Bionic reconstruction of tension trabeculae in short-stem hip arthroplasty: a finite element analysis

被引:3
|
作者
Ding, Zhentao [1 ,2 ,3 ]
Wang, Jun [4 ,5 ]
Wang, Yanhua [1 ,2 ,3 ]
Zhang, Xiaomeng [1 ,2 ,3 ]
Huan, Yong [4 ,5 ]
Zhang, Dianying [1 ,2 ,3 ]
机构
[1] Peking Univ Peoples Hosp, Dept Orthoped & Trauma, Beijing 100044, Peoples R China
[2] Peking Univ Peoples Hosp, Natl Ctr Trauma Med, Beijing 100044, Peoples R China
[3] Peking Univ, Key Lab Trauma & Neural Regenerat, Minist Educ, Beijing 100044, Peoples R China
[4] Chinese Acad Sci, Inst Mech, State Key Lab Nonlinear Mech LNM, Beijing 100190, Peoples R China
[5] Univ Chinese Acad Sci, Sch Engn Sci, Beijing 100049, Peoples R China
关键词
Short-stem hip arthroplasty; Stress shielding; Hip biomechanics; Bionic reconstruction; Tension screw; Finite element analysis; FOLLOW-UP; MUSCLE FORCES; BONE LOSS; IMPLANT; DENSITY; BIOMECHANICS; SENSITIVITY; FIXATION; FEMUR; LOAD;
D O I
10.1186/s12891-023-06205-3
中图分类号
R826.8 [整形外科学]; R782.2 [口腔颌面部整形外科学]; R726.2 [小儿整形外科学]; R62 [整形外科学(修复外科学)];
学科分类号
摘要
BackgroundShort-stem hip arthroplasty (SHA) is characterized by metaphyseal load transfer that effectively preserves the bone stock, but still suffers from stress shielding in the proximal femur. We designed a tension screw to mimic tension trabeculae in the new bionic collum femoris preserving (BCFP) short stem for bionic reconstruction, aiming to restore the biomechanics of hip joint.MethodsNative femur finite element model was constructed to investigate the biomechanics of hip joint based on computed tomography (CT) data. The maximum absolute principal stress/strain cloud chart allowed the direction of stress/strain to be assessed. Six BCFP models with different screw angles (5 degrees, 10 degrees, 15 degrees, 20 degrees, 25 degrees, and 30 degrees) and the Corail model were created. The stress/strain distribution and overall stiffness were compared between each of the BCFP and Corail implanted models.ResultsThe native model visualized the transfer pathways of tensile and compressive stress. The BCFP stems showed significantly higher stress and strain distribution in the greater trochanteric region compared to conventional total hip arthroplasty (THA). In particular, the BCFP-5 degrees stem demonstrated the highest average strain in both medial and lateral regions and the overall stiffness was closest to the intact femur.ConclusionsStress transfer pathways of trabecular architecture provide biomechanical insight that serves as the basis for bionic reconstruction. The tension screw improves load transfer pattern in the proximal femur and prevents stress reduction in the greater trochanteric region. The BCFP-5 degrees stem minimizes the stress shielding effect and presents a more bionic mechanical performance.
引用
收藏
页数:11
相关论文
共 50 条
  • [31] Effect of stem position and length on bone-stem constructs after cementless hip arthroplasty A FINITE ELEMENT ANALYSIS
    Kwak, D-K
    Bang, S-H
    Lee, S-J
    Park, J-H
    Yoo, J-H
    BONE & JOINT RESEARCH, 2021, 10 (04): : 250 - 258
  • [32] Patient-specific three-dimensional evaluation of interface micromotion in two different short stem designs in cementless total hip arthroplasty: a finite element analysis
    Kanaizumi, Arata
    Suzuki, Daisuke
    Nagoya, Satoshi
    Teramoto, Atsushi
    Yamashita, Toshihiko
    JOURNAL OF ORTHOPAEDIC SURGERY AND RESEARCH, 2022, 17 (01)
  • [33] Calcar-guided short-stem total hip arthroplasty: Will it be the future standard? Review and perspectives
    Kutzner, Karl Philipp
    WORLD JOURNAL OF ORTHOPEDICS, 2021, 12 (08): : 534 - 547
  • [34] Development and Finite Element (FE) analysis of a novel short hip stem concept
    Jahnke, Alexander
    Harz, Torben
    Ulloa, Carlos Alfonso Fonseca
    Ishaque, Bernd Alexander
    Rickert, Markus
    JOURNAL OF ORTHOPAEDICS, 2023, 46 : 117 - 123
  • [35] Risk Factors and Outcomes Associated with Intraoperative Fractures during Short-Stem Total Hip Arthroplasty for Osteonecrosis of the Femoral Head
    Malhotra, Rajesh
    Gupta, Saurabh
    Gupta, Vivek
    Manhas, Vikrant
    CLINICS IN ORTHOPEDIC SURGERY, 2022, 14 (01) : 41 - 47
  • [36] Finite Element Analysis of Bone Remodeling after Hip Resurfacing Arthroplasty
    Behrens, Bernd-Arno
    Nolte, Ingo
    Wefstaedt, Patrick
    Stukenborg-Colsman, Christina
    Bouguecha, Anas
    4TH EUROPEAN CONFERENCE OF THE INTERNATIONAL FEDERATION FOR MEDICAL AND BIOLOGICAL ENGINEERING, 2009, 22 (1-3): : 2288 - 2291
  • [37] Finite element analysis of the mechanical behavior of the different angle hip femoral stem
    Guvercin, Yilmaz
    Yaylaci, Murat
    Olmez, Hasan
    Yaylaci, Ecren Uzun
    Ozdemir, Mehmet Emin
    Dizdar, Ayberk
    BIOMATERIALS AND BIOMECHANICS IN BIOENGINEERING, 2022, 6 (01): : 29 - 46
  • [38] Analysis of Postoperative Complication and Revision Rates and Mid- to Long-Term Implant Survival in Primary Short-Stem Total Hip Arthroplasty
    Stauss, Ricarda
    Becker, Nils T.
    Savov, Peter
    Ettinger, Max
    Seeber, Gesine H.
    JOURNAL OF CLINICAL MEDICINE, 2024, 13 (13)
  • [39] Primary and long-term stability of a short-stem hip implant
    Dabirrahmani, D.
    Hoge, M.
    Kahan, L.
    Gillies, M.
    PROCEEDINGS OF THE INSTITUTION OF MECHANICAL ENGINEERS PART H-JOURNAL OF ENGINEERING IN MEDICINE, 2010, 224 (H9) : 1109 - 1119
  • [40] Finite element analysis of hip stem designs
    Bennett, David
    Goswami, Tarun
    MATERIALS & DESIGN, 2008, 29 (01) : 45 - 60