A Quasi-Passive Robotic Ankle Foot Orthosis With Speed-Adaptive Stiffness

被引:6
|
作者
Hopkins, Samuel [1 ]
Bowersock, Collin [1 ]
Rouse, Elliott J. [2 ,3 ]
Lerner, Zachary F. [1 ,4 ]
机构
[1] No Arizona Univ, Mech Engn Dept, Flagstaff, AZ 86011 USA
[2] Univ Michigan, Dept Robot, Ann Arbor, MI 48109 USA
[3] Univ Michigan, Dept Mech Engn, Ann Arbor, MI 48109 USA
[4] Univ Arizona, Coll Med Phoenix, Dept Orthoped, Phoenix, AZ 85004 USA
关键词
Biologically-inspired robots; compliance and impedance control; compliant joints and mechanism; human-robot interaction; wearable robotics; WALKING; PERFORMANCE; ACTUATOR;
D O I
10.1109/LRA.2024.3349829
中图分类号
TP24 [机器人技术];
学科分类号
080202 ; 1405 ;
摘要
Ankle foot orthoses (AFOs) are one of the most prescribed mobility devices for individuals with walking disability from conditions like cerebral palsy (CP) and stroke. Current AFO designs offer a fixed stiffness during walking, functioning optimally at only a single speed. The primary goal of this study was to develop and validate a quasi-passive robotic AFO that automatically adjusted stiffness to a user's walking speed. We designed a leaf spring AFO with an adjustable pivot point actuated by a compact linear servo motor. We developed a walking speed estimator using onboard sensors to automatically adjust the pivot point location, and therefore device stiffness. First, we characterized stiffness range, adjustment response time, and battery life during walking. Next, we performed clinical device validation testing in five individuals with CP during stand-to-run acceleration bouts and at constant walking speeds. The AFO exhibited a stiffness range of 60 to 250 Nm/rad during normal walking and up to 300-400 Nm/rad under certain conditions (e.g., running) for the CP participants. The device was able to adjust stiffness by similar to 200 Nm/rad during swing phase in similar to 0.25 seconds. Battery life approached 6000 steps. The on-board controller accurately predicted relative changes in walking speed for the five participants with CP (R-2 = 0.92 +/- 0.04), demonstrating the ability to automatically increase device stiffness with ambulation speed. This study advances the state-of-the-art for quasi-passive AFOs that can function optimally at different ambulation speeds.
引用
收藏
页码:1740 / 1747
页数:8
相关论文
共 50 条
  • [1] Design of a Quasi-Passive Ankle-Foot Orthosis with Customizable, Variable Stiffness
    Van Crey, Nikko
    Cavallin, Marcos
    Shepherd, Max
    Rouse, Elliott J.
    2023 INTERNATIONAL CONFERENCE ON REHABILITATION ROBOTICS, ICORR, 2023,
  • [2] A Quasi-Passive Compliant Stance Control Knee-Ankle-Foot Orthosis
    Shamaei, Kamran
    Napolitano, Paul C.
    Dollar, Aaron M.
    2013 IEEE 13TH INTERNATIONAL CONFERENCE ON REHABILITATION ROBOTICS (ICORR), 2013,
  • [3] Design of a quasi-passive 3 DOFs ankle-foot wearable rehabilitation orthosis
    Zhang, Chao
    Zhu, Yanhe
    Fan, Jizhuang
    Zhao, Jie
    Yu, Hongying
    BIO-MEDICAL MATERIALS AND ENGINEERING, 2015, 26 : S647 - S654
  • [4] The VSPA Foot: A Quasi-Passive Ankle-Foot Prosthesis With Continuously Variable Stiffness
    Shepherd, Max K.
    Rouse, Elliott J.
    IEEE TRANSACTIONS ON NEURAL SYSTEMS AND REHABILITATION ENGINEERING, 2017, 25 (12) : 2375 - 2386
  • [5] Design and Functional Evaluation of a Quasi-Passive Compliant Stance Control Knee-Ankle-Foot Orthosis
    Shamaei, Kamran
    Napolitano, Paul C.
    Dollar, Aaron M.
    IEEE TRANSACTIONS ON NEURAL SYSTEMS AND REHABILITATION ENGINEERING, 2014, 22 (02) : 258 - 268
  • [6] Passive ankle joint stiffness compensation by a novel Ankle-Foot-Orthosis
    Rodriguez, Karen
    de Groot, Jurriaan
    Baas, Frank
    Stijntjes, Marjon
    van der Helm, Frans
    van der Kooij, Herman
    Mugge, Winfred
    2018 7TH IEEE INTERNATIONAL CONFERENCE ON BIOMEDICAL ROBOTICS AND BIOMECHATRONICS (BIOROB2018), 2018, : 517 - 522
  • [7] Design and Characterization of a Quasi-Passive Pneumatic Foot-Ankle Prosthesis
    Lee, Jeffrey D.
    Mooney, Luke M.
    Rouse, Elliott J.
    IEEE TRANSACTIONS ON NEURAL SYSTEMS AND REHABILITATION ENGINEERING, 2017, 25 (07) : 823 - 831
  • [8] The VSPA Foot: A Quasi-Passive Ankle-Foot Prosthesis With Continuously Variable Stiffness (vol 25, pg 2375, 2017)
    Shepherd, Max K.
    Rouse, Elliott J.
    IEEE TRANSACTIONS ON NEURAL SYSTEMS AND REHABILITATION ENGINEERING, 2018, 26 (03) : 716 - 716
  • [9] Design and Characterization of a Biologically Inspired Quasi-Passive Prosthetic Ankle-Foot
    Mooney, Luke M.
    Lai, Cara H.
    Rouse, Elliott J.
    2014 36TH ANNUAL INTERNATIONAL CONFERENCE OF THE IEEE ENGINEERING IN MEDICINE AND BIOLOGY SOCIETY (EMBC), 2014, : 1611 - 1617
  • [10] A Data Driven Approach for Predicting Preferred Ankle Stiffness of a Quasi-Passive Prosthesis
    Shetty, Varun S.
    Lee, Ung Hee
    Ingraham, Kimberly A.
    Rouse, Elliott J.
    IEEE ROBOTICS AND AUTOMATION LETTERS, 2022, 7 (02) : 3467 - 3474