The MiniMed 780G automated insulin delivery system adapts to substantial changes in daily routine: Lessons from real world users during Ramadan

被引:9
作者
Al-Sofiani, Mohammed E. [1 ,2 ]
Petrovski, Goran [3 ,4 ]
Al Shaikh, Abdulrahman [5 ]
Alguwaihes, Abdullah [1 ,6 ]
Al Harbi, Mohammad [7 ]
Al Mohannadi, Dabia [8 ]
Adjene, Alero [9 ]
Alagha, Abdulmoeen [5 ]
Al Remeithi, Sareea [10 ]
Alamuddin, Naji [11 ,12 ]
Arrieta, Arcelia [13 ]
Castaneda, Javier [13 ]
Chaar, Wael [14 ]
van den Heuvel, Tim [13 ]
Cohen, Ohad [13 ,15 ]
机构
[1] King Saud Univ, Coll Med, Dept Internal Med, Riyadh, Saudi Arabia
[2] Johns Hopkins Univ, Div Endocrinol Diabet & Metab, Baltimore, MD USA
[3] Sidra Med, Div Endocrinol, Dept Pediat Med, Doha, Qatar
[4] Weill Cornell Med, Coll Med, Doha, Qatar
[5] King Abdulaziz Univ Hosp, Internal Med & Endocrinol, Jeddah, Saudi Arabia
[6] Dallah Hosp, Diabet Ctr, Riyadh, Saudi Arabia
[7] Minist Hlth, Dept Natl Diabet Ctr, Riyadh, Saudi Arabia
[8] Hamad Med Corp, Dept Med, Div Endocrinol & Diabet, Doha, Qatar
[9] Imperial Coll London, Dept Diabet & Endocrinol, Diabet Ctr, Abu Dhabi, U Arab Emirates
[10] Sheikh Khalifa Med City, Div Pediat Nephrol, Abu Dhabi, U Arab Emirates
[11] King Hamad Univ Hosp, Dept Internal Med, Manama, Bahrain
[12] Med Univ Bahrain, Royal Coll Surg Ireland, Dept Med, Manama, Bahrain
[13] Medtron Int Trading Sarl, Diabet Operat Unit, Tolochenaz, Switzerland
[14] Medtron Saudi Arabia, Diabet Operating Unit, Tolochenaz, Switzerland
[15] Medtron Int Trading Sarl, Diabet Operating Unit, Route Molliau 31, CH-1131 Tolochenaz, Switzerland
关键词
type; 1; diabetes; real-world evidence; insulin therapy; continuous glucose monitoring (CGM);
D O I
10.1111/dom.15389
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Aim: To report on the effectiveness and safety of the MiniMed 780G automated insulin delivery system in real-world users during the month of Ramadan.Materials and Methods: CareLink Personal data were extracted from MiniMed 780G system users from the Gulf region. Users were included if they had >= 10 days of sensor glucose data during the month of Ramadan 2022 as well as in the month before and after. For the main analysis, continuous glucose monitoring endpoints were aggregated per month and were reported by time of day (daytime: 05.31-18.00 h, and night-time). Additional analyses were performed to study the pace at which the algorithm adapts.Results: Glycaemic control was well kept in the 449 included users (mean sensor glucose = 152.6 +/- 18.7 mg/dl, glucose management indicator = 7.0 +/- 0.4%, time in range = 70.7 +/- 11.0%, time below 70 mg/dl = 2.3 +/- 2.3%). Albeit some metrics differed from the month before (p < .0001 for all), absolute differences were very small and considered clinically irrelevant. During Ramadan, there was no increased risk of hypoglycaemia during daytime (time below 70 mg/dl = 2.3 +/- 2.4%), time in range was highest during daytime (80.0 +/- 10.7%, night: 60.4 +/- 15.3%), while time above 180 mg/dl was highest during night-time (37.3 +/- 16.3%, day: 17.7 +/- 10.7%). The algorithm adapted immediately upon lifestyle change.Conclusion: The MiniMed 780G automated insulin delivery system is effective, safe and fast in adapting to the substantial changes that occur in the lifestyle of people with type 1 diabetes during Ramadan.
引用
收藏
页码:937 / 949
页数:13
相关论文
共 14 条
  • [1] 7. Diabetes Technology: Standards of Medical Care in Diabetes-2022
    不详
    [J]. DIABETES CARE, 2022, 45 : S97 - S112
  • [2] Comparison of MiniMed 780G system performance in users aged younger and older than 15 years: Evidence from 12 870 real-world users
    Arrieta, Arcelia
    Battelino, Tadej
    Scaramuzza, Andrea E.
    Da Silva, Julien
    Castaneda, Javier
    Cordero, Toni L.
    Shin, John
    Cohen, Ohad
    [J]. DIABETES OBESITY & METABOLISM, 2022, 24 (07) : 1370 - 1379
  • [3] Clinical Targets for Continuous Glucose Monitoring Data Interpretation: Recommendations From the International Consensus on Time in Range
    Battelino, Tadej
    Danne, Thomas
    Bergenstal, Richard M.
    Amiel, Stephanie A.
    Beck, Roy
    Biester, Torben
    Bosi, Emanuele
    Buckingham, Bruce A.
    Cefalu, William T.
    Close, Kelly L.
    Cobelli, Claudio
    Dassau, Eyal
    DeVries, J. Hans
    Donaghue, Kim C.
    Dovc, Klemen
    Doyle, Francis J.
    Garg, Satish
    Grunberger, George
    Heller, Simon
    Heinemann, Lutz
    Hirsch, Irl B.
