Reproducibility of radiomics features in partial volume correction of PET images

被引:0
|
作者
Azimi, Mohammad-Saber [1 ]
Kamali-Asl, Alireza [2 ]
Ay, Mohammad-Reza [3 ]
Hosseini, Mahboube Sadat [1 ]
Khorshidi, Fatemeh [4 ]
Arabi, Hossein [5 ]
Rahmim, Arman [6 ]
Zaidi, Habib [5 ]
机构
[1] Shahid Beheshti Univ, Dept Med Radiat Engn, Tajrish, Iran
[2] Shahid Beheshti Univ, Med Radiat Dept, Tajrish, Iran
[3] Univ Tehran Med Sci, Tehran, Iran
[4] Shahid Beheshti Univ, Tajrish, Iran
[5] Univ Geneva Hosp, Geneva, Switzerland
[6] Univ British Columbia, Vancouver, BC, Canada
关键词
D O I
暂无
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
P994
引用
收藏
页数:3
相关论文
共 50 条
  • [1] A recovery coefficient method for partial volume correction of PET images
    Shyam M. Srinivas
    Thiruvenkatasamy Dhurairaj
    Sandip Basu
    Gonca Bural
    Suleman Surti
    Abass Alavi
    Annals of Nuclear Medicine, 2009, 23 : 341 - 348
  • [2] A recovery coefficient method for partial volume correction of PET images
    Srinivas, Shyam M.
    Dhurairaj, Thiruvenkatasamy
    Basu, Sandip
    Bural, Gonca
    Surti, Suleman
    Alavi, Abass
    ANNALS OF NUCLEAR MEDICINE, 2009, 23 (04) : 341 - 348
  • [3] A simple method for partial volume effect correction in PET images
    Department of Nuclear Medicine, General Hospital of PLA, Beijing 100853, China
    不详
    Hedianzixue Yu Tance Jishue, 2007, 6 (1231-1238): : 1231 - 1238
  • [4] Correction for partial volume effect in PET blood flow images
    Gage, HD
    Fahey, FH
    Santago, P
    Harkness, BA
    Keyes, JW
    MEDICAL IMAGING 1996: PHYSIOLOGY AND FUNCTION FROM MULTIDIMENSIONAL IMAGES, 1996, 2709 : 244 - 253
  • [5] Subtle MR Guidance for Partial Volume Correction of PET Images: A Comparison of Techniques
    Zhu, Yansong
    Gao, Yuanyuan
    Rahmim, Arman
    2019 IEEE NUCLEAR SCIENCE SYMPOSIUM AND MEDICAL IMAGING CONFERENCE (NSS/MIC), 2019,
  • [6] Partial volume correction of whole body PET images using the wavelet transform
    Spinelli, Antonello E.
    Guerrieri, Luca
    D'Ambrosio, Daniela
    Franchi, Roberto
    Boschi, Stefano
    Marengo, Mario
    OPTICAL AND DIGITAL IMAGE PROCESSING, 2008, 7000
  • [7] Partial Volume Correction Strategies in PET
    Rousset, Olivier
    Rahmim, Arman
    Alavi, Abass
    Zaidi, Habib
    PET CLINICS, 2007, 2 (02) : 235 - 249
  • [8] Partial Volume Correction in PET Images: A Single Correction Method Applied for Multiple Source to Background Ratios
    Piper, J.
    Shen, G.
    Nelson, A. D.
    Nelson, A. S.
    MEDICAL PHYSICS, 2009, 36 (06)
  • [9] Automatic Partial Volume Correction in Cardiac PET without Anatomical Images: A Preliminary Study
    Panetta, D.
    Pisani, P.
    Sorace, O.
    Salvadori, P. A.
    EUROPEAN JOURNAL OF NUCLEAR MEDICINE AND MOLECULAR IMAGING, 2009, 36 : S269 - S269
  • [10] Correction of partial volume effect of cerebral glucose metabolism images measured by PET/MRI
    Ito, Hiroshi
    Nambu, Takeyuki
    Matsubara, Keisuke
    Kubo, Hitoshi
    Oriuchi, Noboru
    Ishii, Shirou
    JOURNAL OF NUCLEAR MEDICINE, 2018, 59