Integrating FBN and FDS for quantitative risk assessment of cable fire in utility tunnel

被引:18
作者
Zhu, Xiaoping [1 ]
Wu, Jiansong [1 ]
Bai, Yiping [1 ]
Wang, Dong [2 ]
Zhang, Jun [3 ]
机构
[1] China Univ Min & Technol Beijing, Sch Emergency Management & Safety Engn, Beijing 100083, Peoples R China
[2] State Grid Corp China, Beijing 100031, Peoples R China
[3] State Grid Energy Res Inst Co Ltd, Beijing 102209, Peoples R China
基金
中国国家自然科学基金;
关键词
Utility tunnel; Cable fire; Risk assessment; Fuzzy bayesian network (FBN); Fire dynamic simulator (FDS); Safety barrier; SAFETY ASSESSMENT; STATIONS;
D O I
10.1016/j.jlp.2024.105266
中图分类号
TQ [化学工业];
学科分类号
0817 ;
摘要
The highly integrated underground utility tunnel (UUT) is a kind of critical infrastructure for process clusters and cities. However, this integration inevitably entails potential risks, including gas leakage, explosions, cable fires, and the accumulation of toxic gases within sewage pipes, and the concern regarding cable fires supersedes others due to their multifactorial correlations and severe consequences. Especially in utility tunnels within chemical industrial parks, cable fires can precipitate the shutdown of equipment, potentially culminating in grave incidents such as chemical leaks or uncontrolled reactions, owing to failures in control systems. This paper presents a novel dynamic risk assessment model for cable compartment fire in UUTs, integrating the Fuzzy Bayesian Network (FBN), Fire Dynamic Simulator (FDS). By employing sensitivity analysis and vulnerability path analysis techniques within the FBN framework, critical hazards associated with cable compartment fires are identified. Subsequently, a comprehensive FDS analysis is conducted for a standardized UUT cable compartment fire consequence, considering the chain response of the safety barriers. The obtained results reveal that even with normal safety barrier response, the risk in the early stage of a fire cannot be disregarded. Notably, among various safety barrier failure scenarios, the failure of a single fire door has the lowest integrated risk, while sensor failure may lead to a higher peak of integrated risk, as well as a higher average integrated risk due to sprinkler failure. The results indicate that the proposed model can offer practical supports in accident mitigation, risk management, and safety barrier optimization of cable compartments in UUTs.
引用
收藏
页数:19
相关论文
共 68 条
[1]   A study of expected lifetime of XLPE insulation cables working at elevated temperatures by applying accelerated thermal ageing [J].
Alghamdi, Abdulsalam S. ;
Desuqi, Rayan K. .
HELIYON, 2020, 6 (01)
[2]   Effects of interlayer distance and cable spacing on flame characteristics and fire hazard of multilayer cables in utility tunnel [J].
An, Weiguang ;
Wang, Tao ;
Liang, Kai ;
Tang, Yanhua ;
Wang, Zhe .
CASE STUDIES IN THERMAL ENGINEERING, 2020, 22
[3]   Study on temperature distribution and CO diffusion induced by cable fire in L-shaped utility tunnel [J].
An, Weiguang ;
Tang, Yanhua ;
Liang, Kai ;
Cai, Minglun ;
Wang, Tao ;
Wang, Zhe .
SUSTAINABLE CITIES AND SOCIETY, 2020, 62
[4]  
[Anonymous], 1995, GB 50045-95
[5]  
[Anonymous], 2015, GB50016-2014
[6]  
[Anonymous], 2015, GB50019-2015
[7]  
[Anonymous], 2013, GB 50116-98
[8]  
[Anonymous], 2020, CIGRE TB 815
[9]   A BN-based risk assessment model of natural gas pipelines integrating knowledge graph and DEMATEL [J].
Bai, Yiping ;
Wu, Jiansong ;
Ren, Qingru ;
Jiang, Yao ;
Cai, Jitao .
PROCESS SAFETY AND ENVIRONMENTAL PROTECTION, 2023, 171 :640-654
[10]   BN & CFD-based quantitative risk assessment of the natural gas explosion in utility tunnels [J].
Bai, Yiping ;
Wu, Jiansong ;
Sun, Yuxin ;
Cai, Jitao ;
Cao, Jiaojiao ;
Pang, Lei .
JOURNAL OF LOSS PREVENTION IN THE PROCESS INDUSTRIES, 2022, 80