A Comparison of the Corneal Thickness Following Descemet's Stripping Automated Endothelial Keratoplasty and Descemet's Membrane Endothelial Keratoplasty

被引:0
作者
Sunouchi, Chihiro [1 ]
Hayashi, Takahiko [1 ,2 ,7 ]
Shimizu, Toshiki [1 ]
Hara, Yusuke [1 ]
Kurita, Junki [1 ]
Kobashigawa, Hiroko [3 ]
Oyakawa, Itaru [4 ]
Ida, Yasutsugu [2 ]
Kobayashi, Akira [5 ]
Shoji, Jun [1 ,6 ]
Yamagami, Satoru [1 ]
机构
[1] Nihon Univ Med, Dept Ophthalmol, Tokyo, Japan
[2] Yokohama Minami Kyosai Hosp, Dept Ophthalmol, Kanagawa, Japan
[3] Yokosuka Chuo Eye Clin, Kanagawa, Japan
[4] Heart Life Hosp, Dept Ophthalmol, Okinawa, Japan
[5] Kanazawa Univ, Grad Sch Med Sci, Dept Ophthalmol, Ishikawa, Japan
[6] Shoji Eye Clin, Chiba, Japan
[7] Nihon Univ Med, Dept Ophthalmol, 30-1 Oyaguchikamimachi,Itabashi Ku, Tokyo 1738610, Japan
关键词
Descemet's stripping automated endothelial keratoplasty; Descemet's membrane endothelial keratoplasty; central corneal thickness; recipient corneal thickness; corneal thinning;
D O I
10.1080/02713683.2023.2203424
中图分类号
R77 [眼科学];
学科分类号
100212 ;
摘要
PurposeTo compare the central corneal thickness before and after Descemet's stripping automated endothelial keratoplasty (DSAEK) and Descemet's membrane endothelial keratoplasty (DMEK), and to evaluate the recipient corneal thickness following DSAEK.MethodsThe corneal thickness was compared between two groups of eyes following DMEK and DSAEK, performed by a single surgeon between 2015 and 2017. We evaluated the recipient corneal thickness and central corneal thickness pre- and postoperatively at 1, 3, and 6 months using anterior segment optical coherence tomography. Recipient corneal thickness was defined as the corneal thickness without graft thickness.ResultsWe included DMEK and DSAEK eyes (n = 26 each), which were similar in terms of their etiologies. Preoperatively, there was no significant difference in the central corneal thickness between the groups (DSAEK, median [interquartile range]: 721 [606.5 to 847.8] mu m; and DMEK: 690 [618 to 722.3] mu m; p = 0.30). Despite the tendency of the central corneal thickness to be significantly greater (p < .01) at 6 months following DSAEK (619.5 [607.8 to 661.3] mu m) compared with that following DMEK (497.5 [475.8 to 525.3] mu m), there was no significant difference at 6 months between the recipient corneal thickness following DSAEK (488.5 [443.8 to 515] mu m) and central corneal thickness following DMEK (p = 0.54).ConclusionsDSAEK eyes display a similar tendency of stromal thinning as DMEK eyes.
引用
收藏
页码:712 / 718
页数:7
相关论文
共 44 条
[41]   A simple surgical technique for splitting a single donor cornea for performing deep anterior lamellar keratoplasty and Descemet membrane endothelial keratoplasty without using a microkeratome [J].
Siddharthan, K. S. ;
Agrawal, Anushri ;
Reddy, Jagdeesh Kumar .
INDIAN JOURNAL OF OPHTHALMOLOGY, 2021, 69 (09) :2441-+
[42]   Comparison of Intraocular Pressure Measurements With Goldmann Applanation Tonometry, Tonopen XL, and Pascal Dynamic Contour Tonometry in Patients With Descemet Membrane Endothelial Keratoplasty [J].
Yildiz, Izlem ;
Altan, Cigdem ;
Cakmak, Semih ;
Genc, Selim ;
Yildirim, Yusuf ;
Agca, Alper .
JOURNAL OF GLAUCOMA, 2022, 31 (11) :909-914
[43]   The feasibility and efficacy of preparing porcine Descemet's membrane endothelial keratoplasty (DMEK) grafts by two techniques: An ex-vivo investigation for future xeno-DMEK [J].
Liu, Yang ;
Zhang, Jing ;
Zhang, Yingnan ;
Yin, Mingyang ;
Miao, Sen ;
Liang, Qingfeng ;
Pan, Zhiqiang .
XENOTRANSPLANTATION, 2018, 25 (05)
[44]   "Endothelium-Out" and "Endothelium-In" Descemet Membrane Endothelial Keratoplasty (DMEK) Graft Insertion Techniques: A Systematic Review With Meta-Analysis [J].
Ong, Hon Shing ;
Htoon, Hla M. ;
Ang, Marcus ;
Mehta, Jodhbir S. .
FRONTIERS IN MEDICINE, 2022, 9