Subcutaneous implantable cardioverter-defibrillator implantation position predicts successful defibrillation in obese and non-obese patients

被引:7
|
作者
Hoster, Clay [1 ]
Rahman, Annas [1 ]
Goyal, Ansh [2 ]
Peigh, Graham [2 ]
Trohman, Richard [1 ]
Knight, Bradley P. P. [2 ]
Huang, Henry [1 ]
Krishnan, Kousik [3 ]
Larsen, Timothy [1 ]
Mazur, Alexander [1 ]
Sharma, Parikshit [1 ]
Engelstein, Erica [1 ]
Verma, Nishant [2 ]
Wasserlauf, Jeremiah [1 ]
机构
[1] Rush Univ, Div Cardiol, Med Ctr, 1717 W Congress Pkwy, 345 Kellogg, Chicago, IL 60612 USA
[2] Northwestern Univ, Feinberg Sch Med, Div Cardiol, Chicago, IL USA
[3] Midwest Cardiovasc Inst, Naperville, IL USA
关键词
ICD; S-ICD; Defibrillation; Obesity; PRAETORIAN;
D O I
10.1007/s10840-022-01462-z
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Background Subcutaneous implantable cardioverter-defibrillators (S-ICD) are an alternative to transvenous ICDs for patients without a need for cardiac pacing. Obese patients have been proposed to be at higher risk for conversion failure with S-ICDs due to subcutaneous fat underneath the device. Optimal device positioning may promote equivalent outcomes between obese and non-obese patients by minimizing the effects of excess adipose tissue. Methods A retrospective analysis of patients undergoing defibrillation testing at the time of S-ICD implantation was performed. The primary endpoint was the rate of successful conversion of ventricular fibrillation (VF) at the time of implant. The secondary endpoint was shock impedance. Results A total of 184 patients were included in the study. The rate of successful conversion of VF was 90.3% for obese patients (n = 72) and 96.4% for non-obese patients (n = 112) (p = 0.086). Compared to non-obese patients, obese patients had a higher mean PRAETORIAN score (78.5 +/- 58.1 vs. 48.8 +/- 35.5, p < 0.001) and higher measured mean impedance (82.0 ohms +/- 26.5 vs. 69.8 ohms +/- 19.3, p < 0.001). Patients with a PRAETORIAN score < 90 all had successful defibrillation testing regardless of BMI. Conclusions In this study, a PRAETORIAN score < 90 was associated with a 100% success rate of defibrillation testing following S-ICD implantation regardless of patient body mass index (BMI). Thus, the impact of obesity on impedance and the risk of failed shocks may be minimized with close attention to implantation technique to achieve a low PRAETORIAN score.
引用
收藏
页数:7
相关论文
共 50 条
  • [1] Outcomes of Subcutaneous Implantable Cardioverter-Defibrillator Procedures in Obese versus Non-Obese Patients: A Retrospective Cohort Study
    Hoster, Clay
    Huang, Henry
    Larsen, Timothy
    Krishnan, Kousik
    Trohman, Richard
    Peigh, Graham
    Verma, Nishant
    Sharma, Parikshit
    Wasserlauf, Jeremiah
    CIRCULATION, 2021, 144
  • [2] Subcutaneous Implantable Cardioverter-Defibrillator Implantation Without Defibrillation Testing
    Miller, Marc A.
    Palaniswamy, Chandrasekar
    Dukkipati, Srinivas R.
    Balulad, Sujata
    Smietana, Jeffrey
    Vigdor, Aaron
    Koruth, Jacob S.
    Choudry, Subbarao
    Whang, William
    Reddy, Vivek Y.
    JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 2017, 69 (25) : 3118 - 3119
  • [3] Intermuscular Subcutaneous Implantable Cardioverter-Defibrillator Implantation Without Defibrillation Testing
    Mistry, Amar
    Pooranachandran, Vivetha
    Dhutia, Harshil
    Chelliah, Rajesh
    Pathmanathan, Ravi K.
    JACC-CLINICAL ELECTROPHYSIOLOGY, 2021, 7 (01) : 124 - 126
  • [4] Subserratus implantation of the subcutaneous implantable cardioverter-defibrillator
    Smietana, Jeffrey
    Frankel, David S.
    Serletti, Joseph M.
    Arkles, Jeffrey
    Pothineni, Naga Venkata K.
    Marchlinski, Francis E.
    Schaller, Robert D.
    HEART RHYTHM, 2021, 18 (10) : 1799 - 1804
  • [5] Successful defibrillation testing in patients undergoing elective subcutaneous implantable cardioverter-defibrillator generator replacement
    de Veld, Jolien A.
    Pepplinkhuizen, Shari
    van der Stuijt, Willeke
    Quast, Anne-Floor B. E.
    Nordkamp, Louise R. A. Olde
    Kooiman, Kirsten M.
    Wilde, Arthur A. M.
    Smeding, Lonneke
    Knops, Reinoud E.
    EUROPACE, 2023, 25 (07):
  • [6] Outcomes of subcutaneous implantable cardioverter-defibrillator implantation in patients on hemodialysis
    Koman, Eduard
    Gupta, Ashwani
    Subzposh, Faiz
    Saltzman, Heath
    Kutalek, Steven P.
    JOURNAL OF INTERVENTIONAL CARDIAC ELECTROPHYSIOLOGY, 2016, 45 (02) : 219 - 223
  • [7] Outcomes of subcutaneous implantable cardioverter-defibrillator implantation in patients on hemodialysis
    Eduard Koman
    Ashwani Gupta
    Faiz Subzposh
    Heath Saltzman
    Steven P Kutalek
    Journal of Interventional Cardiac Electrophysiology, 2016, 45 : 219 - 223
  • [8] Managing elevated subcutaneous implantable cardioverter-defibrillator defibrillation thresholds: The importance of implantation technique
    Ip, James E.
    JOURNAL OF CARDIOVASCULAR ELECTROPHYSIOLOGY, 2021, 32 (04) : 1205 - 1208
  • [9] Successful implantation of subcutaneous implantable cardioverter-defibrillator in a patient with severe pectus excavatum
    Karvouni, Evangelia
    Zografos, Theodoros
    Winter, Joachim
    Katritsis, Demosthenes
    EUROPACE, 2018, 20 (11): : 1848 - 1848
  • [10] Successful Implantation of Cardioverter-Defibrillator Systems in Patients With Elevated Defibrillation Thresholds
    Brooks, Ross
    Torchiana, David
    Vlahakes, Gus J.
    Ruskin, Jeremy N.
    McGovern, Brian A.
    Garan, Hasan
    JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 1993, 22 (02) : 569 - 574