Mechanical Power Density Predicts Prolonged Ventilation Following Double Lung Transplantation

被引:2
作者
Ghiani, Alessandro [1 ]
Kneidinger, Nikolaus [2 ,3 ]
Neurohr, Claus [1 ,3 ]
Frank, Sandra [4 ]
Hinske, Ludwig Christian [4 ,5 ]
Schneider, Christian [3 ,6 ]
Michel, Sebastian [3 ,7 ]
Irlbeck, Michael [4 ]
机构
[1] Robert Bosch Hosp GmbH, Lung Ctr Stuttgart, Dept Pulmonol & Resp Med, Schillerhoehe Lung Clin GmbH, Stuttgart, Germany
[2] Ludwig Maximilians Univ Munchen, LMU Univ Hosp, Dept Med 5, Munich, Germany
[3] German Ctr Lung Res DZL, Comprehens Pneumol Ctr CPC M, Munich, Germany
[4] Ludwig Maximilians Univ LMU Munich, Dept Anesthesiol, Munich, Germany
[5] Univ Hosp Augsburg, Inst Digital Med, Augsburg, Germany
[6] Ludwig Maximilians Univ Munich LMU, Dept Thorac Surg, Munich, Germany
[7] Ludwig Maximilians Univ LMU Munich, Clin Cardiac Surg, Munich, Germany
关键词
lung transplantation; prolonged ventilation; ventilator weaning; extubation; mechanical power; PRIMARY GRAFT DYSFUNCTION; RESPIRATORY-FAILURE; TIDAL VOLUMES; SIZE MISMATCH; INJURY; MULTICENTER; PARAMETERS; MANAGEMENT; PRESSURE; SUPPORT;
D O I
10.3389/ti.2023.11506
中图分类号
R61 [外科手术学];
学科分类号
摘要
Prolonged mechanical ventilation (PMV) after lung transplantation poses several risks, including higher tracheostomy rates and increased in-hospital mortality. Mechanical power (MP) of artificial ventilation unifies the ventilatory variables that determine gas exchange and may be related to allograft function following transplant, affecting ventilator weaning. We retrospectively analyzed consecutive double lung transplant recipients at a national transplant center, ventilated through endotracheal tubes upon ICU admission, excluding those receiving extracorporeal support. MP and derived indexes assessed up to 36 h after transplant were correlated with invasive ventilation duration using Spearman's coefficient, and we conducted receiver operating characteristic (ROC) curve analysis to evaluate the accuracy in predicting PMV (>72 h), expressed as area under the ROC curve (AUROC). PMV occurred in 82 (35%) out of 237 cases. MP was significantly correlated with invasive ventilation duration (Spearman's rho = 0.252 [95% CI 0.129-0.369], p < 0.01), with power density (MP normalized to lung-thorax compliance) demonstrating the strongest correlation (rho = 0.452 [0.345-0.548], p < 0.01) and enhancing PMV prediction (AUROC 0.78 [95% CI 0.72-0.83], p < 0.01) compared to MP (AUROC 0.66 [0.60-0.72], p < 0.01). Mechanical power density may help identify patients at risk for PMV after double lung transplantation.
引用
收藏
页数:12
相关论文
共 50 条
[31]   Donor ventilation parameters as predictors for length of mechanical ventilation after lung transplantation: Results of a prospective multicenter study [J].
Benazzo, Alberto ;
Schwarz, Stefan ;
Frommlet, Florian ;
Sinn, Katharina ;
Schweiger, Thomas ;
Klikovits, Thomas ;
Hoda, Alireza Mir ;
Moser, Bernhard ;
Matilla, Jose Ramon ;
Vamos, Ferenc Renyi ;
Lang, Gyoergy ;
Jaksch, Peter ;
Di Nardo, Matteo ;
Del Sorbo, Lorenzo ;
Taghavi, Shahrokh ;
Keshavjee, Shaf ;
Klepetko, Walter ;
Cypel, Marcelo ;
Hoetzenecker, Konrad .
JOURNAL OF HEART AND LUNG TRANSPLANTATION, 2021, 40 (01) :33-41
[32]   Estimating risk of prolonged mechanical ventilation after liver transplantation in children: PROVE-ALT score [J].
