摘要
The scientific community has continued to pay particular attention to potentiometric sensors based on ion-selective membrane sensors as an energy-efficient, easy-to-use method suitable for microfabrication. To this end, potentiometric ion-selective sensors were used as an alternative green analytical instrument. Three distinct sensors relying on various ionophores were built and assessed. A cationic exchanger, tetra phenyl borate, was used in the polyvinyl chloride polymeric plasticized matrix using di octyl phthalate, where alpha, beta, and gamma cyclodextrins were utilized as ionophores. A comparative potentiometric analysis was carried out using three ion-selective sensor designs: alpha, beta, and gamma cyclodextrins sensors. beta-Cyclodextrin significantly reduced the detection limit and improved the discriminative performance of mebeverine hydrochloride (MBV) in the pharmaceutical dosage form over alpha- and gamma-cyclodextrins in the presence of other interfering chemicals. Additionally, a significant connection was made between the practical perspective and a theoretical investigation based on computational research. Nernstian potentiometric results for the optimum sensor were obtained for MBV in the range of concentrations 1.0 x 10(-2) to 1.0 x 10(-6) M, its slope was -58.70 +/- 0.12 mV per decade with lower detection limits 4.50 x 10(-7) M. This computational molecular docking investigation clarified that the binding sites and modes were in good agreement with the experiment results. This investigation was applied to expect the interaction between MBV and the proposed sensors to ensure which ionophores were the best for MBV.
引用
收藏
页码:1085 / 1093
页数:9
相关论文
共 30 条
  • [1] SENSITIVE HIGH-PERFORMANCE LIQUID-CHROMATOGRAPHIC DETERMINATION OF MEBEVERINE IN PLASMA USING FLUORESCENCE DETECTION
    ALANGARY, AA
    KHIDR, SH
    ABDELHADY, SS
    BAYOMI, MA
    MAHROUS, GM
    [J]. ANALYTICAL LETTERS, 1992, 25 (07) : 1251 - 1260
  • [2] Quantitative analysis of mebeverine in dosage forms by HPLC
    AlDeeb, O
    AlHadiya, BM
    Foda, NH
    [J]. CHROMATOGRAPHIA, 1997, 44 (7-8) : 427 - 430
  • [3] Ali M.S., 2014, DIYALA J PURE SCI, V10, P76
  • [4] Arayne M Saeed, 2005, Pak J Pharm Sci, V18, P11
  • [5] DERIVATIVE SPECTROPHOTOMETRIC DETERMINATION OF GLIBENCLAMIDE, MEBEVERINE HYDROCHLORIDE AND CLOPAMIDE IN THE PRESENCE OF THEIR ALKALINE-INDUCED DEGRADATION PRODUCTS
    BEDAIR, MM
    KORANY, MA
    EBDELHAY, MA
    GAZY, AA
    [J]. ANALYST, 1990, 115 (04) : 449 - 453
  • [6] RECOMMENDATIONS FOR NOMENCLATURE OF ION-SELECTIVE ELECTRODES - (IUPAC RECOMMENDATIONS 1994)
    BUCK, RP
    LINDNER, E
    [J]. PURE AND APPLIED CHEMISTRY, 1994, 66 (12) : 2527 - 2536
  • [7] Cyclodextrin-Drug Inclusion Complexes: In Vivo and In Vitro Approaches
    Carneiro, Simone Braga
    Costa Duarte, Fernanda Ilary
    Heimfarth, Luana
    Siqueira Quintans, Jullyana de Souza
    Quintans-Junior, Lucindo Jose
    da Veiga Junior, Valdir Florencio
    Neves de Lima, Adley Antonini
    [J]. INTERNATIONAL JOURNAL OF MOLECULAR SCIENCES, 2019, 20 (03)
  • [8] Application of first-derivative UV spectrophotometry, TLC-densitometry and liquid chromatography for the simultaneous determination of mebeverine hydrochloride and sulpiride
    El Walily, AFM
    El Gindy, A
    Bedair, MF
    [J]. JOURNAL OF PHARMACEUTICAL AND BIOMEDICAL ANALYSIS, 1999, 21 (03) : 535 - 548
  • [9] Carbon Nanotubes Modified Electrode for Enhanced Voltammetric Sensing of Mebeverine Hydrochloride in Formulations and Human Serum Samples
    El-Desoky, Hanaa S.
    Ghoneim, Mohamed M.
    El-Badawy, Fared M.
    [J]. JOURNAL OF THE ELECTROCHEMICAL SOCIETY, 2017, 164 (06) : B212 - B222
  • [10] Spectrophotometric determination of benzydamine HCl, levamisole HCl and mebeverine HCl through ion-pair complex formation with methyl orange
    El-Didamony, Akram M.
    [J]. SPECTROCHIMICA ACTA PART A-MOLECULAR AND BIOMOLECULAR SPECTROSCOPY, 2008, 69 (03) : 770 - 775