Vaginal Applicators in High-Dose Rate Brachytherapy for Endometrial Carcinoma: A Dosimetric Study

被引:0
|
作者
Khan, Aijaz Ahmad [1 ,2 ]
Vijay, Anuj [1 ]
Wani, Shaqul Qamar [3 ]
Haq, Malik Mohib-ul [2 ]
机构
[1] GLA Univ, Inst Appl Sci & Humanities, Dept Phys, Chaumuhan, Uttar Pradesh, India
[2] Sherikashmir Inst Med Sci, Dept Radiol Phys & Bioengn, Srinagar, India
[3] Sherikashmir Inst Med Sci, Dept Radiat Oncol, Srinagar, India
来源
TURK ONKOLOJI DERGISI-TURKISH JOURNAL OF ONCOLOGY | 2023年 / 38卷 / 02期
关键词
Brachytherapy; Elasto-Gel; overestimation of dose; treatment planning system; vaginal applicators; EXTERNAL-BEAM RADIOTHERAPY; QUALITY-OF-LIFE; RADIATION-THERAPY; STAGE-I; CANCER; PORTEC-2; TRIAL; AAPM; IR-192;
D O I
10.5505/tjo.2022.3765
中图分类号
R73 [肿瘤学];
学科分类号
100214 ;
摘要
OBJECTIVE Intracavitary brachytherapy is one of the most important methods of gynecological cancer treatment. The effect of attenuation by the applicators is not considered in the dose calculation method released by the AAPM TG-43. In this study, the attenuation due to various segmented vaginal cylinders made up of polyetheretherketone was measured. METHODS A plan created by the treatment planning system (TPS) for the patient was executed using Gafchromic films that were taped on the surface of the applicator, and the dose recorded on the films was measured. The same plan was also executed using a well-type ionization chamber. First, a water equivalent material, Elasto-Gel was used in a well-type ionization chamber for charge collection, and then a segmented vaginal cylinder was used for charge collection measurement; thus, the attenuation due to the various segmented vaginal cylinders was obtained. RESULTS The doses recorded on the Gafchromic films were measured and showed that the TPS overestimated the dose for the segmented vaginal applicators and that the maximum overestimation of the dose was 4.75% for 35 mm diameter vaginal cylinders. This was further confirmed by calculating the percentage attenuation due to vaginal cylinders using a well-type ionization chamber. CONCLUSION Due to the attenuation by the various applicators used in vaginal vault brachytherapy, it can be concluded that due to overestimation of dose by the TPS, the dose actually received by the target and the organs at risk in vaginal vault brachytherapy are less and needs to be considered for actual dose estimation.
引用
收藏
页码:191 / 200
页数:10
相关论文
共 50 条
  • [1] Dosimetric impact of cylinder size in high-dose rate vaginal cuff brachytherapy (VCBT) for primary endometrial cancer
    Zhang, Hualin
    Gopalakrishnan, Mahesh
    Lee, Plato
    Kang, Zhuang
    Sathiaseelan, Vythialingam
    JOURNAL OF APPLIED CLINICAL MEDICAL PHYSICS, 2016, 17 (05): : 262 - 272
  • [2] Treatment of Vaginal Recurrences in Endometrial Carcinoma by High-dose-rate Brachytherapy
    Sorbe, Bengt
    Soderstrom, Karin
    ANTICANCER RESEARCH, 2013, 33 (01) : 241 - 247
  • [3] High dose rate vaginal brachytherapy in endometrial cancer after surgery
    Moreau-Claeys, M. -V.
    Brunaud, C.
    Hoffstetter, S.
    Buchheit, I.
    Peiffert, D.
    CANCER RADIOTHERAPIE, 2011, 15 (03): : 169 - 175
  • [4] Predictors of vaginal stenosis after intravaginal high-dose-rate brachytherapy for endometrial carcinoma
    Park, Henry S.
    Ratner, Elena S.
    Lucarelli, Laura
    Polizzi, Shawn
    Higgins, Susan A.
    Damast, Shari
    BRACHYTHERAPY, 2015, 14 (04) : 464 - 470
  • [5] DOSIMETRIC EFFECTS OF AIR POCKETS AROUND HIGH-DOSE RATE BRACHYTHERAPY VAGINAL CYLINDERS
    Richardson, Susan
    Palaniswaamy, Geethpriya
    Grigsby, Perry W.
    INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 2010, 78 (01): : 276 - 279
  • [6] Dosimetric analysis of intracavitary brachytherapy applicators: a practical study
    Khan, Aijaz A.
    Vijay, Anuj
    Wani, Shaqul Qamar
    Haq, Malik M.
    RADIATION ONCOLOGY JOURNAL, 2022, 40 (03): : 180 - 191
  • [7] Dosimetric comparison between different applicators for high dose rate gynecologic brachytherapy
    Portocarrero-Bonifaz, Andres
    Syed, Salman
    Kassel, Maxwell
    McKenzie, Grant W.
    Shah, Vishwa M.
    Forry, Bryce
    Masters, Adrianna H.
    Gaskins, Jeremy T.
    Sowards, Keith T.
    Silva, Scott R.
    RADIOTHERAPY AND ONCOLOGY, 2024, 194 : S260 - S262
  • [8] High dose rate vaginal brachytherapy in early stage endometrial carcinoma: Preliminary analysis
    Hong, JJ
    Yacoub, SF
    Blevins, JC
    Kuban, DA
    ElMahdi, AM
    AMERICAN JOURNAL OF CLINICAL ONCOLOGY-CANCER CLINICAL TRIALS, 1997, 20 (03): : 254 - 258
  • [9] Toxicity and outcomes associated with high-dose rate brachytherapy for medically inoperable endometrial cancer
    Yaney, Alexander
    Healy, Erin
    Wald, Patrick
    Olsen, Meghan
    Pan, Xueliang
    Martin, Douglas
    Quick, Allison
    BRACHYTHERAPY, 2021, 20 (02) : 368 - 375
  • [10] DOSIMETRIC IMPACT OF INTERFRACTION CATHETER MOVEMENT IN HIGH-DOSE RATE PROSTATE BRACHYTHERAPY
    Foster, William
    Cunha, J. Adam M.
    Hsu, I-Chow
    Weinberg, Vivan
    Krishnamurthy, Devan
    Pouliot, Jean