Mian, Muhammad Umair M. ;
Kennedy, Curtis E. ;
Coss-Bu, Jorge A. ;
Javaid, Ramsha ;
Naeem, Buria ;
Lam, Fong Wilson ;
Fogarty III, Thomas ;
Arikan, Ayse A. ;
Nguyen, Trung C. ;
Bashir, Dalia ;
Virk, Manpreet ;
Harpavat, Sanjiv ;
Galvan, Nhu Thao Nguyen ;
Rana, Abbas A. ;
Goss, John A. ;
Leung, Daniel H. ;
Desai, Moreshwar S. .
PEDIATRIC TRANSPLANTATION, 2024, 28 (01)
[33]   Extravascular Lung Water and Pulmonary Vascular Permeability Index Measured at the End of Surgery Are Independent Predictors of Prolonged Mechanical Ventilation in Patients Undergoing Liver Transplantation [J].
Garutti, Ignacio ;
Sanz, Javier ;
Olmedilla, Luis ;
Tranche, Itziar ;
Vilchez, Almudena ;
Fernandez-Quero, Lorenzo ;
Banares, Rafael ;
Maria Perez-Pena, Jose .
ANESTHESIA AND ANALGESIA, 2015, 121 (03) :736-745
[34]   Stereotactic ablative radiotherapy for early-stage lung cancer following double lung transplantation [J].
Hanbo Chen ;
Jussi Tikkanen ;
R. Gabriel Boldt ;
Alexander V. Louie .
Radiation Oncology, 13
[35]   Stereotactic ablative radiotherapy for early-stage lung cancer following double lung transplantation [J].
Chen, Hanbo ;
Tikkanen, Jussi ;
Boldt, R. Gabriel ;
Louie, Alexander, V .
RADIATION ONCOLOGY, 2018, 13
[36]   Mechanical power normalized to aerated lung predicts noninvasive ventilation failure and death and contributes to the benefits of proning in COVID-19 hypoxemic respiratory failure [J].
Musso, Giovanni ;
Taliano, Claudio ;
De Iuliis, Marco ;
Paschetta, Elena ;
Fonti, Caterina ;
Ferraris, Andrea ;
Druetta, Marta ;
Vianou, Ines Sarah ;
Ranghino, Francesca ;
Riedo, Federica ;
Deangelis, Davide ;
Tirabassi, Gloria .
EPMA JOURNAL, 2023, 14 (03) :341-379
[37]   Mechanical power normalized to aerated lung predicts noninvasive ventilation failure and death and contributes to the benefits of proning in COVID-19 hypoxemic respiratory failure [J].
Giovanni Musso ;
Claudio Taliano ;
Marco De Iuliis ;
Elena Paschetta ;
Caterina Fonti ;
Andrea Ferraris ;
Marta Druetta ;
Ines Sarah Vianou ;
Francesca Ranghino ;
Federica Riedo ;
Davide Deangelis ;
Gloria Tirabassi .
EPMA Journal, 2023, 14 :341-379
[38]   Scintigraphic diagnosis of silent aspiration following double-sided lung transplantation [J].
Tonshoff, G ;
Stock, U ;
Bohuslavizki, KH ;
Brenner, W ;
CostardJaekle, A ;
Cremer, J ;
Clausen, M .
NUKLEARMEDIZIN, 1996, 35 (04) :140-142
[39]   Costs and outcomes of prolonged cytomegalovirus prophylaxis to cover the enhanced immunosuppression phase following lung transplantation [J].
Gerbase, MW ;
Dubois, D ;
Rothmeier, C ;
Spiliopoulos, A ;
Wunderli, W ;
Nicod, LP .
CHEST, 1999, 116 (05) :1265-1272
[40]   End-Expiratory Lung Volumes During Spontaneous Breathing Trials in Tracheostomized Subjects on Prolonged Mechanical Ventilation [J].
Cheng, Jui-Chen ;
Chen, Hui-Chuan ;
Jerng, Jih-Shuin ;
Kuo, Ping-Hung ;
Wu, Huey-Dong .
RESPIRATORY CARE, 2021, 66 (11) :1704-1712