Inappropriate shock incidence in patients with subcutaneous implantable cardioverter-defibrillators with concomitant cardiac implantable electronic devices: A single-center cohort study

被引:0
|
作者
Okazaki, Makiko [1 ,2 ]
Sahashi, Yuki [3 ]
Nagase, Takahiko [4 ]
Inoue, Kanki [4 ]
Sekiguchi, Yukio [4 ]
Nitta, Junichi [4 ]
Shinoda, Satoru [5 ]
Shimizu, Sayuri [2 ]
Kuroki, Makoto [2 ]
Isobe, Mitsuaki [6 ]
Mihara, Takahiro [2 ,7 ]
机构
[1] Sakakibara Heart Inst, Dept Clin Engn, Fuchu, Tokyo, Japan
[2] Yokohama City Univ, Grad Sch Data Sci, Dept Hlth Data Sci, Yokohama, Kanagawa, Japan
[3] Gifu Univ, Grad Sch Med, Dept Cardiol, Gifu, Japan
[4] Sakakibara Heart Inst, Dept Cardiol, Fuchu, Tokyo, Japan
[5] Yokohama City Univ, Sch Med, Dept Biostat, Yokohama, Kanagawa, Japan
[6] Sakakibara Heart Inst, Fuchu, Tokyo, Japan
[7] Yokohama City Univ, Grad Sch Data Sci, Dept Hlth Data Sci, Yokohama 2360027, Japan
来源
关键词
cardiac implantable electronic devices; concomitant; inappropriate shock; pacing; subcutaneous implantable cardioverter-defibrillator; ICD; OUTCOMES;
D O I
10.1111/pace.14887
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
BackgroundSubcutaneous implantable cardioverter defibrillators (S-ICDs) are occasionally used in combination with other cardiac implantable electronic devices (CIEDs). However, whether the incidence of inappropriate shock increases in patients with S-ICDs and concomitant CIEDs remains unclear. This study aimed to investigate the association between the concomitant use of CIEDs and the incidence of inappropriate shock in patients with current-generation S-ICDs.MethodsA total of 127 consecutive patients received an S-ICD. Patients were assigned to two groups depending on concomitant use of CIEDs at the time of S-ICD implantation: patients without other CIEDs (non-combined group, 106 patients) and patients with other CIEDs (combined group, 21 patients). CIEDs included pacemakers, implantable cardioverter defibrillators, cardiac resynchronization therapy pacemakers, and cardiac resynchronization therapy defibrillators. The primary outcome was inappropriate shock, defined as a shock other than ventricular arrhythmia. Hazard ratios and 95% confidence intervals were calculated using a time-varying Cox proportional hazards model which was adjusted for age because age differed between the groups and could be a confounder.ResultsDuring a median follow-up period of 2.2 years (interquartile range, 1.0-3.4 years), inappropriate shock events occurred in 17 (16%) and five (19%) patients of the non-combined and combined groups, respectively. While the age-adjusted hazard ratio for inappropriate shock was 24% higher in the combined than in the non-combined group (hazard ratio = 1.24, 95% confidence interval, 0.39-3.97), this difference was insignificant (p = .71).ConclusionThe incidence of inappropriate shock did not differ between patients with and without concomitant use of CIEDs, suggesting that S-ICDs could potentially be combined with other CIEDs without increasing the number of inappropriate shocks. Further studies are warranted to confirm the safety and feasibility of concomitant use of S-ICDs and CIEDs.
引用
收藏
页码:131 / 138
页数:8
相关论文
共 50 条
  • [21] Reduction of Inappropriate Shocks Over Time in Hypertrophic Cardiomyopathy Patients With Subcutaneous Implantable Cardioverter-Defibrillators
    Narayanan, Chockalingam
    Gionfriddo, William
    Shrestha, Srijan
    Koethe, Benjamin
    Katcher, Benjamin
    Garlitski, Ann
    Weinstock, Jonathan
    Homoud, Munther
    Maron, Barry
    Maron, Martin S.
    Rowin, Ethan J.
