An Adaptive Reclosing Scheme for Cross-Line Faults on Double-Circuit Wind Power Outgoing Lines with Shunt Reactors

被引:2
|
作者
Hu, Sen [1 ]
Xie, Chao [1 ]
Yin, Chunya [1 ]
机构
[1] Xinjiang Univ, Coll Elect Engn, Urumqi 830017, Peoples R China
关键词
transient fault; permanent failure; wind power outgoing line; adaptive reclosing; TRANSMISSION-LINES; AUTORECLOSING SCHEME; LOCATION; PROTECTION;
D O I
10.3390/en17061273
中图分类号
TE [石油、天然气工业]; TK [能源与动力工程];
学科分类号
0807 ; 0820 ;
摘要
Wind turbines are vulnerable to negative sequence current injection, the conventional automatic reclosing scheme for wind power outgoing lines, since we may inject negative sequence components into the system and reclose it without distinguishing the nature of the fault through rectification. Moreover, reclosing in permanent faults could induce a secondary impact on the system. To solve the above problems, an adaptive reclosing scheme for cross-line faults on double-circuit wind power outgoing lines with shunt reactors is proposed. Firstly, a new tripping strategy and a single-side partial-phase reclosing method are proposed for multiple types of outgoing line faults, while, simultaneously, phase-to-phase coupling loops are established. Secondly, the criteria of fault nature are established based on the fault phase shunt reactor current and fault phase voltage characteristics, and transient faults are rapidly and accurately distinguished from permanent ones according to the criteria. Finally, the theoretical derivation and simulation experiments are conducted on the PSCAD/EMTDC platform to demonstrate that the proposed adaptive reclosing method is applicable to avoid the injection of negative sequence currents into wind turbines. Meanwhile, the success rate of reclosing for wind power outgoing line is significantly improved and the continuity of power transmission on the wind farm(s) is ensured.
引用
收藏
页数:17
相关论文
共 36 条
  • [21] A novel phasor-based adaptive single-phase auto-reclosing scheme for transmission lines with shunt reactors
    Liu, Yangsheng
    Dou, Kun
    Xie, Xing
    Huang, Zebo
    Huang, Qian
    Guo, Zhenwei
    Luo, Yi
    Tang, Tao
    ELECTRICAL ENGINEERING, 2024, 106 (06) : 7231 - 7245
  • [22] A novel line parameter adaptive phasor domain fault location method for double-circuit transmission lines
    Liang, Yuansheng
    Zhang, Zihong
    Li, Haifeng
    Ding, Jiayan
    Wang, Gang
    Chen, Juan
    ELECTRIC POWER SYSTEMS RESEARCH, 2023, 214
  • [23] Adaptive three-phase auto-reclosing strategy based on capacitor voltage for power transmission lines with shunt reactors
    Huang F.
    Li F.
    Xie C.
    Wang T.
    Ma H.
    Bai H.
    Dianli Zidonghua Shebei/Electric Power Automation Equipment, 2020, 40 (06): : 170 - 176and197
  • [24] A distance Protection/Fault location algorithm for Double-Circuit transmission lines with asymmetrical circuits during Cross-Country faults
    Abdollahzadeh, Hamed
    INTERNATIONAL JOURNAL OF ELECTRICAL POWER & ENERGY SYSTEMS, 2023, 148
  • [25] Parameters Selection for the Neutral Arrester Beside Neutral Grounding Reactor at the Neutral Point of Shunt Reactors on 1 000 kV Double-circuit Line
    Zhou P.
    He H.
    Li Z.
    Wang L.
    Lou Y.
    Gaodianya Jishu/High Voltage Engineering, 2021, 47 (05): : 1606 - 1616
  • [26] Adaptive fast protection technique for uncompensated/compensated double-circuit transmission lines connected to large-scale wind farms
    Saber, Ahmed
    IET RENEWABLE POWER GENERATION, 2020, 14 (13) : 2315 - 2322
  • [27] Adaptive single-phase auto-reclosing scheme based on the moving average filter-quadrature signal generator for transmission lines with shunt reactors
    Xie, Xing
    Huang, Zebo
    Fan, Xingming
    Tang, Tao
    ELECTRIC POWER SYSTEMS RESEARCH, 2023, 223
  • [28] Anti-interference adaptive single-phase auto-reclosing schemes based on reactive power characteristics for transmission lines with shunt reactors
    Xie, Chao
    Li, Fengting
    Wang, Bin
    Fan, Yanfang
    Jing, Liuming
    Chen, Weiwei
    Wang, Cong
    ELECTRIC POWER SYSTEMS RESEARCH, 2019, 170 : 176 - 183
  • [29] Location of double-circuit grounded cross-country faults in GUPFC-compensated transmission lines based on current and voltage phasors analysis
    Abasi, Mahyar
    Saffarian, Alireza
    Joorabian, Mahmood
    Seifossadat, Seyed Ghodratollah
    ELECTRIC POWER SYSTEMS RESEARCH, 2021, 195
  • [30] New adaptive digital distance relaying scheme for double infeed parallel transmission line during inter-circuit faults
    Makwana, V. H.
    Bhalja, B.
    IET GENERATION TRANSMISSION & DISTRIBUTION, 2011, 5 (06) : 667 - 673