Comparison of sacroiliac screw techniques for unstable sacroiliac joint disruptions: a finite element model analysis

被引:2
作者
Goncalves, Rafaela Mendes [1 ]
Freitas, Anderson [2 ]
Dourado Aragao, Vinicius Augusto [1 ]
Ramos Azevedo, Flavio Eduardo [1 ]
Lopes, Nerisvado Bonfim [1 ]
Alves Mangueira, Luna Jeannie [3 ]
Penteado da Silva, Luiz Henrique [4 ]
Pires, Robinson Esteves [5 ]
Giordano, Vincenzo [6 ]
机构
[1] Hosp Reg Gama, St Cent Area Especial 01, BR-72405901 Brasilia, DF, Brazil
[2] Hosp Ortoped & Med Especializada, SGAS Quadra 613-Conjunto C, BR-70200730 Brasilia, DF, Brazil
[3] Hosp Estadual Urgencias Governador Otavio Lage Si, Av Anhanguera,14 527 St Santos Dumont, BR-74463350 Goiania, Go, Brazil
[4] Inst Ortoped & Traumatol, Rua Uruguai,2050,4 Andar HSVP, BR-99010110 Passo Fundo, RS, Brazil
[5] Univ Fed Minas Gerais UFMG, Dept Locomot Apparat, Av Pres Antonio Carlos 6627, BR-31270901 Belo Horizonte, MG, Brazil
[6] Hosp Municipal Miguel Couto, Serv Ortoped & Traumatol Prof Nova Monteir, Rua Mario Ribeiro 1080, BR-22430160 Rio De Janeiro, RJ, Brazil
来源
INJURY-INTERNATIONAL JOURNAL OF THE CARE OF THE INJURED | 2023年 / 54卷
关键词
Pelvis; Vertical shear; Fixation; Biomechanical; Finite element models; POSTERIOR PELVIC RING; TRANSILIAC-TRANSSACRAL SCREWS; FIXATION TECHNIQUES; ILIOSACRAL SCREWS; INTERNAL-FIXATION; SACRUM FRACTURES; INJURIES; OSTEOSYNTHESIS; MANAGEMENT; PLACEMENT;
D O I
10.1016/j.injury.2023.05.014
中图分类号
R4 [临床医学];
学科分类号
1002 ; 100602 ;
摘要
Vertically unstable pelvic injuries associated with sacroiliac disruption are challenging. Although percutaneous iliosacral fixation using two screws at S1 vertebral body has been shown beneficial, the use of two transiliac screws at S1 has been proposed to increase the fixation strength of the construct. In the herein study, the finite element method (FEM) was performed to analyse the biomechanical behaviour of five different constructions using iliosacral screws only, transiliac screws only, and combining an iliosacral and a transiliac screw. A vertically unstable AO 61C1.2 type pelvic injury was produced for the evaluation of the posterior pelvic displacement and implant stress, and the anterior implant stress using FEM. The symphysis pubis was fixed with a 3.5-mm reconstruction plate in all cases. The model was axially loaded with 800N applied in the centre of S1 body, perpendicular to the ground (Y-axis), simulating the bipodal stance moment. There was a statistically significant reduction in both posterior displacement and implant stresses in the groups fixed with at least one transiliac screw compared to the groups fixed with iliosacral screws. In our FEM study, the construct using two transiliac screws in S1 is biomechanically superior for stabilizing the sacroiliac joint in vertically unstable pelvic ring injuries compared to the other configurations. Lateral displacement, posterior displacement, and von Mises stress were reduced with this construct. A good option can be the use of one iliosacral screw and one transiliac screw in S1.
引用
收藏
页数:8
相关论文
共 54 条
  • [1] [Anonymous], 1997, Oper Tech Orthop, DOI DOI 10.1016/S1048-6666(97)80060-2
  • [2] Percutaneous management of unstable pelvic ring disruptions
    Barei, DP
    Bellabarba, C
    Mills, WJ
    Routt, MLC
    [J]. INJURY-INTERNATIONAL JOURNAL OF THE CARE OF THE INJURED, 2001, 32 : 33 - 44
  • [3] Management of Hemodynamically Unstable Pelvic Ring Fractures
    Benders, Kim E. M.
    Leenen, Luke P. H.
    [J]. FRONTIERS IN SURGERY, 2020, 7
  • [4] Vertical shear pelvic injury: evaluation, management, and fixation strategies
    Blum, Laura
    Hake, Mark E.
    Charles, Ryan
    Conlan, Todd
    Rojas, David
    Martin, Murphy Trey
    Mauffrey, Cyril
    [J]. INTERNATIONAL ORTHOPAEDICS, 2018, 42 (11) : 2663 - 2674
  • [5] Safe placement of S1 and S2 iliosacral screws:: The "vestibule" concept
    Carlson, DA
    Scheid, DK
    Maar, DC
    Baele, JR
    Kaehr, DM
    [J]. JOURNAL OF ORTHOPAEDIC TRAUMA, 2000, 14 (04) : 264 - 269
  • [6] Pelvic trauma: WSES classification and guidelines
    Coccolini, Federico
    Stahel, Philip F.
    Montori, Giulia
    Biffl, Walter
    Horer, Tal M.
    Catena, Fausto
    Kluger, Yoram
    Moore, Ernest E.
    Peitzman, Andrew B.
    Ivatury, Rao
    Coimbra, Raul
    Fraga, Gustavo Pereira
    Pereira, Bruno
    Rizoli, Sandro
    Kirkpatrick, Andrew
    Leppaniemi, Ari
    Manfredi, Roberto
    Magnone, Stefano
    Chiara, Osvaldo
    Solaini, Leonardo
    Ceresoli, Marco
    Allievi, Niccolo
    Arvieux, Catherine
    Velmahos, George
    Balogh, Zsolt
    Naidoo, Noel
    Weber, Dieter
    Abu-Zidan, Fikri
    Sartelli, Massimo
    Ansaloni, Luca
    [J]. WORLD JOURNAL OF EMERGENCY SURGERY, 2017, 12
  • [7] Biomechanical comparison of posterior internal fixation techniques for unstable pelvic fractures
    Comstock, CP
    vanderMeulen, MCH
    Goodman, SB
    [J]. JOURNAL OF ORTHOPAEDIC TRAUMA, 1996, 10 (08) : 517 - 522
  • [8] Cruz Henrique Alves, 2013, Rev. bras. ortop., V48, P348, DOI [10.1016/j.rboe.2013.04.006, 10.1016/j.rbo.2013.04.002]
  • [9] Da Silva Jr WC, 2021, J Phys: Conf Ser, P1730
  • [10] Day C S, 2000, Am J Orthop (Belle Mead NJ), V29, P16