Ultrasound assessment of endotracheal tube depth in neonates: a prospective feasibility study

被引:0
作者
Levkovitz, Orly [1 ,7 ]
Schujovitzky, Dana [2 ]
Stackievicz, Rodica [3 ]
Fayoux, Pierre [4 ]
Morag, Iris [5 ,6 ]
Litmanovitz, Ita [1 ,6 ]
Arnon, Shmuel [1 ,6 ]
Bauer, Sofia [1 ]
机构
[1] Meir Med Ctr, Dept Neonatol, Kefar Sava, Israel
[2] Meir Med Ctr, Pediat, Kefar Sava, Israel
[3] Meir Med Ctr, Dept Radiol, Kefar Sava, Israel
[4] Univ Lille, Dept Pediat Otolaryngol Head Neck Surg, Lille, France
[5] Shamir Med Ctr Assaf Harofeh, Dept Neonatol, Zerifin, Israel
[6] Tel Aviv Univ, Fac Med, Tel Aviv, Israel
[7] Meir Med Ctr, Dept Neonatol, IL-4428163 Kefar Sava, Israel
来源
ARCHIVES OF DISEASE IN CHILDHOOD-FETAL AND NEONATAL EDITION | 2024年 / 109卷 / 01期
关键词
Intensive Care Units; Neonatal; Neonatology; Respiratory Medicine; X-RAY; POSITION; ULTRASONOGRAPHY; CONFIRMATION; EXPOSURE; POINT; TIP;
D O I
10.1136/archdischild-2023-325855
中图分类号
R72 [儿科学];
学科分类号
100202 ;
摘要
ObjectiveTo examine the reliability of a novel ultrasound (US) method for assessment of endotracheal tube (ETT) position in neonates. DesignProspective, observational, single-centre, feasibility study. SettingLevel III neonatal intensive care unit. PatientsTerm and preterm neonates requiring endotracheal intubation. InterventionUS measurement of the ETT tip to right pulmonary artery (RPA) distance was used to determine ETT position according to one-fourth to three-fourths estimated tracheal length for weight. US demonstration of pleural sliding and diaphragmatic movement was also assessed. Chest radiography (CXR) was performed following each intubation. Main outcome measuresAgreement between US assessment of ETT tip position and CXR served as the gold standard. Sensitivity, specificity, positive and negative predictive values for each US method and correlation between ETT tip to RPA distance on US, and ETT tip to carina distance on CXR were assessed. ResultsForty-two US studies were performed on 33 intubated neonates. US evaluation of ETT-RPA distance identified 100% of ETTs positioned correctly: 77% deep and 80% high, demonstrating strong agreement with CXR (kappa=0.822). Sensitivity was 78%, specificity 100%, positive predictive value 100% and negative predictive value 86%. US ETT-RPA distance strongly correlated with CXR ETT-carina distance (r=0.826). No significant agreement was found between CXR and US assessment of pleural sliding and diaphragmatic movement. No adverse events were encountered during US scans. ConclusionUS evaluation of ETT-RPA distance demonstrated excellent accuracy for determining ETT position in neonates compared with CXR. More research is needed to support its feasibility in clinical settings.
引用
收藏
页码:94 / 99
页数:6
相关论文
共 35 条
[1]   Usefulness of bedside ultrasound compared to capnography and X-ray for tracheal intubation [J].
Alonso Quintela, P. ;
Oulego Erroz, I. ;
Mora Matilla, M. ;
Rodriguez Blanco, S. ;
Mata Zubillaga, D. ;
Regueras Santos, L. .
ANALES DE PEDIATRIA, 2014, 81 (05) :283-288
[2]   Exposure of extremely low birth weight infants to diagnostic X-Rays: a longitudinal study [J].
Arad, Ilan ;
Simanovsky, Natalia ;
Braunstein, Rony .
ACTA PAEDIATRICA, 2009, 98 (02) :266-269
[3]  
Arifin W.N., 2022, Sample size calculator
[4]   FIRST THORACIC VERTEBRAL BODY AS REFERENCE FOR ENDOTRACHEAL-TUBE PLACEMENT [J].
BLAYNEY, MP ;
LOGAN, DR .
ARCHIVES OF DISEASE IN CHILDHOOD-FETAL AND NEONATAL EDITION, 1994, 71 (01) :F32-F35
[5]   The concordance of ultrasound technique versus X-ray to confirm endotracheal tube position in neonates [J].
Chowdhry, R. ;
Dangman, B. ;
Pinheiro, J. M. B. .
JOURNAL OF PERINATOLOGY, 2015, 35 (07) :481-484
[6]   Ultrasound Confirmation of Endotracheal Tube Position in Neonates [J].
Dennington, Debra ;
Vali, Payam ;
Finer, Neil N. ;
Kim, Jae H. .
NEONATOLOGY, 2012, 102 (03) :185-189
[7]   Role of ultrasonography in the assessment of correct endotracheal tube placement in neonates [J].
Descamps, Claire-Sophie ;
Beissel, Anne ;
Van, Philippe Vo ;
Butin, Marine ;
Stacoffe, Nicolas ;
Giai, Joris ;
Claris, Olivier ;
Kim-An Nguyen .
ACTA PAEDIATRICA, 2020, 109 (05) :1057-1059
[8]  
Dominguez Mariana Chiaradia, 2018, Radiol Bras, V51, P20, DOI 10.1590/0100-3984.2016.0157
[9]   A GOODNESS-OF-FIT APPROACH TO INFERENCE PROCEDURES FOR THE KAPPA-STATISTIC - CONFIDENCE-INTERVAL CONSTRUCTION, SIGNIFICANCE-TESTING AND SAMPLE-SIZE ESTIMATION [J].
DONNER, A ;
ELIASZIW, M .
STATISTICS IN MEDICINE, 1992, 11 (11) :1511-1519
[10]   Position statement and best practice recommendations on the imaging use of ultrasound from the European Society of Radiology ultrasound subcommittee [J].
Clevert D.-A. ;
Nyhsen C. ;
Ricci P. ;
Sidhu P.S. ;
Tziakouri C. ;
Radziņa M. ;
Cantisani V. ;
Brady A.P. .
INSIGHTS INTO IMAGING, 2020, 11 (01)