Monitoring System for Operating Variables in Incubators in the Neonatology Service of a Highly Complex Hospital through the Internet of Things (IoT)

被引:2
作者
Aya-Parra, Pedro Antonio [1 ]
Rodriguez-Orjuela, Andres Jacob [1 ,2 ]
Torres, Viviana Rodriguez [3 ]
Hernandez, Nidia Patricia Cordoba [4 ]
Castellanos, Natalia Martinez [4 ]
Sarmiento-Rojas, Jefferson [1 ]
机构
[1] Univ Rosario, Sch Med & Hlth Sci, Biomed Engn Program, Bogota 111711, Colombia
[2] Escuela Colombiana Ingn Julio Garavito, Engn Fac, Biomed Engn Program, Bogota 110111, Colombia
[3] Hosp Univ Mayor Mederi, Dept Neonatol, Bogota 110111, Colombia
[4] Hosp Univ Mayor Mederi, Dept Ingn Biomed, Bogota 110111, Colombia
关键词
neonatal care; incubators; clinical innovation; IoMT; patient safety; medical bioinstrumentation; IoT;
D O I
10.3390/s23125719
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
Background: Around 15 million premature babies are born annually, requiring specialized care. Incubators are vital for maintaining their body temperature, which is crucial for their well-being. Ensuring optimal conditions in incubators, including constant temperature, oxygen control, and comfort, is essential for improving the care and survival rates of these infants. Methods: To address this, an IoT-based monitoring system was developed in a hospital setting. The system comprised hardware components such as sensors and a microcontroller, along with software components including a database and a web application. The microcontroller collected data from the sensors, which was then transmitted to a broker via WiFi using the MQTT protocol. The broker validated and stored the data in the database, while the web application provided real-time access, alerts, and event recording. Results: Two certified devices were created, employing high quality components. The system was successfully implemented and tested in both the biomedical engineering laboratory and the neonatology service of the hospital. The results of the pilot test supported the concept of IoT-based technology, demonstrating satisfactory responses in temperature, humidity, and sound variables within the incubators. Conclusions: The monitoring system facilitated efficient record traceability, allowing access to data over various timeframes. It also captured event records (alerts) related to variable problems, providing information on duration, date, hour, and minutes. Overall, the system offered valuable insights and enhanced monitoring capabilities for neonatal care.
引用
收藏
页数:18
相关论文
共 28 条
[1]  
ADMP401 Analog.com, US
[2]   Sound reduction management in the neonatal intensive care unit for preterm or very low birth weight infants [J].
Almadhoob, Abdulraoof ;
Ohlsson, Arne .
COCHRANE DATABASE OF SYSTEMATIC REVIEWS, 2020, (01)
[3]  
Almaiah MA, 2022, SENSORS-BASEL, V22, DOI 10.3390/s22041448
[4]  
[Anonymous], Nacimientos prematuros
[5]  
Bell C., 2016, MYSQL INTERNET THING, P79
[6]  
Bengiovanni T., 2020, P 2020 5 INT C SMART, P1, DOI [10.23919/SpliTech49282.2020.9243821, DOI 10.23919/SPLITECH49282.2020.9243821]
[7]  
Digiconomist, US
[8]  
EMQ Technologies Inc, EMQX WORLDS 1 OPEN S
[9]  
espressif, ESP32 C3 ESPRESSIFCO
[10]  
Fernanda L., ABC CUIDADO ENFERMER