Quantitative Label-free Determination of Thrombin Using a Chemically-modified M13 Virus-electrode Interface

被引:8
作者
Shin, Jae Hwan [1 ]
Yang, Hyo Jeong [1 ]
Kim, Ji Hong [1 ]
Yang, Jin Chul [2 ]
Park, Jinyoung [2 ]
Park, Jong Pil [1 ]
机构
[1] Chung Ang Univ, Dept Food Sci & Technol, Basic Res Lab, Anseong 17546, South Korea
[2] Kyungpook Natl Univ, Dept Polymer Sci & Engn, Daegu 41566, South Korea
基金
新加坡国家研究基金会;
关键词
thrombin; phage display; M13; phage; affinity peptide; electrochemical sensor; APTAMER; BACTERIOPHAGE; BLOOD;
D O I
10.1007/s12257-022-0361-9
中图分类号
Q81 [生物工程学(生物技术)]; Q93 [微生物学];
学科分类号
071005 ; 0836 ; 090102 ; 100705 ;
摘要
The use of affinity peptide displaying on the surface of M13 phage has emerged as a promising alternative to antibody-based detection methods owing to its diverse structure, mass production, easy purification, and genetic manipulation, as well as excellent stability. In this study, we aimed to identify highly selective and sensitive peptide-displayed M13 phage for thrombin detection using phage display technology. Phage display was conducted using two different phage libraries (linear and cyclic forms of peptides), which displayed affinity peptides capable of binding specifically to thrombin. Throughout the biopanning process, two phage clones that displayed both peptides (WGQSFWGYQHYS and CWKLLTPWC) were selected. After the characterization of their binding abilities using enzyme-linked immunosorbent assay, whole phage particles were covalently attached to a gold electrode using MUA-EDC/NHS coupling chemistry. The thrombin detection mechanism was based on signal inhibition, and the results revealed that the specific interactions between the phage-tethered gold electrode and thrombin are critical factors affecting the decrease in the peak current of the sensor. In addition, under optimal conditions, the fabricated phage-based electrochemical sensors were capable of highly sensitive and specific thrombin detection with a good binding affinity (K-d = 17 nM for 12mer 3-17 and 14 nM for C7C 3-5) and limit of detection (4 nM for 12mer 3-17 and 10 nM for C7C 3-5), resulting in good reproducibility, even in artificial human plasma samples. This study may provide an alternative and more efficient method of detecting thrombin with desirable sensitivity, selectivity, and feasibility for the diagnosis and prognosis of coagulation disorder-related diseases.
引用
收藏
页码:235 / 245
页数:11
相关论文
共 30 条
[1]   Fast amperometric immunoplatform for ovomucoid traces determination in fresh and baked foods [J].
Benede, S. ;
Ruiz-Valdepenas Montiel, V. ;
Povedano, E. ;
Villalba, M. ;
Mata, L. ;
Galan-Malo, P. ;
Torrente-Rodriguez, R. M. ;
Vargas, E. ;
Reviejo, A. J. ;
Campuzano, S. ;
Pingarron, J. M. .
SENSORS AND ACTUATORS B-CHEMICAL, 2018, 265 :421-428
[2]   Analytical performances of aptamer-based sensing for thrombin detection [J].
Bini, Alessandra ;
Minunni, Maria ;
Tombelli, Sara ;
Centi, Sonia ;
Mascini, Marco .
ANALYTICAL CHEMISTRY, 2007, 79 (07) :3016-3019
[3]   Determination of the survival of bacteriophage M13 from chemical and physical challenges to assist in its sustainable bioprocessing [J].
Branston, Steven D. ;
Stanley, Emma C. ;
Ward, John M. ;
Keshavarz-Moore, Eli .
BIOTECHNOLOGY AND BIOPROCESS ENGINEERING, 2013, 18 (03) :560-566
[4]   Different approaches for the detection of thrombin by an electrochemical aptamer-based assay coupled to magnetic beads [J].
Centi, S. ;
Messina, G. ;
Tombelli, S. ;
Palchetti, I. ;
Mascini, M. .
BIOSENSORS & BIOELECTRONICS, 2008, 23 (11) :1602-1609
[5]   Aptamer-Based SERRS Sensor for Thrombin Detection [J].
Cho, Hansang ;
Baker, Brian R. ;
Wachsmann-Hogiu, Sebastian ;
Pagba, Cynthia V. ;
Laurence, Ted A. ;
Lane, Stephen M. ;
Lee, Luke P. ;
Tok, Jeffrey B. -H. .
NANO LETTERS, 2008, 8 (12) :4386-4390
[6]   Chemical modulation of M13 bacteriophage and its functional opportunities for nanomedicine [J].
Chung, Woo-Jae ;
Lee, Doe-Young ;
Yoo, So Young .
INTERNATIONAL JOURNAL OF NANOMEDICINE, 2014, 9 :5825-5836
[7]   A novel strategy for sensitive detection of thrombin via subtly integrated polypeptide substrate and aggregation-induced emission fluorophores in carotid artery thrombosis [J].
Du, Kunze ;
Wang, Bing ;
Chen, Shujing ;
Cui, Yan ;
Wang, Shuangqi ;
Liang, Chunxiao ;
Shang, Ye ;
Wang, Chenhong ;
Hou, Shixin ;
Li, Jin ;
Yu, Xie-an ;
Chang, Yanxu .
SENSORS AND ACTUATORS B-CHEMICAL, 2022, 370
[8]   A simple nonenzymatic glucose sensor based on coconut shell charcoal powder-coated nickel foil electrode [J].
Edakkaparamban, Shuaib ;
Parasseri, Muhammed Shafi ;
Yogesh, Gaurav Kumar ;
Arumugam, Chandra Bose ;
Dillibabu, Sastikumar .
CARBON LETTERS, 2021, 31 (04) :729-735
[9]   Amplified Electrochemical Biosensing of Thrombin Activity by RAFT Polymerization [J].
Hu, Qiong ;
Bao, Yu ;
Gan, Shiyu ;
Zhang, Yuwei ;
Han, Dongxue ;
Niu, Li .
ANALYTICAL CHEMISTRY, 2020, 92 (04) :3470-3476
[10]   Concentration-dependent emission of nitrogen-doped carbon dots and its use in hazardous metal-ion detection [J].
Jana, Jayasmita ;
Hur, Seung Hyun .
CARBON LETTERS, 2021, 31 (03) :523-536