Experimental analysis of pulsatile flow effects on flow structure in transitional-type cavity

被引:0
|
作者
Sereika, Justas [1 ]
Vilkinis, Paulius [1 ]
Skarbalius, Gediminas [1 ]
Dziugys, Algis [1 ]
Pedisius, Nerijus [1 ]
机构
[1] Lithuanian Energy Inst, Lab Heat Equipment Res & Testing, Breslaujos Str 3, LT-44403 Kaunas, Lithuania
关键词
Pulsatile flow; Flow separation; Transitional-type cavity; Turbulence intensity; Flow stability; BACKWARD-FACING STEP; HEAT-TRANSFER ENHANCEMENT; NUMERICAL-ANALYSIS; MIXED CONVECTION; GROOVED CHANNEL; NANOFLUID FLOW; INLET;
D O I
10.1016/j.expthermflusci.2023.111073
中图分类号
O414.1 [热力学];
学科分类号
摘要
Studies combining flow separation and pulsatile flow phenomena are inherent in the field of biomedicine and have many engineering and biomedical applications. In this study, the pulsatile flow structure is investigated experimentally based on a transitional-type cavity with a length-to-depth ratio of 8 using a microparticle image velocimetry system. A pulsatile flow is generated by pulsating the inlet pressure in sinusoidal pulses using a pressure control unit. Stationary flow and four sets of pulsatile parameters are investigated: two pulsation am-plitudes (A = 0.15 and 0.60) and two pulsation frequencies (f = 0.5 and 1 Hz) in the Reynolds range of 50-2000. The recirculation flow dynamics in a cavity are analyzed by investigating the effect of pulsations on the flow structure and statistical flow parameters such as vorticity, shear rate, and turbulence intensity. The analysis shows that the effect of the pulsation amplitude on the recirculation zone dynamics is more prominent than that of the pulsation frequency. The magnitude of the recirculation zone reduction achieved by the pulsatile flow is inversely proportional to the pulsation amplitude. A reduction in the recirculation zone length decreases the shear rate distribution along the cavity. Additionally, an analysis into the turbulence intensity shows that effect of pulsations is negligible when the flow approaches the turbulent flow regime.
引用
收藏
页数:10
相关论文
共 50 条
  • [21] Direct numerical simulations of transitional pulsatile flow through a constriction
    Beratlis, N.
    Balaras, E.
    Kiger, K.
    JOURNAL OF FLUID MECHANICS, 2007, 587 : 425 - 451
  • [22] Experimental and numerical analysis of heat transfer enhancement and flow characteristics in grooved channel for pulsatile flow
    Zhang, Fengge
    Bian, Yongning
    Liu, Yang
    Pan, Junxiu
    Yang, Yunjie
    Arima, Hirofumi
    INTERNATIONAL JOURNAL OF HEAT AND MASS TRANSFER, 2019, 141 : 1168 - 1180
  • [23] Numerical and experimental analysis of the transitional flow across a real stenosis
    R. Agujetas
    C. Ferrera
    A. C. Marcos
    J. P. Alejo
    J. M. Montanero
    Biomechanics and Modeling in Mechanobiology, 2017, 16 : 1447 - 1458
  • [24] Numerical and experimental analysis of the transitional flow across a real stenosis
    Agujetas, R.
    Ferrera, C.
    Marcos, A. C.
    Alejo, J. P.
    Montanero, J. M.
    BIOMECHANICS AND MODELING IN MECHANOBIOLOGY, 2017, 16 (04) : 1447 - 1458
  • [25] Present state of art on pulsatile flow theory -: (Part 1:: Laminar and transitional flow regimes)
    Gündogdu, MY
    Çarpinlioglu, MÖ
    JSME INTERNATIONAL JOURNAL SERIES B-FLUIDS AND THERMAL ENGINEERING, 1999, 42 (03) : 384 - 397
  • [26] An experimental study on turbulent-stripe structure in transitional channel flow
    Hashimoto, S.
    Hasobe, A.
    Tsukahara, T.
    Kawaguchi, Y.
    Kawamura, H.
    TURBULENCE, HEAT AND MASS TRANSFER 6, 2009, : 193 - 196
  • [27] Influence of membrane oxygenators on the pulsatile flow in extracorporeal circuits:: an experimental analysis
    Ündar, A
    Fraser, CD
    INTERNATIONAL JOURNAL OF ARTIFICIAL ORGANS, 1998, 21 (03): : 179 - 180
  • [28] Influence of membrane oxygenators on the pulsatile flow in extracorporeal circuits: an experimental analysis
    Undar, A
    Fraser, CD
    INTERNATIONAL JOURNAL OF ARTIFICIAL ORGANS, 1998, 21 (11): : 714 - 715
  • [29] Evolution of vortex structures in an open deep cavity under pulsatile flow conditions: An experimental study
    Zhang, Yan
    Eichholz, Benjamin
    Zhang, Ruihang
    PHYSICS OF FLUIDS, 2022, 34 (09)
  • [30] Influence of membrane oxygenators on the pulsatile flow in extracorporeal circuits: an experimental analysis
    Inzoli, F
    Pennati, G
    Mastrantonio, F
    Fini, M
    INTERNATIONAL JOURNAL OF ARTIFICIAL ORGANS, 1997, 20 (08): : 455 - 462