Evaluation of full thread screw and different fixation configurations in Pauwels type III femoral neck fracture

被引:0
|
作者
Qiu, Jianjun [1 ]
Zou, Hanlin [1 ]
Zhang, Lei [1 ,2 ]
Zhou, Xu [1 ]
机构
[1] Shanghai Univ Tradit Chinese Med, Putuo Hosp, Dept Neurol, Shanghai 200062, Peoples R China
[2] Shanghai Univ Tradit Chinese Med, Putuo Hosp, 164 Lanxi Rd, Shanghai 200062, Peoples R China
关键词
Full thread screw; Different fixation configurations; Femoral neck fracture; Model rigidity; Axial displacement; Limit loads; CANNULATED CANCELLOUS SCREWS; SLIDING HIP SCREW; ADULTS; WEITBRECHT; RETINACULA; SYSTEM; PLATE;
D O I
10.1016/j.heliyon.2023.e21857
中图分类号
O [数理科学和化学]; P [天文学、地球科学]; Q [生物科学]; N [自然科学总论];
学科分类号
07 ; 0710 ; 09 ;
摘要
Objectives: The purpose of this study is to evaluate the value of full thread screw and different fixation configurations in Pauwels type III femoral neck fracture.Methods: A total of 40 artificial femoral model specimens were chosen, and Pauwels type III femoral neck fracture was simulated upon osteotomy at 80. According to random number table, models were divided into four groups (10 cases in each group): Group A received the paralleled fixation with three partial thread screws (PTSs), group B received the crossed fixation with three PTSs, group C received the paralleled fixation with two full thread screws (FTSs) and one PTS, and group D received the crossed fixation with two FTSs and one PTS. Changes including the model rigidity, axial displacement in fatigue test and limit loads for Pauwels type III femoral neck fracture models were analyzed through MTS 858 Mini Bionix II test system.Results: Among four groups, the model rigidity, axial displacement in fatigue test and limit loads were the highest in group D, and they were the lowest in group A. However, the model rigidity, axial displacement in fatigue test and limit loads between group B and group C showed no sta-tistically significant difference (P>0.05). Eventually, all the specimens were displaced along the fracture lines while the femoral head was split at varying degrees. After splits, the removal rate of fixation screws in group A (60.0 %) and group C (40.0 %) was significantly higher than that of group B (10.0 %) and group D (0 %) (P<0.05), but it showed no statistically significant difference between group A and group C, and between group B and group D (P>0.05).Conclusions: The crossed fixation configuration with two FTSs and one PTS in group D is proven to be more effective, which can go against the shear stress, tension and introversion in Pauwels type III femoral neck fracture models.
引用
收藏
页数:8
相关论文
共 50 条
  • [31] Femoral neck system (FNS) versus 4 cannulated compression screws (CCSs) in the treatment of young patients with Pauwels type III femoral neck fracture: a retrospective comparative study
    Gao, Yang
    Ma, Tianle
    Chang, Xiaohu
    Jia, Peng
    Li, Xiaoteng
    Tang, Xin
    JOURNAL OF ORTHOPAEDIC SURGERY AND RESEARCH, 2025, 20 (01):
  • [32] Biomechanical analysis of two medial buttress plate fixation methods to treat Pauwels type III femoral neck fractures
    Jichao Liu
    Zhengwei Li
    Jie Ding
    Bingzhe Huang
    Chengdong Piao
    BMC Musculoskeletal Disorders, 23
  • [33] Biomechanical analysis of two medial buttress plate fixation methods to treat Pauwels type III femoral neck fractures
    Liu, Jichao
    Li, Zhengwei
    Ding, Jie
    Huang, Bingzhe
    Piao, Chengdong
    BMC MUSCULOSKELETAL DISORDERS, 2022, 23 (01)
  • [34] Evaluating three internal fixation techniques for Pauwels III femoral neck fractures via finite element analysis
    Li, Ning
    Cheng, Kai-Yuan
    Fan, Jixing
    Li, Yu
    Yang, Minghui
    Zhu, Shiwen
    Jiang, Xieyuan
    SCIENTIFIC REPORTS, 2024, 14 (01):
  • [35] Sliding hip screw versus cannulated cancellous screws for fixation of femoral neck fracture in adults: A systematic review
    Ma, Jian-xiong
    Kuang, Ming-jie
    Xing, Fei
    Zhao, Yun-long
    Chen, Heng-ting
    Zhang, Lu-kai
    Fan, Zheng-rui
    Han, Chao
    Ma, Xin-long
    INTERNATIONAL JOURNAL OF SURGERY, 2018, 52 : 89 - 97
  • [36] Internal fixation system with the pyramid screw head for the treatment of Pauwels type III femoral neck fractures四棱锥型钉头内固定系统用于治疗Pauwels III型股骨颈骨折
    Songyuan Wang
    Xuan Deng
    Hao Zhong
    Lei Ma
    Xiyu Wang
    Xinqi Lou
    Xuanze Fan
    Wangping Duan
    Kai Zhang
    Pengcui Li
    Xiaochun Wei
    Yongwang Zhao
    Yanqin Wang
    Xiaogang Wu
    Yanru Xue
    Weiyi Chen
    Acta Mechanica Sinica, 2023, 39
  • [37] Analysis on risk factors for neck shortening after internal fixation for Pauwels II femoral neck fracture in young patients
    Fulong Zhao
    Lijuan Guo
    Xuefei Wang
    Yakui Zhang
    European Journal of Medical Research, 26
  • [38] Ideal length of thread forms for screws used in screw fixation of nondisplaced femoral neck fractures
    Liu, Christina
    Von Keudell, Arvind
    McTague, Michael
    Rodriguez, Edward K.
    Weaver, Michael J.
    INJURY-INTERNATIONAL JOURNAL OF THE CARE OF THE INJURED, 2019, 50 (03): : 727 - 732
  • [39] Analysis on risk factors for neck shortening after internal fixation for Pauwels II femoral neck fracture in young patients
    Zhao, Fulong
    Guo, Lijuan
    Wang, Xuefei
    Zhang, Yakui
    EUROPEAN JOURNAL OF MEDICAL RESEARCH, 2021, 26 (01)
  • [40] Minimally invasive screw fixation of the intracapsular femoral neck fracture in elderly patients
    Bosch, U
    Schreiber, T
    Skutek, M
    Cserháti, P
    Fekete, K
    Krettek, C
    CHIRURG, 2001, 72 (11): : 1292 - 1297