Haptic Erosion Following Sutureless Scleral-fixated Intraocular Lens Placement

被引:6
作者
Pakravan, Parastou [1 ]
Patel, Veshesh [1 ]
Chau, Viet [1 ]
Rohowetz, Landon [1 ]
Lai, James [1 ]
Fan, Kenneth C. [1 ]
Al-khersan, Hasenin [1 ]
Melo, Isabela M. [2 ]
Muni, Rajeev H. [2 ]
Tsao, Sean W. [3 ]
Kaplan, Richard [4 ]
Jung, Jesse J. [5 ,6 ]
Hoyek, Sandra [7 ]
Patel, Nimesh A. [7 ]
Kuriyan, Ajay E. [8 ]
Laura, Diana M. [1 ]
Mantopoulos, Dimosthenis [9 ]
Syed, Zeba A. [7 ]
Yannuzzi, Nicolas A. [10 ]
机构
[1] Univ Miami, Bascom Palmer Eye Inst, Miller Sch Med, Miami, FL USA
[2] Univ Toronto, Toronto, ON, Canada
[3] Southern Calif Permanente Med Grp, Dept Ophthalmol, Santa Ana, CA USA
[4] Connecticut Retina Consultants, Fairfield, CT USA
[5] Univ Calif San Francisco, Dept Ophthalmol, San Francisco, CA USA
[6] East Bay Retina Consultants Inc, Oakland, CA USA
[7] Harvard Univ, Massachusetts Eye & Ear Infirm, Boston, MA USA
[8] Thomas Jefferson Univ Hosp, Wills Eye Hosp, Sidney Kimmel Med Coll, Philadelphia, PA USA
[9] Geisel Sch Med Dartmouth, New Hampshire, Hanover, Jamaica
[10] 900 NW 17th St, Miami, FL 33136 USA
来源
OPHTHALMOLOGY RETINA | 2023年 / 7卷 / 04期
关键词
Sutureless scleral-fixated intraocular lens; Haptic erosion; SURGICAL TECHNIQUE; CLINICAL-OUTCOMES; RESCUE; TUNNEL;
D O I
10.1016/j.oret.2022.10.015
中图分类号
R77 [眼科学];
学科分类号
100212 ;
摘要
Purpose: To describe the clinical features and visual outcomes of eyes with conjunctival haptic erosion after sutureless intrascleral (SIS) fixated intraocular lens (IOL) placement.Design: Retrospective case series.Subjects: Patients experiencing haptic erosion after SIS fixation between January 1, 2013, and March 1, 2022.Methods: A multicenter, multisurgeon, retrospective review.Main Outcome Measures: Clinical features, visual outcomes, and treatment options following haptic ero-sions after SIS fixation.Results: Nineteen eyes with haptic erosion were identified. The mean age at initial SIS fixation was 64 +/- 12 years (range, 38-81 years). There were 5 (26%) eyes with a history of conjunctiva involving ocular surgery, including scleral buckle surgery and tube shunt surgery. Trocar-assisted fixation was performed in 15 (79%) eyes, whereas needle fixation was used in 4 (21%) eyes. Eighteen (95%) sets of haptics were flanged with a low temperature cautery. Seventeen (90%) sets of haptics were externalized superiorly and inferiorly, and 2 (10%) sets of haptics were externalized nasally and temporally. Haptics were covered by conjunctiva in 14 (74%) eyes and by scleral flap in 5 (26%) eyes. All patients experienced a single haptic erosion, of which 8 (43%) were located superiorly, 9 (47%) inferiorly, and 2 (10%) temporally. The mean interval between the initial SIS fixation and haptic erosion was 278 +/- 437 days. After correction of the erosion, 18 (95%) eyes had a stable IOL at the last follow-up, with no recurrence of haptic erosion. In this series, there were no cases of endophthalmitis.Conclusions: Haptic erosion is a notable complication after SIS fixated IOL surgery but may be repaired with favorable visual outcomes. Careful evaluation of the conjunctiva should be considered before the surgery.Financial Disclosure(s): Proprietary or commercial disclosure may be found after the references. Ophthalmology Retina 2023;7:333-337 (c) 2022 by the American Academy of Ophthalmology
引用
收藏
页码:333 / 337
页数:5
相关论文
共 22 条
  • [1] Fibrin glue-assisted sutureless posterior chamber intraocular lens implantation in eyes with deficient posterior capsules
    Agarwal, Amar
    Kumar, Dhivya Ashok
    Jacob, Soosan
    Baid, Chandresh
    Agarwal, Athiya
    Srinivasan, Sridhar
    [J]. JOURNAL OF CATARACT AND REFRACTIVE SURGERY, 2008, 34 (09) : 1433 - 1438
  • [2] Scleral tunnel with conjunctival autograft for rescue management of extruded haptic: Surgical technique and review of literature
    Agarwal, Rinky
    Todi, Vishnu
    Bafna, Rahul Kumar
    Asif, Md Ibrahime
    Sharma, Namrata
    [J]. INDIAN JOURNAL OF OPHTHALMOLOGY, 2021, 69 (03) : 758 - 761
  • [3] Outcomes of Flanged Intrascleral Haptic Fixation with CT Lucia Three-Piece Intraocular Lens
    Fan, Kenneth C.
