Experimental Investigation of Solar-Driven Hollow Fiber Membrane Liquid Dehumidification System

被引:3
作者
Liang, Cai-Hang [1 ]
Hu, Jia-Li [1 ]
Li, Nan-Feng [1 ]
He, Zhi-Peng [1 ]
Mo, Chou [1 ]
Zeng, Si [1 ,2 ]
机构
[1] Guilin Univ Elect Technol, Sch Mech & Elect Engn, Guangxi Dept Educ, Key Lab Microelect Packaging & Assembly Technol, Guilin 541004, Peoples R China
[2] Guangxi Beitou Environm Protect & Water Grp Co Ltd, Nanning 530025, Peoples R China
关键词
hollow fiber membrane; liquid dehumidification; solar energy regeneration; experimental research; DESICCANT AIR DEHUMIDIFICATION; MASS-TRANSFER; HEAT; PERFORMANCE; MODULE;
D O I
10.3390/membranes13040383
中图分类号
Q5 [生物化学]; Q7 [分子生物学];
学科分类号
071010 ; 081704 ;
摘要
The hollow fiber membrane modules act as dehumidifiers and regenerators to avoid gas-liquid entrainment problems in direct-contact dehumidification systems. A solar-driven hollow fiber membrane dehumidification experimental rig was designed to investigate its performance from July to September in Guilin, China. The dehumidification, regeneration, and cooling performance of the system between 8:30 and 17:30 are analyzed. The energy utilization of the solar collector and system is investigated. The results show that solar radiation has a significant influence on the system. The hourly regeneration of the system has the same trend as the temperature of solar hot water, which ranges from 0.13 g/s to 0.36 g/s. The regeneration capacity of the dehumidification system is always larger than the dehumidification capacity after 10:30, which increases the solution concentration and the dehumidification performance. Further, it ensures stable system operation when the solar radiation is lower (15:30-17:50). In addition, the hourly dehumidification capacity and efficiency of the system ranges from 0.15 g/s to 0.23 g/s and 52.4 to 71.3%, respectively, with good dehumidification performance. The COP of the system and solar collector have the same trend, in which their maximum values are 0.874 and 0.634, respectively, with high energy utilization efficiency. The solar-driven hollow fiber membrane liquid dehumidification system performs better in regions with larger solar radiation.
引用
收藏
页数:17
相关论文
共 32 条
[1]   Thermo-economic performance of a solar membrane liquid desiccant air conditioning system [J].
Abdel-Salam, Ahmed H. ;
Ge, Gaoming ;
Simonson, Carey J. .
SOLAR ENERGY, 2014, 102 :56-73
[2]   Performance analysis of a membrane liquid desiccant air-conditioning system [J].
Abdel-Salam, Ahmed H. ;
Ge, Gaoming ;
Simonson, Carey J. .
ENERGY AND BUILDINGS, 2013, 62 :559-569
[3]   Solar-Assisted Liquid Desiccant Dehumidification Using Hollow-Fiber and Parallel-Plate Membrane Dehumidifiers: Comparative Analysis [J].
Bahaidaraha, Haitham M. ;
Mohamed, Mohand H. ;
Mokheimer, Esmail M. A. .
JOURNAL OF ENERGY RESOURCES TECHNOLOGY-TRANSACTIONS OF THE ASME, 2019, 141 (12)
[4]   Steady-state performance evaluation and energy assessment of a complete membrane-based liquid desiccant dehumidification system [J].
Bai, Hongyu ;
Zhu, Jie ;
Chen, Xiangjie ;
Chu, Junze ;
Cui, Yuanlong ;
Yan, Yuying .
APPLIED ENERGY, 2020, 258
[5]   Experimental and theoretical analysis of air humidification/dehumidification processes using hydrophobic capillary contactors [J].
Bergero, S ;
Chiari, A .
APPLIED THERMAL ENGINEERING, 2001, 21 (11) :1119-1135
[6]   On the performances of a hybrid air-conditioning system in different climatic conditions [J].
Bergero, Stefano ;
Chiari, Anna .
ENERGY, 2011, 36 (08) :5261-5273
[7]  
China Associate of Building Energy Efficiency, 2020, China Building Energy Consumption Research Report
[8]   Performance characteristics of cross-flow membrane contactors for liquid desiccant systems [J].
Das, Rajat Subhra ;
Jain, Sanjeev .
APPLIED ENERGY, 2015, 141 :1-11
[9]  
Energy Efficiency & Renewable Energy Energy Savings Potential and RD&D, OPP NONV COMPR HVAC
[10]  
Gurubalan A., 2018, P INT REFR AIR COND, P1920