Design and Implementation of a Ku-Band High-Precision Blackbody Calibration Target

被引:2
|
作者
Liu, Jie [1 ]
Sun, Zhenlin [1 ]
Sun, Guangmin [1 ]
Li, Yu [1 ]
Cao, Tong [1 ]
Tang, Wenjie [1 ]
机构
[1] Beijing Univ Technol, Fac Informat Technol, Beijing 100124, Peoples R China
基金
中国国家自然科学基金;
关键词
blackbody calibration target; high emissivity; high temperature uniformity; finite element method; EMISSIVITY; SCATTERING; ARRAY;
D O I
10.3390/mi14010018
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
Microwave radiometers can be used in human tissue temperature measurement scenarios due to the advantages of non-destructive and non-contact temperature measurement. However, their accuracy often cannot meet the needs of practical applications. In this paper, a Ku-Band high-precision blackbody calibration target is designed to provide calibration for microwave radiometers and meet the requirements of a high temperature-measurement accuracy and high temperature-measurement resolution. From a practical application point of view, the blackbody calibration target needs to have the characteristics of high emissivity and high temperature uniformity. However, previous studies on blackbody calibration targets often focused on the scattering characteristics or temperature uniformity of the calibration target separately, and thus lack a comprehensive consideration of the two characteristics. In this paper, the electromagnetic scattering model and the temperature-distribution model of the calibration target are established through the multi-physical simulation combined with the Finite Element Method. Then, according to the simulation results of the two characteristic models, the structural parameters and composition of the coated cone array are continuously optimized. In addition, to achieve high-precision temperature control of the blackbody calibration target, this paper studies three PID controller parameter self-tuning algorithms, namely, BP-PID, PSO-PID and Fuzzy-PID for the optimal parameter tuning problem of traditional PID algorithms and determines the optimal temperature-control algorithm by comparing the performance of heating and cooling processes. Then, the blackbody calibration target is processed and manufactured. The arch test system is used to validate the reflectance of the calibration target, the emissivity is calculated indirectly, and the temperature-distribution uniformity of the temperature-control panel of the calibration target is tested by a multi-point distribution method. Finally, the uncertainty of the brightness temperature of the blackbody calibration target is analyzed.
引用
收藏
页数:19
相关论文
共 50 条
  • [21] Design and cold-testing of a high gain, Ku-band gyroklystron
    Lawson, W
    Hogan, B
    Gebeyehu, N
    Krumrine, M
    Purohit, P
    Stamatiou, I
    Tiwari, S
    IRMMW-THz2005: The Joint 30th International Conference on Infrared and Millimeter Waves and 13th International Conference on Terahertz Electronics, Vols 1 and 2, 2005, : 655 - 656
  • [22] High-Precision Wavelength Calibration of Wide-Band Monochromator
    Zhang Zi-hui
    Wang Shu-rong
    Huang Yu
    Li Bo
    Yu Xiang-yang
    Lin Guan-yu
    SPECTROSCOPY AND SPECTRAL ANALYSIS, 2012, 32 (10) : 2870 - 2874
  • [23] High Cross Polarized Ku-Band OMT Design for SNG Vehicles
    Bostan, S. M.
    Torpi, H.
    Urbina, J. V.
    2013 US NATIONAL COMMITTEE OF URSI NATIONAL RADIO SCIENCE MEETING (USNC-URSI NRSM), 2013,
  • [24] DESIGN AND DEVELOPMENT OF HIGH-POWER KU-BAND JUNCTION CIRCULATORS
    ALEXANDER, IM
    FLETT, KL
    IEEE TRANSACTIONS ON MAGNETICS, 1977, 13 (05) : 1255 - 1257
  • [25] Polarimetric Calibration of the Ku-Band Advanced Polarimetric Radar Interferometer
    Baffelli, Simone
    Frey, Othmar
    Werner, Charles
    Hajnsek, Irena
    IEEE TRANSACTIONS ON GEOSCIENCE AND REMOTE SENSING, 2018, 56 (04): : 2295 - 2311
  • [26] Design and Implementation of RSLA Antenna for Mobile DBS Application in Ku-Band Downlink Direction
    Suryana, Joko
    Kusuma, Dimas Budiarto
    5TH INTERNATIONAL CONFERENCE ON ELECTRICAL ENGINEERING AND INFORMATICS 2015, 2015, : 341 - 345
  • [27] High-efficiency Ku-band oscillators
    McSpadden, JO
    Fan, L
    Chang, K
    IEEE TRANSACTIONS ON MICROWAVE THEORY AND TECHNIQUES, 1998, 46 (10) : 1566 - 1571
  • [28] Moving target imaging by both Ka-band and Ku-band high-resolution radars
    Zhang, Yunhua
    Zhai, Wenshuai
    Zhang, Xiangkun
    Shi, Xiaojin
    Gu, Xiang
    Jiang, Jingshan
    SAR IMAGE ANALYSIS, MODELING, AND TECHNIQUES XI, 2011, 8179
  • [29] High-precision calibration of spectrographs
    Wilken, T.
    Lovis, C.
    Manescau, A.
    Steinmetz, T.
    Pasquini, L.
    Lo Curto, G.
    Haensch, T. W.
    Holzwarth, R.
    Udem, Th.
    MONTHLY NOTICES OF THE ROYAL ASTRONOMICAL SOCIETY, 2010, 405 (01) : L16 - L20
  • [30] DESIGN OF A KU-BAND COMPACT CORRUGATED HORN WITH HIGH GAUSSIAN BEAM EFFICIENCY
    Zhang, T. -L.
    Yan, Z. -H.
    Fan, F. -F.
    Li, B.
    JOURNAL OF ELECTROMAGNETIC WAVES AND APPLICATIONS, 2011, 25 (01) : 123 - 129