An isotope dilution-liquid chromatography-tandem mass spectrometry (ID-LC-MS/MS)-based candidate reference measurement procedure (RMP) for the quantification of phenobarbital in human serum and plasma

被引:1
|
作者
Schierscher, Tobias [1 ]
Salzmann, Linda [1 ]
Singh, Neeraj [2 ]
Bachmann, Martina [2 ]
Kobel, Anja [1 ]
Wild, Janik [1 ]
Bauland, Friederike [3 ]
Geistanger, Andrea [2 ]
Risch, Lorenz [1 ]
Geletneky, Christian [2 ]
Seger, Christoph [1 ]
Taibon, Judith [2 ,4 ]
机构
[1] Dr Risch Ostschweiz AG, Buchs, Switzerland
[2] Roche Diagnost GmbH, Penzberg, Germany
[3] Chrestos Concept GmbH & Co KG, Essen, Germany
[4] Roche Diagnost GmbH, Nonnenwald 2, D-82377 Penzberg, Germany
关键词
phenobarbital; ID-LC-MS/MS; reference measurement procedure; SI units; traceability; ANTIEPILEPTIC DRUGS; SPECIFICATIONS; PERFORMANCE; METABOLITES; IONIZATION; EPILEPSY; EFFICACY; POSITION; BLOOD; MS;
D O I
10.1515/cclm-2023-1104
中图分类号
R446 [实验室诊断]; R-33 [实验医学、医学实验];
学科分类号
1001 ;
摘要
Objectives: Phenobarbital serves as an antiepileptic drug (AED) and finds application in the treatment of epilepsy either as monotherapy or adjunctive therapy. This drug exhibits various pharmacodynamic properties that account for its beneficial effects as well as potential side effects. Accurate measurement of its concentration is critical for optimizing AED therapy through appropriate dose adjustments. Therefore, our objective was to develop and validate a new reference measurement procedure (RMP) for the accurate quantification of phenobarbital levels in human serum and plasma. Methods: A sample preparation protocol based on protein precipitation followed by a high dilution step was established in combination with a liquid chromatography-tandem mass spectrometry (LC-MS/MS) method using a C8 column to separate target analytes from known and unknown interferences. Assay validation and determination of measurement uncertainty were performed based on current guidelines. Selectivity and Specificity were assessed using spiked serum and plasma samples; to investigate possible matrix effects (MEs) a post-column infusion experiment and a comparison of standard line slopes was performed. Precision and accuracy were determined within a multiday precision experiment. Results: The RMP was shown to be highly selective and specific, with no evidence of matrix interferences. It can be used to quantify phenobarbital in the range of 1.92 to 72.0 mu g/mL. Intermediate precision was less than 3.2 %, and repeatability coefficient of variation (CV) ranged from 1.3 to 2.0 % across all concentration levels. The relative mean bias ranged from -3.0 to -0.7 % for native serum levels, and from -2.8 to 0.8 % for Li-heparin plasma levels. The measurement uncertainties (k=1) for single measurements and target value assignment were 1.9 to 3.3 % and 0.9 to 1.6 %, respectively. Conclusions: A novel LC-MS/MS-based candidate RMP for the quantification of phenobarbital in human serum and plasma is presented which can be used for the standardization of routine assays and the evaluation of clinically relevant samples.