    Madias, Christopher
    CIRCULATION, 2021, 144
  • [22] INCIDENCE AND DETERMINANTS OF INAPPROPRIATE SHOCK IN HYPERTROPHIC CARDIOMYOPATHY PATIENTS WITH SUBCUTANEOUS IMPLANTABLE DEFIBRILLATORS
    Dale, Zack
    Gray, Andrew
    Elman, Miriam
    Carrassa, Gianmarco
    Pieragnoli, Paolo
    Ricciardi, Giuseppe
    Reza, Nosheen
    Ustunkaya, Tuna
    Papoutsidakis, Nikolaos
    Jacoby, Daniel
    Frankel, David S.
    Owens, Anjali
    Iacopo, Olivotto
    Heitner, Stephen B.
    Nazer, Babak
    JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 2020, 75 (11) : 320 - 320
  • [23] PREDICTORS OF INAPPROPRIATE THERAPY IN PATIENTS WITH IMPLANTABLE CARDIOVERTER-DEFIBRILLATORS AND CHAGAS' CARDIOMYOPATHY
    Miranda, R. I.
    Femenia, F.
    Lopez, J.
    Serra, J.
    Muratore, C.
    Valentino, M.
    Retyk, E.
    Galizio, N.
    Rodriguez, C.
    Baranchuk, A.
    CANADIAN JOURNAL OF CARDIOLOGY, 2011, 27 (05) : S260 - S261
  • [24] Mortality, Appropriate and Inappropriate Shock in Patients with Ischemic Heart Disease and Implantable Cardioverter-Defibrillators for Primary Prevention: A Nationwide Cohort Study
    Weeke, Peter
    Johansen, Jens B.
    Jorgensen, Ole D.
    Nielsen, Jens C.
    Moller, Mogens
    Videbaek, Regitze
    Hojgaard, Michael V.
    Riahi, Sam
    Jacobsen, Peter K.
    CIRCULATION, 2012, 126 (21)
  • [25] Propofol dose and efficacy of defibrillation testing during implantation of subcutaneous implantable cardioverter-defibrillators: A retrospective, single center cohort study
    Trolese, Luca
    Dall'Aglio, Pietro Bernardo
    Steinfurt, Johannes
    Gressler, Alexander
    Faber, Thomas
    Cipriani, Alberto
    Migliore, Federico
    Westermann, Dirk
    Hilgendorf, Ingo
    Jaeckel, Markus
    JOURNAL OF CARDIOVASCULAR ELECTROPHYSIOLOGY, 2023, 34 (02) : 420 - 428
  • [26] Effect of concomitant antiarrhythmic therapy on survival in patients with implantable cardioverter-defibrillators
    Ho, AT
    Pai, S
    Timothy, P
    Pai, RG
    CIRCULATION, 2002, 106 (19) : 408 - 408
  • [27] The subcutaneous implantable cardioverter-defibrillator: first single-center experience with concomitant implantable pulse generators
    Kuschyk, J.
    Stach, K.
    Tueluemen, E.
    Rudic, B.
    Liebe, V.
    Schimpf, R.
    Borggrefe, M.
    Roeger, S.
    EUROPEAN JOURNAL OF HEART FAILURE, 2015, 17 : 324 - 324
  • [28] Longitudinal Outcomes of Subcutaneous or Transvenous Implantable Cardioverter-Defibrillators in Older Patients
    Friedman, Daniel J.
    Qin, Li
    Parzynski, Craig
    Heist, E. Kevin
    Russo, Andrea M.
    Ranasinghe, Isuru
    Zeitler, Emily P.
    Minges, Karl E.
    Akar, Joseph G.
    Freeman, James V.
    Curtis, Jeptha P.
    Al-Khatib, Sana M.
    JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 2022, 79 (11) : 1050 - 1059
  • [29] EFFICACY OF IMPLANTABLE CARDIOVERTER-DEFIBRILLATORS IN PATIENTS AWAITING CARDIAC TRANSPLANTATION
    PODCZECK, A
    HIEF, C
    JAKL, G
    FROHNER, K
    NURNBERG, M
    KALTENBRUNNER, W
    VEIT, F
    LAUFER, G
    STEINBACH, K
    WIENER KLINISCHE WOCHENSCHRIFT, 1995, 107 (16) : 485 - 488
  • [30] Physiologic cardiac pacing in patients with contemporary implantable cardioverter-defibrillators
    Iskos, D
    Fahy, GJ
    Lurie, KG
    Sakaguchi, S
    Collins, JM
    Fetter, J
    Benditt, DG
    AMERICAN JOURNAL OF CARDIOLOGY, 1998, 82 (01): : 66 - 71