Propagation-based phase-contrast imaging of the breast: image quality and the effect of X-ray energy and radiation dose

被引:1
|
作者
Gunaseelan, Indusaa [1 ]
Zadeh, Alaleh Amin [2 ,3 ]
Arhatari, Benedicta [4 ]
Maksimenko, Anton [4 ]
Hall, Christopher [4 ]
Hausermann, Daniel [4 ]
Kumar, Beena [5 ]
Fox, Jane [6 ]
Quiney, Harry [7 ]
Lockie, Darren [8 ]
Lewis, Sarah [1 ]
Brennan, Patrick [1 ]
Gureyev, Timur [7 ]
Taba, Seyedamir Tavakoli [1 ]
机构
[1] Univ Sydney, Fac Med & Hlth, Discipline Med Imaging Sci, Camperdown, NSW, Australia
[2] Australian Natl Univ, Sch Phys, Canberra, ACT, Australia
[3] Univ Sydney, Camperdown, NSW, Australia
[4] Australian Natl Sci & Technol Org, Australian Synchrotron, Clayton, Vic, Australia
[5] Monash Hlth, Monash Hlth Pathol, Clayton, Vic, Australia
[6] Monash Univ, Fac Med Nursing & Hlth Sci, Clayton, Vic, Australia
[7] Univ Melbourne, Sch Phys, Parkville, Vic, Australia
[8] Eastern Hlth, Maroondah BreastScreen, Ringwood, Vic, Australia
基金
英国医学研究理事会;
关键词
OPTIMIZATION; TOMOGRAPHY; CT;
D O I
10.1259/bjr.20221189
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Objectives: Propagation-based phase-contrast computed tomography (PB-CT) is a new imaging technique that exploits refractive and absorption properties of X-rays to enhance soft tissue contrast and improve image quality. This study compares image quality of PB-CT and absorption-based CT (AB-CT) for breast imaging while exploring X-ray energy and radiation dose. Methods: Thirty-nine mastectomy samples were scanned at energy levels of 28-34keV using a flat panel detector at radiation dose levels of 4mGy and 2mGy. Image quality was assessed using signal-to-noise ratio (SNR), contrast-to-noise ratio (CNR), spatial resolution (res) and visibility (vis). Statistical analysis was performed to compare PB-CT images against their corresponding AB-CT images scanned at 32keV and 4mGy. Results: The PB-CT images at 4mGy, across nearly all energy levels, demonstrated superior image quality than AB-CT images at the same dose. At some energy levels, the 2mGy PB-CT images also showed better image quality in terms of CNR/Res and vis compared to the 4mGy AB-CT images. At both investigated doses, SNR and SNR/res were found to have a statistically significant difference across all energy levels. The difference in vis was statistically significant at some energy levels. Conclusion: This study demonstrates superior image quality of PB-CT over AB-CT, with X-ray energy playing a crucial role in determining image quality parameters. Advances in knowledge: Our findings reveal that standard dose PB-CT outperforms standard dose AB-CT across all image quality metrics. Additionally, we demonstrate that low dose PB-CT can produce superior images compared to standard dose AB-CT in terms of CNR/Res and vis.
引用
收藏
页数:9
相关论文
共 50 条
  • [1] Effect of x-ray energy on the radiological image quality in propagation-based phase-contrast computed tomography of the breast
    Wan, Sarina
    Arhatari, Benedicta D.
    Nesterets, Yakov, I
    Mayo, Sheridan C.
    Thompson, Darren
    Fox, Jane
    Kumar, Beena
    Prodanovic, Zdenka
    Hausermann, Daniel
    Maksimenko, Anton
    Hall, Christopher
    Dimmock, Matthew
    Pavlov, Konstantin M.
    Lockie, Darren
    Rickard, Mary
    Gadomkar, Ziba
    Aminzadeh, Alaleh
    Vafa, Elham
    Peele, Andrew
    Quiney, Harry M.
    Lewis, Sarah
    Gureyev, Timur E.
    Brennan, Patrick C.
    Taba, Seyedamir Tavakoli
    JOURNAL OF MEDICAL IMAGING, 2021, 8 (05)
  • [2] Propagation-based Phase-Contrast X-ray Imaging at a Compact Light Source
    Gradl, Regine
    Dierolf, Martin
    Hehn, Lorenz
    Guenther, Benedikt
    Yildirim, Ali Oender
    Gleich, Bernhard
    Achterhold, Klaus
    Pfeiffer, Franz
    Morgan, Kaye Susannah
    SCIENTIFIC REPORTS, 2017, 7
  • [3] Material Decomposition Using Spectral Propagation-Based Phase-Contrast X-Ray Imaging
    Schaff, Florian
    Morgan, Kaye S.
    Pollock, James A.
    Croton, Linda C. P.
    Hooper, Stuart B.
    Kitchen, Marcus J.
    IEEE TRANSACTIONS ON MEDICAL IMAGING, 2020, 39 (12) : 3891 - 3899
  • [4] Evaluation of the Weighted Mean X-ray Energy for an Imaging System Via Propagation-Based Phase-Contrast Imaging
    Seifert, Maria
    Weule, Mareike
    Cipiccia, Silvia
    Flenner, Silja
    Hagemann, Johannes
    Ludwig, Veronika
    Michel, Thilo
    Neumayer, Paul
    Schuster, Max
    Wolf, Andreas
    Anton, Gisela
    Funk, Stefan
    Akstaller, Bernhard
    JOURNAL OF IMAGING, 2020, 6 (07)
  • [5] Propagation-based x-ray phase-contrast tomography of mastectomy samples using synchrotron radiation
    Gureyev, T. E.
    Nesterets, Ya. I.
    Baran, P. M.
    Taba, S. T.
    Mayo, S. C.
    Thompson, D.
    Arhatari, B.
    Mihocic, A.
    Abbey, B.
    Lockie, D.
    Fox, J.
    Kumar, B.
    Prodanovic, Z.
    Hausermann, D.
    Maksimenko, A.
    Hall, C.
    Peele, A. G.
    Dimmock, M.
    Pavlov, K. M.
    Cholewa, M.
    Lewis, S.
    Tromba, G.
    Quiney, H. M.
    Brennan, P. C.
    MEDICAL PHYSICS, 2019, 46 (12) : 5478 - 5487
  • [6] Phase-contrast X-ray imaging of breast
    Keyrilainen, Jani
    Bravin, Alberto
    Fernandez, Manuel
    Tenhunen, Mikko
    Virkkunen, Pekka
    Suortti, Pekka
    ACTA RADIOLOGICA, 2010, 51 (08) : 866 - 884
  • [7] Noise texture and signal detectability in propagation-based x-ray phase-contrast tomography
    Chou, Cheng-Ying
    Anastasio, Mark A.
    MEDICAL PHYSICS, 2010, 37 (01) : 270 - 281
  • [8] Feasibility study of propagation-based phase-contrast X-ray lung imaging on the Imaging and Medical beamline at the Australian Synchrotron
    Murrie, Rhiannon P.
    Stevenson, Andrew W.
    Morgan, Kaye S.
    Fouras, Andreas
    Paganin, David M.
    Siu, Karen K. W.
    JOURNAL OF SYNCHROTRON RADIATION, 2014, 21 : 430 - 445
  • [9] Optimisation of a propagation-based x-ray phase-contrast micro-CT system
    Nesterets, Yakov, I
    Gureyev, Timur E.
    Dimmock, Matthew R.
    JOURNAL OF PHYSICS D-APPLIED PHYSICS, 2018, 51 (11)
  • [10] Experimental optimization of X-ray propagation-based phase contrast imaging geometry
    Dierks, Hanna