Monte Carlo energy spectrum matching method for SiPM-based EJ254 plastic scintillator detector calibration

被引:1
作者
Li, JunYu [1 ]
Fan, Peng [2 ]
Zhu, ChengLin [2 ]
Wang, MengMeng [1 ]
Wei, ZhiYong [1 ]
Xia, Yan [2 ]
机构
[1] Nanjing Univ Aeronaut & Astronaut, Coll Astronaut, Nanjing 211106, Peoples R China
[2] Beijing Inst Spacecraft Syst Engn, Beijing 100094, Peoples R China
基金
北京市自然科学基金;
关键词
EJ254; Energy resolution; Energy calibration; Compton reference points; Backscattering coincidence experiment; GAMMA-RAY; SIMULATION; COUNTERS;
D O I
10.1016/j.nima.2022.167932
中图分类号
TH7 [仪器、仪表];
学科分类号
0804 ; 080401 ; 081102 ;
摘要
Accurate energy measurement is the precondition for the application of plastic scintillator-based spectrometers in space exploration missions, and appropriate energy calibration methods are very important for plastic scintillators. At the same time, the energy resolution is a key factor in evaluating the performance of spectrometers. In this paper, an energy calibration method that can be used for plastic scintillators is proposed, and the energy resolution calibration results were also obtained in the process. The key of the method is to focus on the accurate energy prediction of the reference points in the Compton Continuum by using the Monte Carlo energy spectrum matching method. In the calibration process, the experimental measurements and Monte Carlo simulations of 22Na and 137Cs were carried out, and the shapes of the obtained spectra were matched by a certain energy resolution model. By shape matching, the Monte Carlo simulations provided energies of reference points, and the experiments provided their corresponding channel numbers. Then the parameters of the energy calibration model were obtained by fitting with multiple reference points' paired data. Moreover, the backscattering experiments with 131I, 137Cs, and 232Th sources were executed to equivalently provide monoenergetic electrons to verify the energy calibration and energy resolution model parameters obtained for the EJ254 spectrometer. The accuracy was high in the energy range of 341 similar to 2381.6 keV, the maximum bias of the energy was -4.7 keV (@2381.6 keV), and the maximum bias of the energy resolution model was 4.7% (@341 keV).
引用
收藏
页数:11
相关论文
共 26 条
  • [11] Fast neutron flux spectrum aboard Mars Odyssey during cruise
    Feldman, WC
    Prettyman, TH
    Tokar, RL
    Boynton, WV
    Byrd, RC
    Fuller, KR
    Gasnault, O
    Longmire, JL
    Olsher, RH
    Storms, SA
    Thornton, GW
    [J]. JOURNAL OF GEOPHYSICAL RESEARCH-SPACE PHYSICS, 2002, 107 (A6)
  • [12] The MESSENGER gamma-ray and neutron spectrometer
    Goldsten, John O.
    Rhodes, Edgar A.
    Boynton, William V.
    Feldman, William C.
    Lawrence, David J.
    Trombka, Jacob I.
    Smith, David M.
    Evans, Larry G.
    White, Jack
    Madden, Norman W.
    Berg, Peter C.
    Murphy, Graham A.
    Gurnee, Reid S.
    Strohbehn, Kim
    Williams, Bruce D.
    Schaefer, Edward D.
    Monaco, Christopher A.
    Cork, Christopher P.
    Del Eckels, J.
    Miller, Wayne O.
    Burks, Morgan T.
    Hagler, Lisle B.
    DeTeresa, Steve J.
    Witte, Monika C.
    [J]. SPACE SCIENCE REVIEWS, 2007, 131 (1-4) : 339 - 391
  • [13] A simple method of energy calibration for thin plastic scintillator
    Hohara, S
    Saiho, F
    Tanaka, J
    Aoki, S
    Uozumi, Y
    Matoba, M
    [J]. IEEE TRANSACTIONS ON NUCLEAR SCIENCE, 2001, 48 (04) : 1172 - 1176
  • [14] A capture-gated neutron spectrometer for characterization of neutron sources and their shields
    Holm, Philip
    Perajarvi, Kari
    Ristkari, Samu
    Siiskonen, Teemu
    Toivonen, Harri
    [J]. NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 2014, 751 : 48 - 54
  • [15] Hubbell J.H., 2005, XCOM PHOTON CROSS SE
  • [16] Parametric optimization for energy calibration and gamma response function of plastic scintillation detectors using a genetic algorithm
    Jeon, Byoungil
    Kim, Jongyul
    Moon, Myungkook
    Cho, Gyuseong
    [J]. NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 2019, 930 : 8 - 14
  • [17] Iterative Monte Carlo simulation with the Compton kinematics-based GEB in a plastic scintillation detector
    Kim, Chankyu
    Kim, Yewon
    Moon, Myungkook
    Cho, Gyuseong
    [J]. NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 2015, 795 : 298 - 304
  • [18] Performance of 3D printed plastic scintillators for gamma-ray detection
    Kim, Dong-geon
    Lee, Sangmin
    Park, Junesic
    Son, Jaebum
    Kim, Tae Hoon
    Kim, Yong Hyun
    Pak, Kihong
    Kim, Yong Kyun
    [J]. NUCLEAR ENGINEERING AND TECHNOLOGY, 2020, 52 (12) : 2910 - 2917
  • [19] Kyratzis D., 2021, PLASTIC SCINTILLATOR
  • [20] Lawrence D.J., 2007, MESSENGER NEUTRON SP