共 25 条
Spectral computed tomography angiography using a gadolinium-based contrast agent for imaging of pathologies of the aorta
被引:3
作者:
Graf, Markus
[1
]
Gassert, Felix G.
[1
]
Marka, Alexander W.
[1
]
Gassert, Florian T.
[1
]
Ziegelmayer, Sebastian
[1
]
Makowski, Marcus
[1
]
Kallmayer, Michael
[2
]
Nadjiri, Jonathan
[3
,4
]
机构:
[1] Tech Univ Munich, Sch Med, Dept Diagnost & Intervent Radiol, Klinikum Rechts Isar, Ismaninger Str 22, D-81675 Munich, Germany
[2] Tech Univ Munich, Sch Med, Dept Vasc & Endovasc Surg, Klinikum Rechts Isar, Ismaninger Str 22, D-81675 Munich, Germany
[3] Tech Univ Munich, Sch Med, Dept Intervent Radiol, Ismaninger Str 22, D-81675 Munich, Germany
[4] Tech Univ Munich, Klinikum Rechts Isar, Ismaninger Str 22, D-81675 Munich, Germany
关键词:
Aortic aneurysm;
Spectral computed tomography angiography;
Gadolinium;
Dual energy;
Monoenergetic reconstruction;
DUAL-ENERGY CT;
DETECTOR;
PRINCIPLES;
MANAGEMENT;
IODINE;
SAFETY;
D O I:
10.1007/s10554-024-03074-2
中图分类号:
R5 [内科学];
学科分类号:
1002 ;
100201 ;
摘要:
Objectives: Especially patients with aortic aneurysms and multiple computed tomography angiographies (CTA) might show medical conditions which oppose the use of iodine-based contrast agents. CTA using monoenergetic reconstructions from dual layer CT and gadolinium (Gd-)based contrast agents might be a feasible alternative in these patients. Therefore, the purpose of this study was to evaluate the feasibility of clinical spectral CTA with a Gd-based contrast agent in patients with aortic aneurysms. Methods: Twenty-one consecutive scans in 15 patients with and without endovascular aneurysm repair showing contraindications for iodine-based contrast agents were examined using clinical routine doses (0.2 mmol/kg) of Gd-based contrast agent with spectral CT. Monoenergetic reconstructions of the spectral data set were computed. Results: There was a significant increase in the intravascular attenuation of the aorta between pre- and post-contrast images for the MonoE40 images in the thoracic and the abdominal aorta (p < 0.001 for both). Additionally, the ratio between pre- and post-contrast images was significantly higher in the MonoE40 images as compared to the conventional images with a factor of 6.5 +/- 4.5 vs. 2.4 +/- 0.5 in the thoracic aorta (p = 0.003) and 4.1 +/- 1.8 vs. 1.9 +/- 0.5 in the abdominal aorta (p < 0.001). Conclusions: To conclude, our study showed that Gd-CTA is a valid and reliable alternative for diagnostic imaging of the aorta for clinical applications. Monoenergetic reconstructions of computed tomography angiographies using gadolinium based contrast agents may be a useful alternative in patients with aortic aneurysms and contraindications for iodine based contrast agents.
引用
收藏
页码:1059 / 1066