Imaging Sci, Camperdown, NSW, Australia
[2] Australian Natl Univ, Sch Phys, Canberra, ACT, Australia
[3] Univ Sydney, Camperdown, NSW, Australia
[4] Australian Natl Sci & Technol Org, Australian Synchrotron, Clayton, Vic, Australia
[5] Monash Hlth, Monash Hlth Pathol, Clayton, Vic, Australia
[6] Monash Univ, Fac Med Nursing & Hlth Sci, Clayton, Vic, Australia
[7] Univ Melbourne, Sch Phys, Parkville, Vic, Australia
[8] Eastern Hlth, Maroondah BreastScreen, Ringwood, Vic, Australia
基金
英国医学研究理事会;
关键词
OPTIMIZATION; TOMOGRAPHY; CT;
D O I
10.1259/bjr.20221189
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Objectives: Propagation-based phase-contrast computed tomography (PB-CT) is a new imaging technique that exploits refractive and absorption properties of X-rays to enhance soft tissue contrast and improve image quality. This study compares image quality of PB-CT and absorption-based CT (AB-CT) for breast imaging while exploring X-ray energy and radiation dose. Methods: Thirty-nine mastectomy samples were scanned at energy levels of 28-34keV using a flat panel detector at radiation dose levels of 4mGy and 2mGy. Image quality was assessed using signal-to-noise ratio (SNR), contrast-to-noise ratio (CNR), spatial resolution (res) and visibility (vis). Statistical analysis was performed to compare PB-CT images against their corresponding AB-CT images scanned at 32keV and 4mGy. Results: The PB-CT images at 4mGy, across nearly all energy levels, demonstrated superior image quality than AB-CT images at the same dose. At some energy levels, the 2mGy PB-CT images also showed better image quality in terms of CNR/Res and vis compared to the 4mGy AB-CT images. At both investigated doses, SNR and SNR/res were found to have a statistically significant difference across all energy levels. The difference in vis was statistically significant at some energy levels. Conclusion: This study demonstrates superior image quality of PB-CT over AB-CT, with X-ray energy playing a crucial role in determining image quality parameters. Advances in knowledge: Our findings reveal that standard dose PB-CT outperforms standard dose AB-CT across all image quality metrics. Additionally, we demonstrate that low dose PB-CT can produce superior images compared to standard dose AB-CT in terms of CNR/Res and vis.
引用
收藏
页数:9
相关论文
共 50 条
  • [21] Improving spatial resolution with an edge-enhancement model for low-dose propagation-based X-ray phase-contrast computed tomography
    Zhang, Lin
    Zhao, Huijuan
    Zhou, Zhongxing
    Jia, Mengyu
    Zhang, Limin
    Jiang, Jingying
    Gao, Feng
    OPTICS EXPRESS, 2021, 29 (23): : 37399 - 37417
  • [22] X-ray phase-contrast imaging of the breast-advances towards clinical implementation
    Auweter, S. D.
    Herzen, J.
    Willner, M.
    Grandl, S.
    Scherer, K.
    Bamberg, F.
    Reiser, M. F.
    Pfeiffer, F.
    Hellerhoff, K.
    BRITISH JOURNAL OF RADIOLOGY, 2014, 87 (1034)
  • [23] High resolution propagation-based lung imaging at clinically relevant X-ray dose levels
    Albers, Jonas
    Wagner, Willi L.
    Fiedler, Mascha O.
    Rothermel, Anne
    Wuennemann, Felix
    Di Lillo, Francesca
    Dreossi, Diego
    Sodini, Nicola
    Baratella, Elisa
    Confalonieri, Marco
    Arfelli, Fulvia
    Kalenka, Armin
    Lotz, Joachim
    Biederer, Juergen
    Wielpuetz, Mark O.
    Kauczor, Hans-Ulrich
    Alves, Frauke
    Tromba, Giuliana
    Dullin, Christian
    SCIENTIFIC REPORTS, 2023, 13 (01)
  • [24] Preliminary demonstration of flexible dual-energy x-ray phase-contrast imaging
    Wang, Shenghao
    Zan, Guibin
    Wang, Qiuping
    Liu, Shijie
    OPTICAL ENGINEERING, 2019, 58 (11)
  • [25] Contrast enhancement of propagation based X-ray phase contrast imaging
    Pan, Adam
    Xu, Ling
    Petruccelli, Jon C.
    Gupta, Rajiv
    Barbastathis, George
    ADVANCES IN COMPUTATIONAL METHODS FOR X-RAY OPTICS III, 2014, 9209
  • [26] Imaging Breast Microcalcifications Using Dark-Field Signal in Propagation-Based Phase-Contrast Tomography
    Aminzadeh, A.
    Arhatari, B. D.
    Maksimenko, A.
    Hall, C. J.
    Hausermann, D.
    Peele, A. G.
    Fox, J.
    Kumar, B.
    Prodanovic, Z.
    Dimmock, M.
    Lockie, D.
    Pavlov, K. M.
    Nesterets, Y., I
    Thompson, D.
    Mayo, S. C.
    Paganin, D. M.
    Taba, S. T.
    Lewis, S.
    Brennan, P. C.
    Quiney, H. M.
    Gureyev, T. E.
    IEEE TRANSACTIONS ON MEDICAL IMAGING, 2022, 41 (11) : 2980 - 2990
  • [27] Phase-contrast x-ray imaging of the breast: recent developments towards clinics
    Coan, P.
    Bravin, A.
    Tromba, G.
    JOURNAL OF PHYSICS D-APPLIED PHYSICS, 2013, 46 (49)
  • [28] X-ray phase-contrast imaging: the quantum perspective
    Slowik, J. M.
    Santra, R.
    JOURNAL OF PHYSICS B-ATOMIC MOLECULAR AND OPTICAL PHYSICS, 2013, 46 (16)
  • [29] Noise in x-ray grating-based phase-contrast imaging
    Weber, Thomas
    Bartl, Peter
    Bayer, Florian
    Durst, Juergen
    Haas, Wilhelm
    Michel, Thilo
    Ritter, Andre
    Anton, Gisela
    MEDICAL PHYSICS, 2011, 38 (07) : 4133 - 4140
  • [30] Propagation based X-ray phase-contrast imaging technique for the microstructure analysis of biological soft tissues
    Wu, Jie
    OPTIK, 2014, 125 (03): : 1062 - 1064