A quantitative clinical evaluation of simultaneous reconstruction of attenuation and activity in time-of-flight PET

被引:1
作者
Zhang, Haiqiong [1 ,2 ]
Wang, Jingnan [1 ]
Li, Nan [3 ]
Zhang, Yue [3 ]
Cui, Jie [3 ]
Huo, Li [1 ]
Zhang, Hui [3 ,4 ]
机构
[1] Peking Union Med Coll Hosp, Chinese Acad Med Sci, Dept Nucl Med, State Key Lab Complex Severe & Rare Dis,Beijing Ke, Beijing 100730, Peoples R China
[2] Peking Union Med Coll Hosp, Chinese Acad Med Sci, Med Sci Res Ctr MRC, Beijing 100730, Peoples R China
[3] SinoUn Beijing Healthcare Technol Co Ltd, Beijing 100082, Peoples R China
[4] Tsinghua Univ, Dept Biomed Engn, Beijing 100084, Peoples R China
关键词
TOF-PET; MLAA; CT-OSEM; Quantitative evaluation; IMAGE; MLAA;
D O I
10.1186/s12880-023-00987-7
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
BackgroundThe maximum likelihood activity and attenuation (MLAA) reconstruction algorithm has been proposed to jointly estimate tracer activity and attenuation at the same time, and proven to be a promising solution to the CT attenuation correction (CT-AC) artifacts in PET images. This study aimed to perform a quantitative evaluation and clinical validation of the MLAA method.MethodsA uniform cylinder phantom filled with F-18-FDG solution was scanned to optimize the reconstruction parameters for the implemented MLAA algorithm. 67 patients who underwent whole-body F-18-FDG PET/CT scan were retrospectively recruited. PET images were reconstructed using MLAA and clinical standard OSEM algorithm with CT-AC (CT-OSEM). The mean and maximum standardized uptake values (SUVmean and SUVmax) in regions of interest (ROIs) of organs, high uptake lesions and areas affected by metal implants and respiration motion artifacts were quantitatively analyzed.ResultsIn quantitative analysis, SUVs in patient's organ ROIs between two methods showed R-2 ranging from 0.91 to 0.98 and k ranging from 0.90 to 1.06, and the average SUVmax and SUVmean differences between two methods were within 10% range, except for the lung ROI, which was 10.5% and 16.73% respectively. The average SUVmax and SUVmean differences of a total of 117 high uptake lesions were 7.25% and 7.10% respectively. 20 patients were identified to have apparent respiration motion artifacts in the liver in CT-OSEM images, and the SUVs differences between two methods measured at dome of the liver were significantly larger than measured at middle part of the liver. 10 regions with obvious metal artifacts were identified in CT-OSEM images and the average SUVmean and SUVmax differences in metal implants affected regions were reported to be 52.90% and 56.20% respectively.ConclusionsPET images reconstructed using MLAA are clinically acceptable in terms of image quality as well as quantification and it is a useful tool in clinical practice, especially when CT-AC may cause respiration motion and metal artifacts. Moreover, this study also provides technical reference and data support for the future iteration and development of PET reconstruction technology of SUV accurate quantification.
引用
收藏
页数:13
相关论文
共 50 条
  • [31] Impact of time-of-flight on indirect 3D and direct 4D parametric image reconstruction in the presence of inconsistent dynamic PET data
    Kotasidis, F. A.
    Mehranian, A.
    Zaidi, H.
    PHYSICS IN MEDICINE AND BIOLOGY, 2016, 61 (09) : 3443 - 3471
  • [32] Clinical Evaluation of Zero-Echo-Time Attenuation Correction for Brain 18F-FDG PET/MRI: Comparison with Atlas Attenuation Correction
    Sekine, Tetsuro
    ter Voert, Edwin E. G. W.
    Warnock, Geoffrey
    Buck, Alfred
    Huellner, Martin
    Veit-Haibach, Patrick
    Delso, Gaspar
    JOURNAL OF NUCLEAR MEDICINE, 2016, 57 (12) : 1927 - 1932
  • [33] Simulation study of potential time-of-flight capabilities for a multilayer DOI-PET detector with an independent readout structure
    Watanabe, Mitsuo
    Moriya, Takahiro
    Uchida, Hiroshi
    Omura, Tomohide
    PHYSICS IN MEDICINE AND BIOLOGY, 2021, 66 (18)
  • [34] The value of using heterogeneous detector groups for the development of time-of-flight (TOF) positron emission tomography (PET) systems
    Xin, Zhiqiang
    Kao, Chien-Min
    Liu, Yuqing
    Chen, Xun
    Zhang, Labao
    Wu, Peiheng
    Xie, Qingguo
    BIOMEDICAL PHYSICS & ENGINEERING EXPRESS, 2023, 9 (05)
  • [35] A new method for inpainting of depth maps from time-of-flight sensors based on a modified closing by reconstruction algorithm
    Antonio Garduno-Ramon, Marco
    Ramon Terol-Villalobos, Ivan
    Alfredo Osornio-Rios, Roque
    Alberto Morales-Hernandez, Luis
    JOURNAL OF VISUAL COMMUNICATION AND IMAGE REPRESENTATION, 2017, 47 : 36 - 47
  • [36] Single transmission-line readout method for silicon photomultiplier based time-of-flight and depth-of-interaction PET
    Ko, Guen Bae
    Lee, Jae Sung
    PHYSICS IN MEDICINE AND BIOLOGY, 2017, 62 (06) : 2194 - 2207
  • [37] Proof-of-concept prototype time-of-flight PET system based on high-quantum-efficiency multianode PMTs
    Son, Jeong-Whan
    Kim, Kyeong Yun
    Yoon, Hyun Suk
    Won, Jun Yeon
    Ko, Guen Bae
    Lee, Min Sun
    Lee, Jae Sung
    MEDICAL PHYSICS, 2017, 44 (10) : 5314 - 5324
  • [38] High-resolution time-of-flight PET detector with 100 ps coincidence time resolution using a side-coupled phoswich configuration
    Lee, Min Sun
    Cates, Joshua W.
    Gonzalez-Montoro, Andrea
    Levin, Craig S.
    PHYSICS IN MEDICINE AND BIOLOGY, 2021, 66 (12)
  • [39] Cardiac atrial metabolism quantitative assessment with analog and digital time of flight-PET/computed tomography
    Hesse, Michel
    Marchandise, Sebastien
    Gerber, Bernhard
    Roelants, Veronique
    NUCLEAR MEDICINE COMMUNICATIONS, 2023, 44 (07) : 646 - 652
  • [40] Correction Technique for Cascade Gammas in I-124 Imaging on a Fully-3D, Time-of-Flight PET Scanner
    Surti, Suleman
    Scheuermann, Ryan
    Karp, Joel S.
    IEEE TRANSACTIONS ON NUCLEAR SCIENCE, 2009, 56 (03) : 653 - 660