Implementation of Individualized Low-Dose Computed Tomography-Guided Hook Wire Localization of Pulmonary Nodules: Feasibility and Safety in the Clinical Setting

被引:2
|
作者
Wei, Wei [1 ]
Wang, Shi-Geng [1 ]
Zhang, Jing-Yi [1 ]
Togn, Xiao-Yu [1 ]
Li, Bei-Bei [1 ]
Fang, Xin [1 ]
Pu, Ren-Wang [1 ]
Zhou, Yu-Jing [1 ]
Liu, Yi-Jun [1 ]
机构
[1] Dalian Med Univ, Affiliated Hosp 1, Dept Radiol, Dalian 116011, Peoples R China
关键词
hook wire; pulmonary nodules; radiation dosage; tomography; X-ray computed; ITERATIVE RECONSTRUCTION; NEEDLE-BIOPSY; CHEST CT; GUIDELINES; REDUCTION; EFFICACY; PROTOCOL;
D O I
10.3390/diagnostics13203235
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Background: CT-guided hook-wire localization is an essential step in the management of small pulmonary nodules. Few studies, however, have focused on reducing radiation exposure during the procedure. Purpose: This study aims to explore the feasibility of implementing a low-dose computed tomography (CT)-guided hook wire localization using tailored kVp based on patients' body size. Materials and Methods: A total of 151 patients with small pulmonary nodules were prospectively enrolled for CT-guided hook wire localization using individualized low-dose CT (LDCT) vs. standard-dose CT (SDCT) protocols. Radiation dose, image quality, characteristics of target nodules and procedure-related variables were compared. All variables were analyzed using Chi-Square and Student's t-test. Results: The mean CTDIvol was significantly reduced for LDCT (for BMI <= 21 kg/m(2), 0.56 +/- 0.00 mGy and for BMI > 21 kg/m(2), 1.48 +/- 0.00 mGy) when compared with SDCT (for BMI <= 21 kg/m(2), 5.24 +/- 0.95 mGy and for BMI > 21 kg/m(2), 6.69 +/- 1.47 mGy). Accordingly, the DLP of LDCT was significantly reduced as compared with that of SDCT (for BMI <= 21 kg/m(2), 56.86 +/- 4.73 vs. 533.58 +/- 122.06 mGy.cm, and for BMI > 21 kg/m(2), 167.02 +/- 38.76 vs. 746.01 +/- 230.91 mGy.cm). In comparison with SDCT, the effective dose (ED) of LDCT decreased by an average of 89.42% (for BMI <= 21 kg/m(2)) and 77.68% (for BMI > 21 kg/m(2)), respectively. Although the images acquired with the LDCT protocol yielded inferior quality to those acquired with the SDCT protocol, they were clinically acceptable for hook wire localization. Conclusions: LDCT-guided localization can provide safety and nodule detection performance comparable to SDCT-guided localization, benefiting radiation dose reduction dramatically, especially for patients with small body mass indexes.
引用
收藏
页数:10
相关论文
共 45 条
  • [21] Ultralow dose computed tomography protocol for hook-wire localization of solitary pulmonary nodules prior to video-assisted thoracoscopic surgery
    Liu, Bo
    Fang, Jie
    Jia, Haipeng
    Sun, Zhigang
    Liao, Jian
    Meng, Hong
    Pan, Fengmin
    Li, Chunhai
    THORACIC CANCER, 2019, 10 (06) : 1348 - 1354
  • [22] Preoperative computed tomography-guided localization for multiple pulmonary nodules: comparison of methylene blue and coil
    Zhang, Sheng-Feng
    Liu, Hai-Ri
    Ma, Ai-Li
    Li, Er-Liang
    JOURNAL OF CARDIOTHORACIC SURGERY, 2022, 17 (01)
  • [23] Video-assisted thoracoscopic surgery for pulmonary nodules: rationale for preoperative computed tomography-guided hookwire localization
    Ciriaco, P
    Negri, G
    Puglisi, A
    Nicoletti, R
    Del Maschio, A
    Zannini, P
    EUROPEAN JOURNAL OF CARDIO-THORACIC SURGERY, 2004, 25 (03) : 429 - 433
  • [24] The effectiveness and safety of computed tomography-guided hook-wire localization for secondary video-assisted thoracoscopic surgery: a retrospective study
    Xia, Tian
    Zhou, Ziyue
    Fang, Ziyao
    Xie, Zhuolin
    Shen, Ziqing
    Ding, Cheng
    Huang, Haitong
    Zhang, Yicheng
    Pan, Shu
    Zhao, Jun
    JOURNAL OF THORACIC DISEASE, 2024, 16 (12) : 8350 - 8362
  • [25] Preoperative computed tomography-guided localization for pulmonary nodules: a randomized controlled trial of coil and anchored needle localization
    Lv, Ya-Nan
    Zhang, Wen -Tao
    Wang, Ying
    Wang, Gang
    VIDEOSURGERY AND OTHER MINIINVASIVE TECHNIQUES, 2024, 19 (02) : 178 - 186
  • [26] Preoperative CT-guided localization of pulmonary nodules with low-dose radiation
    Ma, Yanhe
    Cheng, Shizhao
    Li, Jianhui
    Yuan, Wei
    Song, Zhenchun
    Zhang, Hong
    QUANTITATIVE IMAGING IN MEDICINE AND SURGERY, 2023, 13 (07) : 4295 - 4304
  • [27] Computed tomography-guided lung biopsy: a randomized controlled trial of low-dose versus standard-dose protocol
    Fu, Yu-Fei
    Li, Guang-Chao
    Xu, Qing-Song
    Shi, Yi-Bing
    Wang, Chen
    Wang, Tao
    EUROPEAN RADIOLOGY, 2020, 30 (03) : 1584 - 1592
  • [28] Success rates for computed tomography-guided musculoskeletal biopsies performed using a low-dose technique
    Motamedi, Kambiz
    Levine, Benjamin D.
    Seeger, Leanne L.
    McNitt-Gray, Michael F.
    SKELETAL RADIOLOGY, 2014, 43 (11) : 1599 - 1603
  • [29] Need for Preoperative Computed Tomography-Guided Localization in Video-Assisted Thoracoscopic Surgery Pulmonary Resections of Metastatic Pulmonary Nodules
    Nakashima, Shinji
    Watanabe, Atsushi
    Obama, Takuro
    Yamada, Gen
    Takahashi, Hiroki
    Higami, Tetsuya
    ANNALS OF THORACIC SURGERY, 2010, 89 (01): : 212 - +
  • [30] Computed tomography-guided lung biopsy: A meta-analysis of low-dose and standard-dose protocols
    Zhang, Ping
    Liu, Jing-Mei
    Zhang, Ying-Ying
    Hua, Rong
    Xia, Feng-Fei
    Shi, Yi-Bing
    JOURNAL OF CANCER RESEARCH AND THERAPEUTICS, 2021, 17 (03) : 695 - 701