Factors influencing size-specific dose estimates of selected computed tomography protocols at two clinical practices in South Africa

被引:2
作者
Sebelego, Ida-Keshia [1 ]
Acho, Sussan [2 ]
van der Merwe, Belinda [1 ]
Rae, William I. D. [2 ,3 ]
机构
[1] Cent Univ Technol, Fac Hlth & Environm Sci, Dept Clin Sci, ZA-9301 Bloemfontein, South Africa
[2] Univ Free State, Fac Hlth Sci, Dept Med Phys, ZA-9300 Bloemfontein, South Africa
[3] Prince Wales Hosp, Med Imaging Dept, Randwick 2133, Australia
基金
新加坡国家研究基金会;
关键词
DIAGNOSTIC REFERENCE LEVELS; TUBE CURRENT MODULATION; IMAGE QUALITY; CT; IMPACT;
D O I
10.1093/rpd/ncad059
中图分类号
X [环境科学、安全科学];
学科分类号
08 ; 0830 ;
摘要
The study aimed to determine the factors that impact the size-specific dose estimate (SSDE) for computed tomography (CT) examinations of the chest-abdomen-pelvis and abdomen-pelvis protocols in two clinical radiology practices and evaluate the image quality of these protocols. Imaging parameters, protocols, dose metrics from the CT units and size-related parameters to calculate the SSDE were documented. The image quality of the CT images was assessed using an image subtraction algorithm. The SSDE increased as the volumetric CT dose index (CTDIvol), and the patient's body mass index increased, respectively. Significant differences (p < 0.001) occurred between the two hospitals regarding image quality. However, these differences were not indicative of differences in the diagnostic performances for task-based imaging protocols. Different clinical protocols should be reviewed to optimise dose. The inclusion of the pre-monitoring sequence, age of the machine and the scan requisition parameters impacted the SSDEs. Image quality should be assessed to evaluate the consistency of image quality between protocols applied by different CT units when assessing SSDEs.
引用
收藏
页码:588 / 602
页数:15
相关论文
共 47 条
[1]   Correlation of size-dependent conversion factor and body-mass-index using size-specific dose estimates formalism in CT examinations [J].
Alikhani, Babak ;
Getzin, Tobias ;
Kaireit, Till Frederik ;
Ringe, Kristina Imeen ;
Jamali, Leila ;
Wacker, Frank ;
Werncke, Thomas ;
Raatschen, Hans-Juergen .
EUROPEAN JOURNAL OF RADIOLOGY, 2018, 100 :130-134
[2]  
American Association of Physicists in Medicine (AAPM), 2011, SIZE SPEC DOS EST SS
[3]  
Anam C, 2017, AT INDONES, V43, P55, DOI 10.17146/aij.2017.617
[4]   The impact of patient table on size-specific dose estimate (SSDE) [J].
Anam, Choirul ;
Haryanto, Freddy ;
Widita, Rena ;
Arif, Idam ;
Dougherty, Geoff ;
McLean, Donald .
AUSTRALASIAN PHYSICAL & ENGINEERING SCIENCES IN MEDICINE, 2017, 40 (01) :153-158
[5]   Quality assurance in CT: implementation of the updated national diagnostic reference levels using an automated CT dose monitoring system [J].
Appel, E. ;
Kroepil, P. ;
Bethge, O. T. ;
Aissa, J. ;
Thomas, C. ;
Antoch, G. ;
Boos, J. .
CLINICAL RADIOLOGY, 2018, 73 (07) :677.e13-677.e20
[6]   ACCURACY OF SIZE-SPECIFIC DOSE ESTIMATE CALCULATION FROM CENTER SLICE IN COMPUTED TOMOGRAPHY [J].
Boos, Johannes ;
Kroepil, Patric ;
Bethge, Oliver Th. ;
Aissa, Joel ;
Schleich, Christoph ;
Sawicki, Lino Morris ;
Heinzler, Niklas ;
Antoch, Gerald ;
Thomas, Christoph .
RADIATION PROTECTION DOSIMETRY, 2018, 178 (01) :8-19
[7]   Does body mass index outperform body weight as a surrogate parameter in the calculation of size-specific dose estimates in adult body CT? [J].
Boos, Johannes ;
Lanzman, Rotem S. ;
Heusch, Philipp ;
Aissa, Joel ;
Schleich, Christoph ;
Thomas, Christoph ;
Sawicki, Lino M. ;
Antoch, Gerald ;
Kroepil, Patric .
BRITISH JOURNAL OF RADIOLOGY, 2016, 89 (1059)
[8]   Diagnostic reference levels and median doses for common clinical indications of CT: findings from an international registry [J].
Bos, Denise ;
Yu, Sophronia ;
Luong, Jason ;
Chu, Philip ;
Wang, Yifei ;
Einstein, Andrew J. ;
Starkey, Jay ;
Delman, Bradley N. ;
Duong, Phuong-Anh T. ;
Das, Marco ;
Schindera, Sebastian ;
Goode, Allen R. ;
MacLeod, Fiona ;
Wetter, Axel ;
Neill, Rebecca ;
Lee, Ryan K. ;
Roehm, Jodi ;
Seibert, James A. ;
Cervantes, Luisa F. ;
Kasraie, Nima ;
Pike, Pavlina ;
Pahwa, Anokh ;
Jeukens, Cecile R. L. P. N. ;
Smith-Bindman, Rebecca .
EUROPEAN RADIOLOGY, 2022, 32 (03) :1971-1982
[9]   National indication-based diagnostic reference level values in computed tomography: Preliminary results from Ghana [J].
Botwe, Benard Ohene ;
Schandorf, Cyril ;
Inkoom, Stephen ;
Faanu, Augustine ;
Rolstadaas, Linn ;
Goa, Pal Erik .
PHYSICA MEDICA-EUROPEAN JOURNAL OF MEDICAL PHYSICS, 2021, 84 :274-284
[10]   Local clinical diagnostic reference levels for chest and abdomen CT examinations in adults as a function of body mass index and clinical indication: a prospective multicenter study [J].
Brat, Hugues ;
Zanca, Federica ;
Montandon, Stephane ;
Racine, Damien ;
Rizk, Benoit ;
Meicher, Eric ;
Fournier, Dominique .
EUROPEAN RADIOLOGY, 2019, 29 (12) :6794-6804