Reliable Crack Monitoring Based on Guided Wave Through Periodically Loaded Transmission Line

被引:4
|
作者
Zhang, Jun [1 ]
Hu, Wenlong [1 ]
Chen, Zebin [1 ]
Yang, Pengchuan [1 ]
Wang, Kun [1 ]
Xie, Xiangyu [2 ]
Huang, Bei [3 ]
Dong, Lihong [4 ]
Wang, Haidou [4 ,5 ]
机构
[1] Guangdong Univ Technol, Sch Informat Engn, Guangzhou 510006, Peoples R China
[2] Guiyang Univ, Guizhou Prov Coll Based Engn Res Ctr Mat Prot Wea, Guiyang 550005, Peoples R China
[3] Guangdong Polytech Normal Univ, Sch Elect & Informat, Guangzhou 510665, Peoples R China
[4] Army Acad Armored Forces, Natl Key Lab Remfg, Beijing 100072, Peoples R China
[5] Army Acad Armored Forces, Natl Engn Res Ctr Remfg, Beijing 100072, Peoples R China
基金
中国国家自然科学基金;
关键词
Sensors; Sensitivity; Monitoring; Sensor phenomena and characterization; Power transmission lines; Mechanical sensors; Feature extraction; Crack detection; guided wave (GW); periodically loaded transmission line (PLTL); propagation constant; structural health monitoring (SHM); SPLIT-RING RESONATOR; SURFACE CRACKS; SENSOR; PROBE;
D O I
10.1109/JSEN.2023.3242672
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
Cracks are commonly occurring defects in metal. Crack monitoring in large-area infrastructures requires numerous sensors and thus increases the weight, complexity, and integrity problem for wire deployment. The electromagnetic (EM) resonator-based sensor enjoys good sensitivity but suffers limited coverage. The perturbation theory governing crack detection for EM resonator-based sensors indicates that the uneven field distribution inside the resonator is the bottleneck behind the sensitivity and coverage. In this article, the EM energy is confined underneath the resonator but evenly distributed along the transmission line through periodically loading interleaved step impedance resonators (SIRs) on the two sides of a microstrip line. In this way, the sensitivity can be maintained and the coverage can be extended. An averaged attenuation constant is studied and extracted as a feature for crack characterization. The measurement normalized sensitivity is -0.057 N.U./mm(2). This article provides a paradigm to bridge the gap between local and global monitoring. The proposed sensor can be used for monitoring potential cracks of in-service complex components.
引用
收藏
页码:6799 / 6809
页数:11
相关论文
共 50 条
  • [31] Distributed Transmission Line Ice-Coating Recognition System Based on BOTDR Temperature Monitoring
    Sun, Jinxiang
    Zhang, Zhiguo
    Li, Yuemei
    Yan, Zhehao
    Zhai, Tong
    Li, Luming
    Xiao, Ziyang
    JOURNAL OF LIGHTWAVE TECHNOLOGY, 2021, 39 (12) : 3967 - 3973
  • [32] Deep learning based crack damage detection technique for thin plate structures using guided lamb wave signals
    Liu, Heng
    Zhang, Yunfeng
    SMART MATERIALS AND STRUCTURES, 2020, 29 (01)
  • [33] Stress Online Monitoring Method Based on Multifrequency SH0 Guided Wave Information Fusion
    Shi, Weijia
    Li, Jiaxin
    Deng, Sen
    Wang, Shaokai
    Zhao, Bo
    Tan, Jiubin
    IEEE TRANSACTIONS ON INSTRUMENTATION AND MEASUREMENT, 2023, 72
  • [34] Stress Online Monitoring Method Based on Multifrequency SH0 Guided Wave Information Fusion
    Shi, Weijia
    Li, Jiaxin
    Deng, Sen
    Wang, Shaokai
    Zhao, Bo
    Tan, Jiubin
    IEEE TRANSACTIONS ON INSTRUMENTATION AND MEASUREMENT, 2023, 72
  • [35] Investigating the suitability of the matched fiber Bragg grating approach for guided wave based structural health monitoring
    Soman, Rohan
    Moaf, Farzam Omidi
    Fiborek, Piotr
    Kudela, Pawel
    Kurpinska, Marzena
    MEASUREMENT, 2025, 242
  • [36] Analysis of transmission line wind vibration monitoring based on a multi parameter distributed optical fiber sensor
    Yang F.
    Tang X.
    Yin W.
    Wang M.
    Dianli Xitong Baohu yu Kongzhi/Power System Protection and Control, 2022, 50 (11): : 169 - 177
  • [37] Guided wave resonance-based digital holographic microscopy for high-sensitivity monitoring of the refractive index
    Wang, Chunyu
    Mi, Jingyu
    Lu, Hua
    Shi, Shouhao
    Zhao, Jianxu
    Li, Dikun
    Zhang, Jiwei
    Zheng, Jiadeng
    Zhao, Jianlin
    OPTICS LETTERS, 2024, 49 (06) : 1453 - 1456
  • [38] Design and implementation of a digital smart layer for ultrasonic-guided wave-based structural health monitoring
    Wei, Juntao
    Sun, Lingyu
    Peng, Chang
    Fan, Longqing
    Teng, Feiyu
    Hao, Wei
    Zhang, Lei
    Sui, Qingmei
    Jiang, Mingshun
    STRUCTURAL HEALTH MONITORING-AN INTERNATIONAL JOURNAL, 2024,
  • [39] Guided Lamb wave-based structural health monitoring using a novel wave packet tracing method for damage localization and size quantification
    Kim, Inho
    Chattopadhyay, Aditi
    JOURNAL OF INTELLIGENT MATERIAL SYSTEMS AND STRUCTURES, 2015, 26 (18) : 2515 - 2530
  • [40] System for monitoring partial discharges occurring in overhead power transmission line insulators based on ultraviolet radiation registration
    Fracz, P.
    INSIGHT, 2016, 58 (07) : 360 - 366