Refining Boron Isotopic Measurements of Silicate Samples by Multi-Collector-Inductively Coupled Plasma-Mass Spectrometry (MC-ICP-MS)

被引:2
|
作者
Paul, Andre N. [1 ,2 ,3 ]
Stewart, Joseph A. [2 ]
Agostini, Samuele [4 ]
Kirstein, Linda A. [1 ]
De Hoog, Jan C. M. [1 ]
Savov, Ivan P. [5 ]
Walowski, Kristina [1 ,6 ]
Rae, James W. B. [7 ]
Elliott, Tim [2 ]
机构
[1] Univ Edinburgh, Sch Geosci, Edinburgh EH9 3FE, Scotland
[2] Univ Bristol, Sch Earth Sci, Bristol, England
[3] Univ Geneva, Dept Earth Sci, Geneva, Switzerland
[4] Consiglio Nazl Ric CNR, Ist Geosci & Georisorse, Pisa, Italy
[5] Univ Leeds, Sch Earth & Environm, Leeds, England
[6] Western Washington Univ, Dept Geol, Bellingham, WA USA
[7] Univ St Andrews, Sch Earth & Environm Sci, St Andrews, Scotland
关键词
delta B-11(SRM 951); MORB volcanic glass; OIB volcanic glass; silicate reference materials; MC-ICP-MS; HF digestion; boron isotopes; EAST PACIFIC RISE; ROCK SAMPLES; GEOLOGICAL-MATERIALS; IN-SITU; EVAPORATION; EXCHANGE; PRECISE; RIDGE; MICROSUBLIMATION; PURIFICATION;
D O I
10.1111/ggr.12527
中图分类号
P3 [地球物理学]; P59 [地球化学];
学科分类号
0708 ; 070902 ;
摘要
Solution MC-ICP-MS is an established technique for high precision boron isotope measurement results (delta B-11(SRM 951)) in carbonates, yet its application to silicate rocks has been limited. Impediments include volatilisation during silicate dissolution and contamination during chemical purification. To address this, we present a low-blank sample preparation procedure that couples hydrofluoric acid-digestion and low-temperature evaporation (mannitol-free), to an established MC-ICP-MS measurement procedure following chemical purification using B-specific Amberlite IRA 743 resin. We obtain accurate delta B-11(SRM 951) values (intermediate precision +/- 0.2 parts per thousand) for boric acid (BAM ERM-AE121 19.65 +/- 0.14 parts per thousand) and carbonate (NIST RM 8301 (Coral) 24.24 +/- 0.11 parts per thousand) reference materials. For silicate reference materials covering mafic to felsic compositions we obtain delta B-11(SRM 951) with intermediate precision < +/- 0.6 parts per thousand (2s), namely JB-2 6.9 +/- 0.4 parts per thousand; IAEA-B-5 -6.0 +/- 0.6 parts per thousand; IAEA-B-6 -3.9 +/- 0.5 parts per thousand (2s). Furthermore, splits of these same reference materials were processed by an alternative fusion and purification procedure. We find excellent agreement between delta B-11(SRM 951) measurement results by MC-ICP-MS of the reference materials using both sample processing techniques. These measurement results show that our sample processing and MC-ICP-MS methods provide consistent delta B-11(SRM 951) values for low B-mass fraction samples. We present new data from Mid Ocean Ridge Basalt (MORB) glass, documenting a range in delta B-11(SRM 951) from -5.6 +/- 0.3 parts per thousand to -8.8 +/- 0.5 parts per thousand (2s), implying some upper mantle delta B-11(SRM 951) heterogeneity.
引用
收藏
页码:91 / 108
页数:18
相关论文
共 50 条
  • [1] Precise measurement of Fe isotopes in marine samples by multi-collector inductively coupled plasma mass spectrometry (MC-ICP-MS)
    de Jong, Jeroen
    Schoemann, Veronique
    Tison, Jean-Louis
    Becquevort, Sylvie
    Masson, Florence
    Lannuzel, Delphine
    Petit, Jerome
    Chou, Lei
    Weis, Dominique
    Mattielli, Nadine
    ANALYTICA CHIMICA ACTA, 2007, 589 (01) : 105 - 119
  • [2] Lead isotope measurement using a multi-collector inductively coupled plasma mass spectrometry (MC-ICP-MS)
    Choi, Hye-Bin
    Ryu, Jong-Sik
    Park, Sanghee
    Lee, Jeonghoon
    JOURNAL OF THE GEOLOGICAL SOCIETY OF KOREA, 2018, 54 (03) : 311 - 318
  • [3] Simplified technique for the measurements of Re-Os isotope by multicollector inductively coupled plasma mass spectrometry (MC-ICP-MS)
    Li, Jie
    Liang, Xi-rong
    Xu, Ji-feng
    Suzuki, Katsuhiko
    Dong, Yan-hui
    GEOCHEMICAL JOURNAL, 2010, 44 (01) : 73 - 80
  • [4] Precise measurement of uranium isotope ratios in Fukushima soils using multi-collector inductively coupled plasma mass spectrometry (MC-ICP-MS)
    Murugan, Rajamanickam
    Veerasamy, Nimelan
    Zhao, Ye
    Aono, Tatsuo
    Sahoo, Sarata Kumar
    INTERNATIONAL JOURNAL OF MASS SPECTROMETRY, 2021, 467
  • [5] Validation of the determination of the B isotopic composition in Roman glasses with laser ablation multi-collector inductively coupled plasma-mass spectrometry
    Devulder, Veerle
    Gerdes, Axel
    Vanhaecke, Frank
    Degryse, Patrick
    SPECTROCHIMICA ACTA PART B-ATOMIC SPECTROSCOPY, 2015, 105 : 116 - 120
  • [6] The influence of the double spike proportion effect on stable isotope (Zn, Mo, Cd, and Sn) measurements by multicollector-inductively coupled plasma-mass spectrometry (MC-ICP-MS)
    Zhang, Le
    Li, Jie
    Xu, Yi-Gang
    Ren, Zhong-Yuan
    JOURNAL OF ANALYTICAL ATOMIC SPECTROMETRY, 2018, 33 (04) : 555 - 562
  • [7] Measurement of silicon stable isotope natural abundances via multicollector inductively coupled plasma mass spectrometry (MC-ICP-MS)
    De la Rocha, CL
    GEOCHEMISTRY GEOPHYSICS GEOSYSTEMS, 2002, 3
  • [8] Separation and Isotopic Measurement of Mg Isotope Ratios in Tooth Samples Using Multiple Collector-Inductively Coupled Plasma-Mass Spectrometry
    Li Zi-Xia
    He Mao-Yong
    Lu Hai
    Ren Tong-Xiang
    CHINESE JOURNAL OF ANALYTICAL CHEMISTRY, 2016, 44 (05) : 787 - 791
  • [9] Direct determination of the 237Np/238U ratio in nuclear fuel samples by multicollection inductively coupled plasma mass spectrometry (MC-ICP-MS)
    Mialle, S.
    Nonell, A.
    Cruchet, C.
    Caussignac, C.
    Marie, M.
    Rincel, A.
    Isnard, H.
    JOURNAL OF RADIOANALYTICAL AND NUCLEAR CHEMISTRY, 2024, 333 (10) : 4825 - 4835
  • [10] MC-ICP-MS Isotope Measurements with Direct Injection Nebulisation (d-DIHEN): Optimisation and Application to Boron in Seawater and Carbonate Samples
    Louvat, Pascale
    Bouchez, Julien
    Paris, Guillaume
    GEOSTANDARDS AND GEOANALYTICAL RESEARCH, 2011, 35 (01) : 75 - 88