    Hovorka, Roman
    Jia, Weiping
    Kordonouri, Olga
    Kovatchev, Boris
    Kowalski, Aaron
    Laffel, Lori
    Levine, Brian
    Mayorov, Alexander
    Mathieu, Chantal
    Murphy, Helen R.
    Nimri, Revital
    Norgaard, Kirsten
    Parkin, Christopher G.
    Renard, Eric
    Rodbard, David
    Saboo, Banshi
    Schatz, Desmond
    Stoner, Keaton
    Urakami, Tatsuiko
    Weinzimer, Stuart A.
    Phillip, Moshe
    [J]. DIABETES CARE, 2019, 42 (08) : 1593 - 1603
  • [4] Safety and Glycemic Outcomes During the MiniMed™ Advanced Hybrid Closed-Loop System Pivotal Trial in Adolescents and Adults with Type 1 Diabetes
    Carlson, Anders L.
    Sherr, Jennifer L.
    Shulman, Dorothy, I
    Garg, Satish K.
    Pop-Busui, Rodica
    Bode, Bruce W.
    Lilenquist, David R.
    Brazg, Ron L.
    Kaiserman, Kevin B.
    Kipnes, Mark S.
    Thrasher, James R.
    Reed, John H. Chip
    Slover, Robert H.
    Philis-Tsimikas, Athena
    Christiansen, Mark
    Grosman, Benyamin
    Roy, Anirban
    Vella, Melissa
    Jonkers, Richard A. M.
    Chen, Xiaoxiao
    Shin, John
    Cordero, Toni L.
    Lee, Scott W.
    Rhinehart, Andrew S.
    Vigersky, Robert A.
    [J]. DIABETES TECHNOLOGY & THERAPEUTICS, 2022, 24 (03) : 178 - 189
  • [5] Predictors of time in target glucose range in real-world users of the MiniMed 780G system
    Castaneda, Javier
    Mathieu, Chantal
    Aanstoot, Henk-Jan
    Arrieta, Arcelia
    Da Silva, Julien
    Shin, John
    Cohen, Ohad
    [J]. DIABETES OBESITY & METABOLISM, 2022, 24 (11) : 2212 - 2221
  • [6] Choudhary P, 2022, LANCET DIABETES ENDO, V10, P720, DOI [10.1016/S2213-8587(22)00212.1, 10.1016/S2213-8587(22)00212-1]
  • [7] Glycemic control during Ramadan fasting in adolescents and young adults with type 1 diabetes on MiniMed™ 780G advanced hybrid closed-loop system: A randomized controlled trial
    Elbarbary, Nancy Samir
    Ismail, Eman Abdel Rahman
    [J]. DIABETES RESEARCH AND CLINICAL PRACTICE, 2022, 191
  • [8] Diabetes and Ramadan: Practical guidelines 2021
    Hassanein, Mohamed
    Afandi, Bachar
    Ahmedani, Muhammad Yakoob
    Alamoudi, Reem Mohammad
    Alawadi, Fatheya
    Bajaj, Harpreet S.
    Basit, Abdul
    Bennakhi, Abdullah
    El Sayed, Adel A.
    Hamdy, Osama
    Hanif, Wasim
    Jabbar, Abdul
    Kleinebreil, Line
    Lessan, Nader
    Shaltout, Inass
    Bebakar, Wan Mohamad Wan
    Abdelgadir, Elamin
    Abdo, Sarah
    Al Ozairi, Ebaa
    Al Saleh, Yousef
    Alarouj, Monira
    Ali, Tomader
    Almadani, Abdulrazzaq Ali
    Assaad-Khalil, Samir Helmy
    Bashier, Alaaeldin Mohammed K.
    Beshyah, Salem Arifi
    Buyukbese, Mehmet Akif
    Chowdhury, Tahseen Ahmad
    Diop, Said Norou
    Elbarbary, Nancy Samir
    Elhadd, Tarik A.
    Eliana, Fatimah
    Faris, MoezAlIslam Ezzat
    Hafidh, Khadija
    Hussein, Zanariah
    Iraqi, Hinde
    Kaplan, Walid
    Khan, Tayyab S.
    Khunti, Kamlesh
    Maher, Salma
    Malek, Rachid
    Malik, Rayaz A.
    Mohamed, Mafauzy
    Mohamed, Mesbah Sayed Kamel
    Mohamed, Nazeer Ahmed
    Pathan, Sameer
    Rashid, Fauzia
    Sahay, Rakesh K.
    Salih, Bashir Taha
    Sandid, Mohamad A.
    [J]. DIABETES RESEARCH AND CLINICAL PRACTICE, 2022, 185
  • [9] The management of type 1 diabetes in adults. A consensus report by the American Diabetes Association (ADA) and the European Association for the Study of Diabetes (EASD)
    Holt, Richard I. G.
    DeVries, J. Hans
    Hess-Fischl, Amy
    Hirsch, Irl B.
    Kirkman, M. Sue
    Klupa, Tomasz
    Ludwig, Barbara
    Norgaard, Kirsten
    Pettus, Jeremy
    Renard, Eric
    Skyler, Jay S.
    Snoek, Frank J.
    Weinstock, Ruth S.
    Peters, Anne L.
    [J]. DIABETOLOGIA, 2021, 64 (12) : 2609 - 2652
  • [10] Glucose excursions and glycaemic control during Ramadan fasting in diabetic patients: Insights from continuous glucose monitoring (CGM)
    Lessan, N.
    Hannoun, Z.
    Hasan, H.
    Barakat, M. T.
    [J]. DIABETES & METABOLISM, 2015, 41 (01) : 28 - 36