High time-resolution MRPC detector for TOF-PET

被引:2
|
作者
Liu, J. [1 ]
Wang, Y. [1 ]
Guo, B. [1 ]
Yu, Y. [1 ]
Han, D. [1 ]
Li, Y. [1 ]
机构
[1] Tsinghua Univ, Dept Engn Phys, Key Lab Particle & Radiat Imaging, Beijing 100084, Peoples R China
关键词
MRPC detector; TOF-PET; Time resolution; Detection efficiency;
D O I
10.1016/j.nima.2023.168453
中图分类号
TH7 [仪器、仪表];
学科分类号
0804 ; 080401 ; 081102 ;
摘要
The traditional TOF-PET (Positron emission tomography) mainly uses the structure of a scintillator detector connected to a photomultiplier tube. The structure has the disadvantages that time resolution is not good enough (about 300 ps FWHM) for improving the signal-to-noise ratio of the acquisition system, which is not conducive to the detection of microtumors in the clinic and reduction in imaging time. The thickness of the scintillator is large (greater than 3 cm). Traditional PET has low geometric efficiency and sensitivity. It requires a long time to complete a full-body scan. However, the MRPC can be made into a 2.4-meter-long whole body PET. The high cost of traditional TOF-PET limits its widespread use in medical and other fields. The excellent time resolution of MRPC makes MRPC TOF-PET a good application prospect. This paper shows the time resolution of two 32-gap MRPCs with 128 & mu;m gap thickness on cosmic rays and 0.511 MeV photons. By using the fast front-end amplifier and waveform acquisition system, the time resolution for cosmic rays is 27 ps and the rms time accuracy per 0.511 MeV photon is 72 ps. The time resolution in terms of FWHM of the time difference between photon pairs is 239 ps FWHM. The reason why MRPC detectors have different time resolutions for cosmic rays and 0.511 MeV photons is related to the different ways different particles act and the thickness of the detector. We propose to use a Cerenkov radiator to convert gamma into ultraviolet photons and use a composite photocathode to detect, improving the detection efficiency to 6.4% for RPC.
引用
收藏
页数:5
相关论文
共 50 条
  • [31] Comparative timing measurements of LYSO and LFS to achieve the best time resolution for TOF-PET
    Doroud, K.
    Rodriguez, A.
    Williams, M. C. S.
    Zichichi, A.
    Zuyeuski, R.
    2014 IEEE NUCLEAR SCIENCE SYMPOSIUM AND MEDICAL IMAGING CONFERENCE (NSS/MIC), 2014,
  • [32] Timing resolution improvement using DOI information in a four-layer scintillation detector for TOF-PET
    Shibuya, Kengo
    Nishikido, Fumihiko
    Tsuda, Tomoaki
    Kobayashi, Tetsuya
    Lam, Chihfung
    Yamaya, Taiga
    Yoshida, Eiji
    Inadama, Naoko
    Murayama, Hideo
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 2008, 593 (03): : 572 - 577
  • [33] Time rectification system for in-beam TOF-PET
    Chen, Jin-Da
    Xu, Hu-Shan
    Chen, Ruo-Fu
    Hu, Zheng-Guo
    Tang, Bin
    Wu, Da-Peng
    Yue, Ke
    Yu, Yu-Hong
    Zhang, Xue-Heng
    Kong, Jie
    Ye, Rui-Ping
    Wang, Jian-Song
    Zhang, Xue-Ying
    Guo, Zhong-Yan
    Yuanzineng Kexue Jishu/Atomic Energy Science and Technology, 2011, 45 (01): : 97 - 101
  • [34] Characterization of Scintillation Pulses in Time Determination in TOF-PET
    Guo, Ning
    Xie, Qingguo
    Zhu, Jun
    2009 16TH IEEE-NPSS REAL TIME CONFERENCE, 2009, : 304 - 307
  • [35] Determining timing resolution from TOF-PET emission data
    Vandenberghe, S.
    Matej, S.
    Daube-Witherspoon, M. E.
    Guerchaft, M.
    Verhaeghe, J.
    Bol, A.
    van Elmbt, L.
    Lemahieu, I.
    Karp, J. S.
    2007 IEEE NUCLEAR SCIENCE SYMPOSIUM CONFERENCE RECORD, VOLS 1-11, 2007, : 2727 - +
  • [36] Investigation of the time performance of a LYSO array for TOF-PET
    Liu Jun-Hui
    Cheng Jin-Xing
    Xu Jiong-Hui
    Cheng Feng-Feng
    Li Dao-Wu
    Zhang Zhi-Ming
    Wang Bao-Yi
    Wei Long
    CHINESE PHYSICS C, 2015, 39 (12)
  • [37] Investigation of the time performance of a LYSO array for TOF-PET
    刘军辉
    程金星
    徐炯辉
    成枫锋
    李道武
    章志明
    王宝义
    魏龙
    Chinese Physics C, 2015, 39 (12) : 107 - 112
  • [38] Analytical model of coincidence resolving time in TOF-PET
    Wieczorek, H.
    Thon, A.
    Dey, T.
    Khanin, V.
    Rodnyi, P.
    PHYSICS IN MEDICINE AND BIOLOGY, 2016, 61 (12): : 4699 - 4710
  • [39] Nanopattern multi-well avalanche selenium detector for TOF-PET
    LaBella, Andy
    Zhao, Wei
    Goldan, Amir H.
    PHYSICS IN MEDICINE AND BIOLOGY, 2021, 66 (13):
  • [40] Clinical Evaluation of PET Image Quality as a Function of Acquisition Time in a New TOF-PET/MRI Compared to TOF-PET/CT—Initial Results
    Konstantinos G. Zeimpekis
    Felipe Barbosa
    Martin Hüllner
    Edwin ter Voert
    Helen Davison
    Patrick Veit-Haibach
    Gaspar Delso
    Molecular Imaging and Biology, 2015, 17 : 735 - 744