引用
收藏
页码:1314 / 1326
页数:13
相关论文
共 50 条
  • [21] SERUM CONCENTRATION OF TESTOSTERONE MEASURED BY ISOTOPE DILUTION-LIQUID CHROMATOGRAPHY-TANDEM MASS SPECTROMETRY (ID-LC-MS/MS) IN MEN AFTER BILATERAL ORCHIECTOMY OR LUTEINIZING HORMONE RELEASING HORMONE (LHRH) AGONIST THERAPY
    van der Sluis, Tim
    Bui, Hong
    Heijboer, Annemieke
    Meuleman, Eric
    van Moorselaar, Jeroen
    Blankenstein, Marinus
    van Adrichem, Nick
    de Ronde, Willem
    Vis, Andre
    JOURNAL OF UROLOGY, 2011, 185 (04): : E289 - E289
  • [22] Isotope-dilution-LC-MS/MS candidate reference measurement procedure for cefepime in human serum
    Schaeffler, Judith
    Vogeser, Michael
    Habler, Katharina
    JOURNAL OF MASS SPECTROMETRY AND ADVANCES IN THE CLINICAL LAB, 2024, 33 : 43 - 48
  • [23] Quantification of cyclizine and norcyclizine in human plasma by liquid chromatography-tandem mass spectrometry (LC-MS/MS)
    Jensen, Berit Packert
    Vella-Brincat, Jane Winifred Ann
    Begg, Evan James
    JOURNAL OF CHROMATOGRAPHY B-ANALYTICAL TECHNOLOGIES IN THE BIOMEDICAL AND LIFE SCIENCES, 2011, 879 (9-10): : 605 - 609
  • [24] Measurement of dehydroepiandrosterone sulphate (DHEAS): A comparison of Isotope-Dilution Liquid Chromatography Tandem Mass Spectrometry (ID-LC-MS/MS) and seven currently available immunoassays
    Buttler, Rahel M.
    Kruit, Adrian
    Blankenstein, Marinus A.
    Heijboer, Annemieke C.
    CLINICA CHIMICA ACTA, 2013, 424 : 22 - 26
  • [25] Quantification of free serum cortisol based on equilibrium dialysis and isotope dilution-liquid chromatography-tandem mass spectrometry
    Kirchhoff, Fabian
    Briegel, Josef
    Vogeser, Michael
    CLINICAL BIOCHEMISTRY, 2011, 44 (10-11) : 894 - 899
  • [26] Reference values for salivary testosterone in adolescent boys and girls determined using Isotope-Dilution Liquid-Chromatography Tandem Mass Spectrometry (ID-LC-MS/MS)
    Buttler, Rahel M.
    Peper, Jiska S.
    Crone, Eveline A.
    Lentjes, Eef G. W.
    Blankenstein, Marinus A.
    Heijboer, Annemieke C.
    CLINICA CHIMICA ACTA, 2016, 456 : 15 - 18
  • [27] Quantification of mycophenolic acid in plasma by isotope dilution liquid chromatography-tandem mass spectrometry candidate reference method
    Lin, Jing
    Shen, Min
    Yu, Ting
    Wang, Huimin
    Pan, Jingjue
    Huang, Gaipeng
    Li, Quanle
    ANALYTICAL AND BIOANALYTICAL CHEMISTRY, 2025, 417 (08) : 1607 - 1617
  • [28] Determination of serum creatinine by liquid chromatography isotope dilution tandem mass spectrometry (LC-IDMS/MS): A candidate reference method
    Rasoul, Alikhani-Koupaei
    Mehrdad, Yazdanpanah
    Eleftherios, Diamandis
    Barry, Hoffman
    Khosrow, Adeli
    Jeffrey, Tong
    CLINICAL BIOCHEMISTRY, 2008, 41 (14-15) : 1273 - 1273
  • [29] Quantification of bone markers by liquid chromatography-tandem mass spectrometry (LC/MS/MS).
    Ospina, MP
    Vesper, H
    Audain, C
    Woolfitt, R
    Barr, JR
    Myers, G
    CLINICAL CHEMISTRY, 2003, 49 (06) : A127 - A128
  • [30] Description and validation of an equilibrium dialysis ID-LC-MS/MS candidate reference measurement procedure for free thyroxine in human serum
    Jansen, Heleen I.
    van der Steen, Rob
    Brandt, Andre
    Olthaar, Andre J.
    Vesper, Hubert W.
    Shimizu, Eri
    Heijboer, Annemieke C.
    Van Uytfanghe, Katleen
    van Herwaarden, Antonius E.
    CLINICAL CHEMISTRY AND LABORATORY MEDICINE, 2023, 61 (09) : 1605 - 1611