Bionic reconstruction of tension trabeculae in short-stem hip arthroplasty: a finite element analysis

被引:3
|
作者
Ding, Zhentao [1 ,2 ,3 ]
Wang, Jun [4 ,5 ]
Wang, Yanhua [1 ,2 ,3 ]
Zhang, Xiaomeng [1 ,2 ,3 ]
Huan, Yong [4 ,5 ]
Zhang, Dianying [1 ,2 ,3 ]
机构
[1] Peking Univ Peoples Hosp, Dept Orthoped & Trauma, Beijing 100044, Peoples R China
[2] Peking Univ Peoples Hosp, Natl Ctr Trauma Med, Beijing 100044, Peoples R China
[3] Peking Univ, Key Lab Trauma & Neural Regenerat, Minist Educ, Beijing 100044, Peoples R China
[4] Chinese Acad Sci, Inst Mech, State Key Lab Nonlinear Mech LNM, Beijing 100190, Peoples R China
[5] Univ Chinese Acad Sci, Sch Engn Sci, Beijing 100049, Peoples R China
关键词
Short-stem hip arthroplasty; Stress shielding; Hip biomechanics; Bionic reconstruction; Tension screw; Finite element analysis; FOLLOW-UP; MUSCLE FORCES; BONE LOSS; IMPLANT; DENSITY; BIOMECHANICS; SENSITIVITY; FIXATION; FEMUR; LOAD;
D O I
10.1186/s12891-023-06205-3
中图分类号
R826.8 [整形外科学]; R782.2 [口腔颌面部整形外科学]; R726.2 [小儿整形外科学]; R62 [整形外科学(修复外科学)];
学科分类号
摘要
BackgroundShort-stem hip arthroplasty (SHA) is characterized by metaphyseal load transfer that effectively preserves the bone stock, but still suffers from stress shielding in the proximal femur. We designed a tension screw to mimic tension trabeculae in the new bionic collum femoris preserving (BCFP) short stem for bionic reconstruction, aiming to restore the biomechanics of hip joint.MethodsNative femur finite element model was constructed to investigate the biomechanics of hip joint based on computed tomography (CT) data. The maximum absolute principal stress/strain cloud chart allowed the direction of stress/strain to be assessed. Six BCFP models with different screw angles (5 degrees, 10 degrees, 15 degrees, 20 degrees, 25 degrees, and 30 degrees) and the Corail model were created. The stress/strain distribution and overall stiffness were compared between each of the BCFP and Corail implanted models.ResultsThe native model visualized the transfer pathways of tensile and compressive stress. The BCFP stems showed significantly higher stress and strain distribution in the greater trochanteric region compared to conventional total hip arthroplasty (THA). In particular, the BCFP-5 degrees stem demonstrated the highest average strain in both medial and lateral regions and the overall stiffness was closest to the intact femur.ConclusionsStress transfer pathways of trabecular architecture provide biomechanical insight that serves as the basis for bionic reconstruction. The tension screw improves load transfer pattern in the proximal femur and prevents stress reduction in the greater trochanteric region. The BCFP-5 degrees stem minimizes the stress shielding effect and presents a more bionic mechanical performance.
引用
收藏
页数:11
相关论文
共 50 条
  • [21] Periprosthetic bone remodelling of short-stem total hip arthroplasty: a systematic review
    Shuang G. Yan
    Patrick Weber
    Arnd Steinbrück
    Xingyi Hua
    Volkmar Jansson
    Florian Schmidutz
    International Orthopaedics, 2018, 42 : 2077 - 2086
  • [22] Biomechanical Properties of Bionic Collum Femoris Preserving Hip Prosthesis: A Finite Element Analysis
    Zhang, Xiaomeng
    Wang, Yanhua
    Zhang, Lijia
    Yu, Kai
    Ding, Zhentao
    Zhang, Yichong
    Chen, Xiaofeng
    Xiong, Chen
    Ji, Yun
    Zhang, Dianying
    Ma, Xinlong
    ORTHOPAEDIC SURGERY, 2023, 15 (04) : 1126 - 1135
  • [23] Short-stem prostheses in primary total hip arthroplasty: A meta-analysis of randomized controlled trials
    Huo, Shao-Chuan
    Wang, Fan
    Dong, Lu-Jue
    Wei, Wei
    Zeng, Jing-Qi
    Huang, Hong-Xing
    Han, Qing-Min
    Duan, Rui-Qi
    MEDICINE, 2016, 95 (43)
  • [24] Metaphyseal anchoring short stem hip arthroplasty provides a more physiological load transfer: a comparative finite element analysis study
    Shuang G. Yan
    Yan Chevalier
    Fanxiao Liu
    Xingyi Hua
    Anna Schreiner
    Volkmar Jansson
    Florian Schmidutz
    Journal of Orthopaedic Surgery and Research, 15
  • [25] Metaphyseal anchoring short stem hip arthroplasty provides a more physiological load transfer: a comparative finite element analysis study
    Yan, Shuang G.
    Chevalier, Yan
    Liu, Fanxiao
    Hua, Xingyi
    Schreiner, Anna
    Jansson, Volkmar
    Schmidutz, Florian
    JOURNAL OF ORTHOPAEDIC SURGERY AND RESEARCH, 2020, 15 (01)
  • [26] Finite Element Analysis of porously punched prosthetic short stem virtually designed for simulative uncemented Hip Arthroplasty
    Matthew Jian-Qiao Peng
    Hai-Yan Chen
    Yong Hu
    XiangYang Ju
    Bo Bai
    BMC Musculoskeletal Disorders, 18
  • [27] Bone preserving level of osteotomy in short-stem total hip arthroplasty does not influence stress shielding dimensions – a comparing finite elements analysis
    Rene Burchard
    Sabrina Braas
    Christian Soost
    Jan Adriaan Graw
    Jan Schmitt
    BMC Musculoskeletal Disorders, 18
  • [28] Are short-stem prostheses superior to conventional stem prostheses in primary total hip arthroplasty? A systematic review and meta-analysis of randomised controlled trials
    Liang, Hao-Dong
    Yang, Wei-Yi
    Pan, Jian-Ke
    Huang, He-Tao
    Luo, Ming-Hui
    Zeng, Ling-Feng
    Liu, Jun
    BMJ OPEN, 2018, 8 (09):
  • [29] Short-stem uncemented primary reverse shoulder arthroplasty
    Giuseffi, S. A.
    Streubel, P.
    Sperling, J.
    Sanchez-Sotelo, J.
    BONE & JOINT JOURNAL, 2014, 96B (04) : 526 - 529
  • [30] Anatomic Reconstruction of Hip Joint Biomechanics: Conventional vs. Short-Stem Prosthesis
    Ries, C.
    Schopf, W.
    Dietrich, F.
    Franke, S.
    Jakubowitz, E.
    Sobau, C.
    Heisel, C.
    ZEITSCHRIFT FUR ORTHOPADIE UND UNFALLCHIRURGIE, 2015, 153 (01): : 46 - 50