Retention of Different Attachment Systems for Digitally Designed Mandibular Implant Overdenture

被引:14
作者
Abdelaziz, Medhat Sameh [1 ]
Fawzy, Aya Mohamed [1 ]
Ghali, Rami Maher [2 ]
Nassar, Hossam, I [1 ]
机构
[1] Future Univ Egypt, Fac Oral & Dent Med, Dept Prosthodont, End 90 St, Cairo 11835, Egypt
[2] Ain Shams Univ, Fac Dent, Dept Prosthodont, Cairo, Egypt
来源
JOURNAL OF PROSTHODONTICS-IMPLANT ESTHETIC AND RECONSTRUCTIVE DENTISTRY | 2023年 / 32卷 / 02期
关键词
attachments; dental implants; overdenture; retention; single digital-reinforced denture; FORCE; POLYETHERETHERKETONE; WEAR;
D O I
10.1111/jopr.13516
中图分类号
R78 [口腔科学];
学科分类号
1003 ;
摘要
Purpose Primary retention and gradual loss of retention of different attachment systems are important key factors in proper attachment selection; however, studies on attachment retention show a wide range of retention values concerning the same attachment system. This in vitro study uses a novel approach that utilizes a digitally designed and 3D-printed reinforced overdenture, which has a digitally determined geometric center, in order to standardize results for future research and clinical work. This study aims to evaluate initial retention along with the gradual loss of retention at different time intervals between three types of stud attachments, retaining a digitally designed, reinforced mandibular overdenture after 5475 cycles simulating 5 years of attachment usage. Materials and Methods An epoxy model of an ACP Class I (American College of Prosthodontists) edentulous mandible was constructed. A fully computer-designed surgical guide was employed after virtual denture design to place two implants according to prosthetically driven implant placement protocol. A metal meshwork with tissue stops was designed digitally to reinforce the denture and to carry the geometric center. The meshwork was incorporated into the denture-intaglio surface, which was planned for attachment pickup. Forty-eight digitally designed and metal-reinforced 3D-printed dentures were divided into four groups (12 dentures for each group). Loss of retention was measured to compare two novel Locator attachments (12 pairs of Locator R-TX, 12 pairs of Locator F-TX medium and low retention, with 12 pairs of ball and socket). Each group was subjected to an insertion and removal fatigue test resembling 5 years of patient usage. Retention values were recorded using a universal testing machine. Results Locator F-TX medium and low retention showed loss of retention by 91.93% and 92.91%, after fatigue testing equivalent to 2 and 3 years of use, respectively. Ball and socket and Locator R-TX showed loss of retention by 19.87% and 26.31%, respectively, after fatigue testing equivalent to 5 years of use. Conclusions Locator R-TX attachment systems showed promising retention for implant overdentures compared to ball and socket attachments. The proposed digital technique of denture reinforcement is capable of standardizing results for research and clinical work.
引用
收藏
页码:162 / 169
页数:8
相关论文
共 46 条
[1]   Milled Bar with PEEK and Metal Housings for Inclined Implants Supporting Mandibular Overdentures: 1-Year Clinical, Prosthetic, and Patient-Based Outcomes [J].
Abdraboh, Abdelrahman Elsaid ;
Elsyad, Moustafa Abdou ;
Mourad, Samah Ibrahim ;
Alameldeen, Hesham Ebrahim .
INTERNATIONAL JOURNAL OF ORAL & MAXILLOFACIAL IMPLANTS, 2020, 35 (05) :982-989
[2]  
Amato, 2018, COMPENDIUM, V39, P10
[3]  
Andreescu CF, 2018, MATER PLAST, V55, P124
[4]  
[Anonymous], 2001, Design and analysis of experiments
[5]  
[Anonymous], IBM SPSS Statistics for windows-version 20.0
[6]  
├a┬ustman P-O., 2018, COMPENDIUM, V39, P4
[7]   Retention force of plastic clips on implant bars: a randomized controlled trial [J].
Bayer, Stefan ;
Komor, Nathalie ;
Kramer, Annina ;
Albrecht, Dominic ;
Mericske-Stern, Regina ;
Enkling, Norbert .
CLINICAL ORAL IMPLANTS RESEARCH, 2012, 23 (12) :1377-1384
[8]   Retention force and fatigue strength of overdenture attachment systems [J].
Botega, DM ;
Mesquita, MF ;
Henriques, GEP ;
Vaz, LG .
JOURNAL OF ORAL REHABILITATION, 2004, 31 (09) :884-889
[9]   Retentive Properties of Two Stud Attachments with Polyetherketoneketone or Nylon Insert in Mandibular Implant Overdentures [J].
Choi, Jae-Won ;
Yun, Bo-Hyeok ;
Jeong, Chang-Mo ;
Huh, Jung-Bo .
INTERNATIONAL JOURNAL OF ORAL & MAXILLOFACIAL IMPLANTS, 2018, 33 (05) :1079-1088
[10]  
El Khourazaty, 2017, EGYPT DENT J, V63, P2701