Effect of low thermal conductivity wick on the performance of compact loop heat pipe

被引:1
作者
Veeramachaneni, Sireesha [1 ]
Pisipaty, Srinivas K. [2 ]
Solomon, Arulanantham Brusly [3 ]
Vadisa, Venkata C. [4 ]
Vedula, Dharma R. [1 ]
Rao, Devisetty Srinivasa [1 ]
机构
[1] Gayatri Vidya Parishad Coll Engn Autonomous, Dept Mech Engn, Visakhapatnam, India
[2] Andhra Univ, Coll Engn, Dept Mech Engn, Visakhapatnam, India
[3] Karunya Inst Technol & Sci, Ctr Res Mat Sci & Thermal Management, Dept Mech Engn, Coimbatore, India
[4] Birla Inst Technol & Sci, Dept Mech Engn, Pilani, Rajasthan, India
关键词
capillary rise; loop heat pipe; porosity; sintered chrysotile wick; wettability; CAPILLARY PERFORMANCE; COMPOSITE WICKS; FABRICATION; PARAMETERS;
D O I
10.1002/htj.22802
中图分类号
O414.1 [热力学];
学科分类号
摘要
The existing work deals with the evaluation of compact loop heat pipe by means of a low thermal conductivity sintered chrysotile wick to avoid large heat leaks as of the evaporator to the compensation chamber. Accordingly, a wick with low thermal conductivity (0.068-0.098 W/mK) chrysotile powder of a mean particle diameter of 3.4 mu m is fabricated through sintering. Nine chrysotile wicks are sintered with different compositions of binders (bentonite and dextrin) and pore-forming agent NaCl at sintering temperatures of 500 degrees C, 600 degrees C, and 700 degrees C with a sintering time of 30 min. The wick properties, for instance, porosity, permeability, wettability, and capillary rise are studied owing to sintering temperature. Consequently, it is observed that a pure chrysotile powdered wick at a sintering temperature of 600 degrees C exhibits a high porosity of 61.8% with permeability 1.04 x 10(-13) m(2) and a capillary rise of 4.5 cm in 30 s and is considered optimal. This optimal wick is used for performance evaluation in compact loop heat pipe and a decrease of 36.1% in thermal resistance is found when compared with copper mesh wick in a loop heat pipe. The lowermost thermal resistance originates to be 0.147 K/W at 120 W with wall temperature 57.7 degrees C. This indicates that loop heat pipe with sintered chrysotile wick can operate at lower heat loads efficiently when compared with copper mesh wick and as heat load increases a chance of dry out condition occurs. The highest evaporative heat transfer coefficient obtained is 65.7 kW/m(2) K at a minimum heat load.
引用
收藏
页码:2715 / 2742
页数:28
相关论文
共 50 条
[31]   Optimization of wick shape in a loop heat pipe for high heat transfer [J].
Nishikawara, M. ;
Nagano, H. .
INTERNATIONAL JOURNAL OF HEAT AND MASS TRANSFER, 2017, 104 :1083-1089
[32]   Parametric effects on heat transfer in loop heat pipe's wick [J].
Ren, Chuan .
INTERNATIONAL JOURNAL OF HEAT AND MASS TRANSFER, 2011, 54 (17-18) :3987-3999
[33]   Fractal Loop Heat Pipe performance testing with a compressed carbon foam wick structure [J].
Silk, Eric A. ;
Myre, David .
APPLIED THERMAL ENGINEERING, 2013, 59 (1-2) :290-297
[34]   Fabrication and thermal performance of porous crack composite wick flattened heat pipe [J].
Jiang, Lelun ;
Huang, Yong ;
Tang, Yong ;
Li, Yan ;
Zhou, Wei ;
Jiang, Linzhen ;
Gao, Jinwu .
APPLIED THERMAL ENGINEERING, 2014, 66 (1-2) :140-147
[35]   Heat transfer performance of a compact loop heat pipe with alumina and silver nanofluid [J].
Stephen, Emerald Ninolin ;
Asirvatham, Lazarus Godson ;
Kandasamy, Ramachandran ;
Solomon, Brusly ;
Kondru, Gnana Sundari .
JOURNAL OF THERMAL ANALYSIS AND CALORIMETRY, 2019, 136 (01) :211-222
[36]   Effect of inclination angle on the thermal performance of an ultrathin heat pipe with multi-scale wick structure [J].
Tang, Heng ;
Weng, Changxing ;
Tang, Yong ;
Lu, Yanjun ;
Fu, Ting .
INTERNATIONAL COMMUNICATIONS IN HEAT AND MASS TRANSFER, 2020, 118
[37]   Battery thermal management system using loop heat pipe with LTP copper capillary wick [J].
Ariantara, Bambang ;
Putra, Nandy ;
Supriadi, Sugeng .
2ND INTERNATIONAL TROPICAL RENEWABLE ENERGY CONFERENCE (I-TREC) 2017, 2018, 105
[38]   Investigation of the Polymer Wick Structure Applied to Loop Heat Pipe [J].
Wu, Shen-Chun ;
Hsieh, Bing-Han ;
Yeh, Chien-Chih ;
Chen, Yau-Ming .
IMPACT: 2009 4TH INTERNATIONAL MICROSYSTEMS, PACKAGING, ASSEMBLY AND CIRCUITS TECHNOLOGY CONFERENCE, 2009, :309-+
[39]   Effect of evaporator tilt on the operating temperature of a loop heat pipe without a secondary wick [J].
Bai, Lizhan ;
Lin, Guiping ;
Zhang, Hongxing ;
Wen, Dongsheng .
INTERNATIONAL JOURNAL OF HEAT AND MASS TRANSFER, 2014, 77 :600-603
[40]   Study of PTFE wick structure applied to loop heat pipe [J].
Wu, Shen-Chun ;
Gu, Tzu-Wei ;
Wang, Dawn ;
Chen, Yau-Ming .
APPLIED THERMAL ENGINEERING, 2015, 81 :51-57