    Patel, Nimesh A.
    Al-Khersan, Hasenin
    Townsend, Justin H.
    [J]. OPHTHALMIC SURGERY LASERS & IMAGING RETINA, 2021, 52 (12) : 658 - 662
  • [4] Gelman Rachel A, 2019, Am J Ophthalmol Case Rep, V14, P101, DOI 10.1016/j.ajoc.2019.03.009
  • [5] 27-gauge trocar-assisted sutureless intraocular lens fixation
    Jujo, Tatsuya
    Kogo, Jiro
    Sasaki, Hiroki
    Sekine, Reio
    Sato, Keiji
    Ebisutani, Sakura
    Toyoda, Yasuhiro
    Kitaoka, Yasushi
    Takagi, Hitoshi
    [J]. BMC OPHTHALMOLOGY, 2021, 21 (01)
  • [6] SURGICAL OUTCOME OF SIMULTANEOUS INTRAOCULAR LENS RESCUE AND SUTURELESS INTRASCLERAL TUNNEL FIXATION OF DISLOCATED INTRAOCULAR LENSES
    Kim, Min
    Lee, Dong H.
    Koh, Hyoung J.
    Lee, Sung C.
    Kim, Sung S.
    [J]. RETINA-THE JOURNAL OF RETINAL AND VITREOUS DISEASES, 2015, 35 (07): : 1450 - 1457
  • [7] Risk Factors for Tube Shunt Exposure: A Matched Case-Control Study
    Koval, Michael S.
    El Sayyad, Fouad F.
    Bell, Nicholas P.
    Chuang, Alice Z.
    Lee, David A.
    Hypes, Stephen M.
    Grover, Davinder S.
    Baker, Laura A.
    Huddleston, Stephen M.
    Budenz, Donald L.
    Feldman, Robert M.
    [J]. JOURNAL OF OPHTHALMOLOGY, 2013, 2013 : 1 - 5
  • [8] Glued intraocular lens: a major review on surgical technique and results
    Kumar, Dhivya Ashok
    Agarwal, Amar
    [J]. CURRENT OPINION IN OPHTHALMOLOGY, 2013, 24 (01) : 21 - 29
  • [9] Glaucoma Drainage Devices: Risk of Exposure and Infection
    Levinson, Joshua D.
    Giangiacomo, Annette L.
    Beck, Allen D.
    Pruett, Paul B.
    Superak, Hillary M.
    Lynn, Michael J.
    Costarides, Anastasios P.
    [J]. AMERICAN JOURNAL OF OPHTHALMOLOGY, 2015, 160 (03) : 516 - 521
  • [10] Long-Term Stability of Intraocular Lens with Trimmed or Untrimmed Haptics in Yamane Sutureless Intrascleral Fixation Technique
    Lin, Hui
    Ye, Xiancheng
    Huang, Xinyu
    Li, Houshuo
    Wang, Zhen
    Niu, Yunli
    Bi, Yanlong
    [J]. MEDICAL SCIENCE MONITOR, 2021, 27