Factors influencing size-specific dose estimates of selected computed tomography protocols at two clinical practices in South Africa

被引:2
作者
Sebelego, Ida-Keshia [1 ]
Acho, Sussan [2 ]
van der Merwe, Belinda [1 ]
Rae, William I. D. [2 ,3 ]
机构
[1] Cent Univ Technol, Fac Hlth & Environm Sci, Dept Clin Sci, ZA-9301 Bloemfontein, South Africa
[2] Univ Free State, Fac Hlth Sci, Dept Med Phys, ZA-9300 Bloemfontein, South Africa
[3] Prince Wales Hosp, Med Imaging Dept, Randwick 2133, Australia
基金
新加坡国家研究基金会;
关键词
DIAGNOSTIC REFERENCE LEVELS; TUBE CURRENT MODULATION; IMAGE QUALITY; CT; IMPACT;
D O I
10.1093/rpd/ncad059
中图分类号
X [环境科学、安全科学];
学科分类号
08 ; 0830 ;
摘要
The study aimed to determine the factors that impact the size-specific dose estimate (SSDE) for computed tomography (CT) examinations of the chest-abdomen-pelvis and abdomen-pelvis protocols in two clinical radiology practices and evaluate the image quality of these protocols. Imaging parameters, protocols, dose metrics from the CT units and size-related parameters to calculate the SSDE were documented. The image quality of the CT images was assessed using an image subtraction algorithm. The SSDE increased as the volumetric CT dose index (CTDIvol), and the patient's body mass index increased, respectively. Significant differences (p < 0.001) occurred between the two hospitals regarding image quality. However, these differences were not indicative of differences in the diagnostic performances for task-based imaging protocols. Different clinical protocols should be reviewed to optimise dose. The inclusion of the pre-monitoring sequence, age of the machine and the scan requisition parameters impacted the SSDEs. Image quality should be assessed to evaluate the consistency of image quality between protocols applied by different CT units when assessing SSDEs.
引用
收藏
页码:588 / 602
页数:15
相关论文
共 47 条
[41]   Diagnostic Reference Levels for computed tomography in Austria: A 2018 nationwide survey on adult patients [J].
Wachabauer, David ;
Roethlin, Florian ;
Moshammer, Hanns Michael ;
Homolka, Peter .
EUROPEAN JOURNAL OF RADIOLOGY, 2020, 125
[42]   The application of automatic tube current modulation (ATCM) on image quality and radiation dose at abdominal computed tomography (CT): A phantom study [J].
Wang, Qian ;
Zhao, Xinming ;
Song, Junfeng ;
Guo, Ning ;
Zhu, Ying ;
Liu, Jianxin ;
Qi, Weiwei ;
Wu, Jing ;
Liang, Yuan ;
Feng, Shichao ;
Hu, Mancang ;
Zhou, Chunwu ;
Wang, Xiaoying ;
Hong, Nan .
JOURNAL OF X-RAY SCIENCE AND TECHNOLOGY, 2013, 21 (04) :453-464
[43]  
World Health Organization (WHO), 2022, Body mass index-BMI
[44]   Size-Specific Dose Estimates of Radiation Based on Body Weight and Body Mass Index for Chest and Abdomen-Pelvic CTs [J].
Xu, Jian ;
Wang, Xiangquan ;
Yang, Panfeng ;
Luo, Kuangnan ;
He, Xiaolong .
BIOMED RESEARCH INTERNATIONAL, 2020, 2020
[45]   Evaluation of Impact of Factors Affecting CT Radiation Dose for Optimizing Patient Dose Levels [J].
Yang, Ching-Ching .
DIAGNOSTICS, 2020, 10 (10)
[46]   LOCAL STUDY OF DIAGNOSTIC REFERENCE LEVELS FOR COMPUTED TOMOGRAPHY EXAMINATIONS OF ADULT PATIENTS IN IZMIR, TURKEY [J].
Yurt, Aysegul ;
Ozsoykal, Ismail ;
Kandemir, Recep ;
Ada, Emel .
RADIATION PROTECTION DOSIMETRY, 2020, 190 (04) :446-451
[47]   Effects of the Use of Automatic Tube Current Modulation on Patient Dose and Image Quality in Computed Tomography [J].
Yurt, Aysegul ;
Ozsoykal, Ismail ;
Obuz, Funda .
MOLECULAR IMAGING AND RADIONUCLIDE THERAPY, 2019, 28 (03) :96-103