Spectral computed tomography angiography using a gadolinium-based contrast agent for imaging of pathologies of the aorta

被引:3
作者
Graf, Markus [1 ]
Gassert, Felix G. [1 ]
Marka, Alexander W. [1 ]
Gassert, Florian T. [1 ]
Ziegelmayer, Sebastian [1 ]
Makowski, Marcus [1 ]
Kallmayer, Michael [2 ]
Nadjiri, Jonathan [3 ,4 ]
机构
[1] Tech Univ Munich, Sch Med, Dept Diagnost & Intervent Radiol, Klinikum Rechts Isar, Ismaninger Str 22, D-81675 Munich, Germany
[2] Tech Univ Munich, Sch Med, Dept Vasc & Endovasc Surg, Klinikum Rechts Isar, Ismaninger Str 22, D-81675 Munich, Germany
[3] Tech Univ Munich, Sch Med, Dept Intervent Radiol, Ismaninger Str 22, D-81675 Munich, Germany
[4] Tech Univ Munich, Klinikum Rechts Isar, Ismaninger Str 22, D-81675 Munich, Germany
关键词
Aortic aneurysm; Spectral computed tomography angiography; Gadolinium; Dual energy; Monoenergetic reconstruction; DUAL-ENERGY CT; DETECTOR; PRINCIPLES; MANAGEMENT; IODINE; SAFETY;
D O I
10.1007/s10554-024-03074-2
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Objectives: Especially patients with aortic aneurysms and multiple computed tomography angiographies (CTA) might show medical conditions which oppose the use of iodine-based contrast agents. CTA using monoenergetic reconstructions from dual layer CT and gadolinium (Gd-)based contrast agents might be a feasible alternative in these patients. Therefore, the purpose of this study was to evaluate the feasibility of clinical spectral CTA with a Gd-based contrast agent in patients with aortic aneurysms. Methods: Twenty-one consecutive scans in 15 patients with and without endovascular aneurysm repair showing contraindications for iodine-based contrast agents were examined using clinical routine doses (0.2 mmol/kg) of Gd-based contrast agent with spectral CT. Monoenergetic reconstructions of the spectral data set were computed. Results: There was a significant increase in the intravascular attenuation of the aorta between pre- and post-contrast images for the MonoE40 images in the thoracic and the abdominal aorta (p < 0.001 for both). Additionally, the ratio between pre- and post-contrast images was significantly higher in the MonoE40 images as compared to the conventional images with a factor of 6.5 +/- 4.5 vs. 2.4 +/- 0.5 in the thoracic aorta (p = 0.003) and 4.1 +/- 1.8 vs. 1.9 +/- 0.5 in the abdominal aorta (p < 0.001). Conclusions: To conclude, our study showed that Gd-CTA is a valid and reliable alternative for diagnostic imaging of the aorta for clinical applications. Monoenergetic reconstructions of computed tomography angiographies using gadolinium based contrast agents may be a useful alternative in patients with aortic aneurysms and contraindications for iodine based contrast agents.
引用
收藏
页码:1059 / 1066
页数:8
相关论文
共 25 条
[11]   A systematic review and meta-analysis of the long-term outcomes of endovascular versus open repair of abdominal aortic aneurysm [J].
Li, Ben ;
Khan, Shawn ;
Salata, Konrad ;
Hussain, Mohamed A. ;
de Mestral, Charles ;
Greco, Elise ;
Aljabri, Badr A. ;
Forbes, Thomas L. ;
Verma, Subodh ;
Al-Omran, Mohammed .
JOURNAL OF VASCULAR SURGERY, 2019, 70 (03) :954-+
[12]   Dual- and Multi-Energy CT: Principles, Technical Approaches, and Clinical Applications [J].
McCollough, Cynthia H. ;
Leng, Shuai ;
Yu, Lifeng ;
Fletcher, Joel G. .
RADIOLOGY, 2015, 276 (03) :637-653
[13]   Energy Window Optimization for X-Ray K-Edge Tomographic Imaging [J].
Meng, Bo ;
Cong, Wenxiang ;
Xi, Yan ;
De Man, Bruno ;
Wang, Ge .
IEEE TRANSACTIONS ON BIOMEDICAL ENGINEERING, 2016, 63 (08) :1623-1630
[14]   Spectral Computed Tomography Angiography With a Gadolinium-based Contrast Agent: First Clinical Imaging Results in Cardiovascular Applications [J].
Nadjiri, Jonathan ;
Pfeiffer, Daniela ;
Straeter, Alexandra S. ;
Noel, Peter B. ;
Fingerle, Alexander ;
Eckstein, Hans-Henning ;
Laugwitz, Karl-Ludwig ;
Rummeny, Ernst J. ;
Braren, Rickmer ;
Rasper, Michael .
JOURNAL OF THORACIC IMAGING, 2018, 33 (04) :246-253
[15]   Iodine dose optimization in portal venous phase virtual monochromatic images of the abdomen: Prospective study on rapid kVp switching dual energy CT [J].
Noda, Yoshifumi ;
Goshima, Satoshi ;
Nakashima, Yuka ;
Miyoshi, Toshiharu ;
Kawai, Nobuyuki ;
Kambadakone, Avinash ;
Matsuo, Masayuki .
EUROPEAN JOURNAL OF RADIOLOGY, 2020, 122
[16]   Nephrotoxicity of high-dose gadolinium compared with iodinated contrast [J].
Prince, MR ;
Arnoldus, C ;
Frisoli, JK .
JMRI-JOURNAL OF MAGNETIC RESONANCE IMAGING, 1996, 6 (01) :162-166
[17]   Safety and effectiveness of gadolinium-enhanced multi-detector row spiral CT angiography of the chest: Preliminary results in 37 patients with contra-indications to iodinated contrast agents [J].
Remy-Jardin, M ;
Dequiedt, P ;
Ertzbischoff, O ;
Tillie-Leblond, I ;
Bruzzi, J ;
Duhamel, A ;
Remy, J .
RADIOLOGY, 2005, 235 (03) :819-826
[18]   Dual-Contrast Biphasic Liver Imaging With Iodine and Gadolinium Using Photon-Counting Detector Computed Tomography An Exploratory Animal Study [J].
Ren, Liqiang ;
Huber, Nathan ;
Rajendran, Kishore ;
Fletcher, Joel G. ;
McCollough, Cynthia H. ;
Yu, Lifeng .
INVESTIGATIVE RADIOLOGY, 2022, 57 (02) :122-129
[19]   Long-Term Renal Function after Endovascular Aneurysm Repair [J].
Saratzis, Athanasios ;
Bath, Michael F. ;
Harrison, Seamus ;
Sayers, Robert D. ;
Mahmood, Asif ;
Sarafidis, Pantelis ;
Bown, Matthew J. .
CLINICAL JOURNAL OF THE AMERICAN SOCIETY OF NEPHROLOGY, 2015, 10 (11) :1930-1936
[20]   Recent Advances in Computed Tomographic Technology: Cardiopulmonary Imaging Applications [J].
Tabari, Azadeh ;
Lo Gullo, Roberto ;
Murugan, Venkatesh ;
Otrakji, Alexi ;
Digumarthy, Subba ;
Kalra, Mannudeep .
JOURNAL OF THORACIC IMAGING, 2017, 32 (02) :89-100