High time-resolution MRPC detector for TOF-PET

被引:2
|
作者
Liu, J. [1 ]
Wang, Y. [1 ]
Guo, B. [1 ]
Yu, Y. [1 ]
Han, D. [1 ]
Li, Y. [1 ]
机构
[1] Tsinghua Univ, Dept Engn Phys, Key Lab Particle & Radiat Imaging, Beijing 100084, Peoples R China
关键词
MRPC detector; TOF-PET; Time resolution; Detection efficiency;
D O I
10.1016/j.nima.2023.168453
中图分类号
TH7 [仪器、仪表];
学科分类号
0804 ; 080401 ; 081102 ;
摘要
The traditional TOF-PET (Positron emission tomography) mainly uses the structure of a scintillator detector connected to a photomultiplier tube. The structure has the disadvantages that time resolution is not good enough (about 300 ps FWHM) for improving the signal-to-noise ratio of the acquisition system, which is not conducive to the detection of microtumors in the clinic and reduction in imaging time. The thickness of the scintillator is large (greater than 3 cm). Traditional PET has low geometric efficiency and sensitivity. It requires a long time to complete a full-body scan. However, the MRPC can be made into a 2.4-meter-long whole body PET. The high cost of traditional TOF-PET limits its widespread use in medical and other fields. The excellent time resolution of MRPC makes MRPC TOF-PET a good application prospect. This paper shows the time resolution of two 32-gap MRPCs with 128 & mu;m gap thickness on cosmic rays and 0.511 MeV photons. By using the fast front-end amplifier and waveform acquisition system, the time resolution for cosmic rays is 27 ps and the rms time accuracy per 0.511 MeV photon is 72 ps. The time resolution in terms of FWHM of the time difference between photon pairs is 239 ps FWHM. The reason why MRPC detectors have different time resolutions for cosmic rays and 0.511 MeV photons is related to the different ways different particles act and the thickness of the detector. We propose to use a Cerenkov radiator to convert gamma into ultraviolet photons and use a composite photocathode to detect, improving the detection efficiency to 6.4% for RPC.
引用
收藏
页数:5
相关论文
共 50 条
  • [41] Clinical evaluation of PET image quality as a function of acquisition time in a new TOF-PET/MR compared to TOF-PET/CT - initial results
    Konstantinos Zeimpekis
    Martin Huellner
    Felipe De Galiza Barbosa
    Edwin Ter Voert
    Helen Davison
    Gaspar Delso
    Patrick Veit-Haibach
    EJNMMI Physics, 2 (Suppl 1)
  • [42] Scalable electronic readout design for a 100 ps coincidence time resolution TOF-PET system
    Pourashraf, Shirin
    Gonzalez-Montoro, Andrea
    Won, Jun Yeon
    Lee, Min Sun
    Cates, Joshua W.
    Zhao, Zhixiang
    Lee, Jae Sung
    Levin, Craig S.
    PHYSICS IN MEDICINE AND BIOLOGY, 2021, 66 (08):
  • [43] Study of TOF-PET Performance
    Takeshita, Tohru
    Yamazaki, Makoto
    Hasegawa, Yoji
    PROCEEDINGS OF THE 2ND INTERNATIONAL CONFERENCE ON TECHNOLOGY AND INSTRUMENTATION IN PARTICLE PHYSICS (TIPP 2011), 2012, 37 : 1461 - 1465
  • [44] A prototype of the high time resolution MRPC
    Li, C
    Wu, J
    Chen, HF
    Wang, XL
    Xu, ZZ
    Wang, ZM
    Shao, M
    Huang, SL
    Ruan, LJ
    HIGH ENERGY PHYSICS AND NUCLEAR PHYSICS-CHINESE EDITION, 2001, 25 (09): : 933 - 936
  • [45] Clinical Evaluation of PET Image Quality as a Function of Acquisition Time in a New TOF-PET/MRI Compared to TOF-PET/CT-Initial Results
    Zeimpekis, Konstantinos G.
    Barbosa, Felipe
    Huellner, Martin
    ter Voert, Edwin
    Davison, Helen
    Veit-Haibach, Patrick
    Delso, Gaspar
    MOLECULAR IMAGING AND BIOLOGY, 2015, 17 (05) : 735 - 744
  • [46] Fast Emitting Nanocomposites for High-Resolution ToF-PET Imaging Based on Multicomponent Scintillators
    Orfano, Matteo
    Pagano, Fiammetta
    Mattei, Ilaria
    Cova, Francesca
    Secchi, Valeria
    Bracco, Silvia
    Rogers, Edith
    Barbieri, Luca
    Lorenzi, Roberto
    Bizarri, Gregory
    Auffray, Etiennette
    Monguzzi, Angelo
    ADVANCED MATERIALS TECHNOLOGIES, 2024, 9 (10)
  • [47] Development of the MRPC for the TOF system of the MultiPurpose Detector
    Babkin, V. A.
    Bazylev, S. N.
    Burdenyuk, I. S.
    Buryakov, M. G.
    Dmitriev, A. V.
    Dulov, P. O.
    Golovatyuk, V. M.
    Lobastov, S. P.
    Rumyantsev, M. M.
    Schipunov, A. V.
    Shutov, A. V.
    Slepnev, I. V.
    Slepnev, V. M.
    Terletskiy, A. V.
    Volgin, S. V.
    JOURNAL OF INSTRUMENTATION, 2016, 11
  • [48] High Voltage Photodetector Calibration for Improved Timing Resolution with Scintillation Detectors for TOF-PET Imaging
    Davidson, Z. S.
    Wiener, R. I.
    Newcomer, F. M.
    VanBerg, R.
    Karp, J. S.
    2011 IEEE NUCLEAR SCIENCE SYMPOSIUM AND MEDICAL IMAGING CONFERENCE (NSS/MIC), 2011, : 2338 - 2341
  • [49] Prototype of the high time resolution MRPC
    Li, C.
    Wu, J.
    Chen, H.F.
    Wang, X.L.
    Xu, Z.Z.
    Wang, Z.M.
    Shao, M.
    Huang, S.L.
    Ruan, L.J.
    Kao Neng Wu Li Yu Ho Wu Li/High Energy Physics and Nuclear Physics, 2001, 25 (09):
  • [50] Pilot tests of a PET detector using the TOF-PET ASIC based on monolithic crystals and SiPMs
    Aguilar, A.
    Gonzalez-Montoro, A.
    Gonzalez, A. J.
    Hernandez, L.
    Monzo, J. M.
    Bugalho, R.
    Ferramacho, L.
    Benlloch, J. M.
    JOURNAL OF INSTRUMENTATION, 2016, 11