A quantitative clinical evaluation of simultaneous reconstruction of attenuation and activity in time-of-flight PET

被引:1
作者
Zhang, Haiqiong [1 ,2 ]
Wang, Jingnan [1 ]
Li, Nan [3 ]
Zhang, Yue [3 ]
Cui, Jie [3 ]
Huo, Li [1 ]
Zhang, Hui [3 ,4 ]
机构
[1] Peking Union Med Coll Hosp, Chinese Acad Med Sci, Dept Nucl Med, State Key Lab Complex Severe & Rare Dis,Beijing Ke, Beijing 100730, Peoples R China
[2] Peking Union Med Coll Hosp, Chinese Acad Med Sci, Med Sci Res Ctr MRC, Beijing 100730, Peoples R China
[3] SinoUn Beijing Healthcare Technol Co Ltd, Beijing 100082, Peoples R China
[4] Tsinghua Univ, Dept Biomed Engn, Beijing 100084, Peoples R China
关键词
TOF-PET; MLAA; CT-OSEM; Quantitative evaluation; IMAGE; MLAA;
D O I
10.1186/s12880-023-00987-7
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
BackgroundThe maximum likelihood activity and attenuation (MLAA) reconstruction algorithm has been proposed to jointly estimate tracer activity and attenuation at the same time, and proven to be a promising solution to the CT attenuation correction (CT-AC) artifacts in PET images. This study aimed to perform a quantitative evaluation and clinical validation of the MLAA method.MethodsA uniform cylinder phantom filled with F-18-FDG solution was scanned to optimize the reconstruction parameters for the implemented MLAA algorithm. 67 patients who underwent whole-body F-18-FDG PET/CT scan were retrospectively recruited. PET images were reconstructed using MLAA and clinical standard OSEM algorithm with CT-AC (CT-OSEM). The mean and maximum standardized uptake values (SUVmean and SUVmax) in regions of interest (ROIs) of organs, high uptake lesions and areas affected by metal implants and respiration motion artifacts were quantitatively analyzed.ResultsIn quantitative analysis, SUVs in patient's organ ROIs between two methods showed R-2 ranging from 0.91 to 0.98 and k ranging from 0.90 to 1.06, and the average SUVmax and SUVmean differences between two methods were within 10% range, except for the lung ROI, which was 10.5% and 16.73% respectively. The average SUVmax and SUVmean differences of a total of 117 high uptake lesions were 7.25% and 7.10% respectively. 20 patients were identified to have apparent respiration motion artifacts in the liver in CT-OSEM images, and the SUVs differences between two methods measured at dome of the liver were significantly larger than measured at middle part of the liver. 10 regions with obvious metal artifacts were identified in CT-OSEM images and the average SUVmean and SUVmax differences in metal implants affected regions were reported to be 52.90% and 56.20% respectively.ConclusionsPET images reconstructed using MLAA are clinically acceptable in terms of image quality as well as quantification and it is a useful tool in clinical practice, especially when CT-AC may cause respiration motion and metal artifacts. Moreover, this study also provides technical reference and data support for the future iteration and development of PET reconstruction technology of SUV accurate quantification.
引用
收藏
页数:13
相关论文
共 50 条
  • [1] A quantitative clinical evaluation of simultaneous reconstruction of attenuation and activity in time-of-flight PET
    Haiqiong Zhang
    Jingnan Wang
    Nan Li
    Yue Zhang
    Jie Cui
    Li Huo
    Hui Zhang
    BMC Medical Imaging, 23
  • [2] Joint Reconstruction of Activity and Attenuation in Time-of-Flight PET: A Quantitative Analysis
    Rezaei, Ahmadreza
    Deroose, Christophe M.
    Vahle, Thomas
    Boada, Fernando
    Nuyts, Johan
    JOURNAL OF NUCLEAR MEDICINE, 2018, 59 (10) : 1630 - 1635
  • [3] Simultaneous emission and attenuation reconstruction in time-of-flight PET using a reference object
    Garcia-Perez, Pablo
    Espana, Samuel
    EJNMMI PHYSICS, 2020, 7 (01)
  • [4] Practical joint reconstruction of activity and attenuation with autonomous scaling for time-of-flight PET
    Li, Yusheng
    Matej, Samuel
    Karp, Joel S.
    PHYSICS IN MEDICINE AND BIOLOGY, 2020, 65 (23)
  • [5] An evaluation of image noise variance for time-of-flight PET
    Watson, Charles C.
    IEEE TRANSACTIONS ON NUCLEAR SCIENCE, 2007, 54 (05) : 1639 - 1647
  • [6] Benefit of time-of-flight in PET: Experimental and clinical results
    Karp, Joel S.
    Surti, Sulernan
    Daube-Witherspoon, Margaret E.
    Muehllehner, Gerd
    JOURNAL OF NUCLEAR MEDICINE, 2008, 49 (03) : 462 - 470
  • [7] Improving time resolution in time-of-flight PET
    Conti, Maurizio
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 2011, 648 : S194 - S198
  • [8] OPTIMIZATION OF DETECTORS FOR TIME-OF-FLIGHT PET
    Moszynski, Marek
    Szczesniak, Tomasz
    WORKSHOP ON TIMING DETECTORS: ELECTRONICS, MEDICAL AND PARTICLE PHYSICS APPLICATIONS, 2010, 4 (01): : 59 - 64
  • [9] Update on Time-of-Flight PET Imaging
    Surti, Suleman
    JOURNAL OF NUCLEAR MEDICINE, 2015, 56 (01) : 98 - 105
  • [10] DETECTION PERFORMANCE ANALYSIS FOR TIME-OF-FLIGHT PET
    Cao, Nannan
    Huesman, Ronald H.
    Moses, William W.
    Qi, Jinyi
    2009 IEEE INTERNATIONAL SYMPOSIUM ON BIOMEDICAL IMAGING: FROM NANO TO MACRO, VOLS 1 AND 2, 2009, : 402 - +