Quantitative comparison of 2D and 3D monitoring dimensions in fish behavior analysis

被引:3
|
作者
Lin, Kai [1 ,2 ,5 ,6 ]
Zhang, Shiyu [3 ,7 ]
Hu, Junjie [1 ,2 ,3 ]
Lv, Xingdong [1 ,2 ,3 ]
Li, Hongsong [4 ]
机构
[1] Beijing Acad Agr & Forestry Sci, Fisheries Sci Inst, Beijing, Peoples R China
[2] Beijing Key Lab Fishery Biotechnol, Beijing, Peoples R China
[3] Beijing Informat Sci & Technol Univ, Sch Instrument Sci & Opto Elect Engn, Beijing, Peoples R China
[4] Beijing Inst Technol, Sch Comp Sci & Technol, Beijing, Peoples R China
[5] Beijing Acad Agr & Forestry Sci, Fisheries Sci Inst, Beijing 100068, Peoples R China
[6] Beijing Key Lab Fishery Biotechnol, Beijing 100068, Peoples R China
[7] Beijing Informat Sci & Technol Univ, Sch Instrument Sci & Opto Elect Engn, Beijing 100192, Peoples R China
基金
北京市自然科学基金;
关键词
fish behavior; fractal dimension; monitoring dimensions; swimming distance; U-turns; FRACTAL DIMENSION; VIDEO TRACKING; VISION SYSTEM; QUANTIFICATION; RESPONSES;
D O I
10.1111/jfb.15633
中图分类号
S9 [水产、渔业];
学科分类号
0908 ;
摘要
To improve the accuracy and efficiency of fish behavior assessment, this paper focuses on quantitatively exploring the variations and relationships between different monitoring dimensions. A systematic comparison was conducted between 3D and 2D behavioral factors using an infrared tracing system, during both day and night. Significant differences in swimming distance were observed among the different monitoring methods, as determined by two-way ANOVA and Tukey's test. A correction was applied to account for the disparities observed in 2D swimming distance, ensuring accurate measurements. These findings present a cost-effective and efficient approach for obtaining precise 3D distance data. Additionally, a kinematic factor called the "number of U-turns" was proposed to provide a more intuitive characterization of directional changes in fish swimming. Significant differences were observed between 2D and 3D data, with higher percentages of false U-turn counts and missing U-turn counts compared to correct counts in the 2D view. These findings suggest that reducing the monitoring dimension may impact the accurate estimation of swimming motion, potentially resulting in inaccurate outcomes. Finally, the statistical analyses of the non-linear properties of fractal dimension revealed significant differences among the various monitoring methods. This conclusion has practical implications for biologists and physicists, enabling them to improve the accuracy of behavioral phenotyping for organisms exhibiting 3D motion.
引用
收藏
页码:929 / 938
页数:10
相关论文
共 50 条
  • [1] 2D and 3D Roughness Characterization
    Magsipoc, Earl
    Zhao, Qi
    Grasselli, Giovanni
    ROCK MECHANICS AND ROCK ENGINEERING, 2020, 53 (03) : 1495 - 1519
  • [2] Intraoperative comparison of 2D versus 3D transesophageal echocardiography for quantitative assessment of mitral regurgitation
    Lovhale, Pravin S.
    Gadhinglajkar, Shrinivas
    Sreedhar, Rupa
    Sukesan, Subin
    Pillai, Vivek
    ANNALS OF CARDIAC ANAESTHESIA, 2021, 24 (02) : 163 - 171
  • [4] 2D and 3D Roughness Coefficient of Marble Joint Surface
    Wang, Chenlin
    Guo, Baohua
    ELECTRONIC JOURNAL OF GEOTECHNICAL ENGINEERING, 2016, 21 (12): : 4359 - 4368
  • [5] Detecting and monitoring dental plaque levels with digital 2D and 3D imaging techniques
    Giese-Kraft, Katja
    Jung, Katja
    Schlueter, Nadine
    Vach, Kirstin
    Ganss, Carolina
    PLOS ONE, 2022, 17 (02):
  • [6] Fast computation of fractal dimension for 2D, 3D and 4D data
    Ruiz de Miras, J.
    Posadas, M. A.
    Ibanez-Molina, A. J.
    Soriano, M. F.
    Iglesias-Parro, S.
    JOURNAL OF COMPUTATIONAL SCIENCE, 2023, 66
  • [7] Clinical feasibility and validation of 3D principal strain analysis from cine MRI: comparison to 2D strain by MRI and 3D speckle tracking echocardiography
    Satriano, Alessandro
    Heydari, Bobak
    Narous, Mariam
    Exner, Derek V.
    Mikami, Yoko
    Attwood, Monica M.
    Tyberg, John V.
    Lydell, Carmen P.
    Howarth, Andrew G.
    Fine, Nowell M.
    White, James A.
    INTERNATIONAL JOURNAL OF CARDIOVASCULAR IMAGING, 2017, 33 (12) : 1979 - 1992
  • [8] Comparison between 2D and 3D Echocardiography in the Evaluation of Reverse Remodeling after CRT
    Hotta, Viviane Tiemi
    Martinelli Filho, Martino
    Mady, Charles
    Mathias, Wilson, Jr.
    Campos Vieira, Marcelo Luiz
    ARQUIVOS BRASILEIROS DE CARDIOLOGIA, 2011, 97 (02) : 111 - 121
  • [9] The Role of 2D and 3D Echo in Mitral Stenosis
    Monteagudo Ruiz, Juan Manuel
    Gomez, Jose Luis Zamorano
    JOURNAL OF CARDIOVASCULAR DEVELOPMENT AND DISEASE, 2021, 8 (12)
  • [10] MULTIFRAC: An ImageJ plugin for multiscale characterization of 2D and 3D stack images
    Torre, Ivan G.
    Heck, Richard J.
    Tarquis, A. M.
    SOFTWAREX, 2020, 12