Pre- and Post-transcatheter Aortic Valve Replacement (TAVR) Serum Mean Platelet Volume Levels and All-Cause Mortality

被引:0
作者
Shina, Maya [1 ,5 ]
Kusniec, Fabio [1 ,5 ]
Rozen, Guy [2 ,6 ]
Carasso, Shemy [1 ,5 ]
Planer, David [3 ,4 ]
Alcalai, Ronny [3 ,4 ]
Grosman-Rimon, Liza [1 ,5 ]
Elbaz-Greener, Gabby [3 ,4 ,7 ]
Amir, Offer [3 ,4 ]
机构
[1] Tzafon Med Ctr, Dept Cardiol, Lower Galilee, Israel
[2] Hillel Yaffe Med Ctr, Dept Cardiol, Hadera, Israel
[3] Hadassah Med Org, Dept Cardiol, Jerusalem, Israel
[4] Hebrew Univ Jerusalem, Fac Med, Jerusalem, Israel
[5] Bar Ilan Univ, Azrieli Fac Med, Safed, Israel
[6] Technion Israel Inst Technol, Rappaport Fac Med, Haifa, Israel
[7] Hebrew Univ Jerusalem, Fac Med, Hadassah Med Ctr, Dept Cardiol, IL-91120 Jerusalem, Israel
来源
ISRAEL MEDICAL ASSOCIATION JOURNAL | 2023年 / 25卷 / 08期
关键词
aortic stenosis; mean platelet volume; mortality; platelet count; transcatheter aortic valve replacement (TAVR); IMPLANTATION; THROMBOCYTOPENIA;
D O I
暂无
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Background: Among the most frequent complications following transcatheter aortic valve replacement (TAVR) is hemostasis imbalance that presents either as thromboembolic or bleeding. Deviations in platelet count (PC) and mean platelet volume (MPV) are markers of hemostasis imbalance.Objectives: To determine the predictive value of pre-and post-procedural PC and MPV fL 1-year all-cause mortality in patients who underwent TAVR.Methods: In this population-based study, we included 236 TAVR patients treated at the Tzafon Medical Center between 1 June 2015 and 31 August 2018. Routine blood samples for serum PC levels and MPV fL were taken just before the TAVR and 24-hour post-TAVR. We used backward regression models to evaluate the predictive value of PC and MPV in all-cause mortality in TAVR patients.Results: In this study cohort, MPV levels 24-hour post-TAVR that were greater than the cohort median of 9 fL (interquartile range 8.5-9.8) were the strongest predictor of 1-year mortality (hazard ratio 1.343, 95% confidence interval 1.059-1.703, P-value 0.015). A statistically significant relationship was seen in the unadjusted regression model as well as after the adjustment for clinical variables.Conclusions: Serum MPV levels fL 24-hour post-procedure were found to be meaningful markers in predicting 1-year all cause mortality in patients after TAVR.
引用
收藏
页码:547 / 552
页数:6
相关论文
共 24 条
  • [1] Dimitrow Pawel Petkow, 2009, Atherosclerosis, V204, pe103, DOI 10.1016/j.atherosclerosis.2008.12.029
  • [2] Acquired thrombocytopenia after transcatheter aortic valve replacement: clinical correlates and association with outcomes
    Dvir, Danny
    Genereux, Philippe
    Barbash, Israel M.
    Kodali, Susheel
    Ben-Dor, Itsik
    Williams, Mathew
    Torguson, Rebecca
    Kirtane, Ajay J.
    Minha, Sa'ar
    Badr, Salem
    Pendyala, Lakshmana K.
    Loh, Joshua P.
    Okubagzi, Petros G.
    Fields, Jessica N.
    Xu, Ke
    Chen, Fang
    Hahn, Rebecca T.
    Satler, Lowell F.
    Smith, Craig
    Pichard, Augusto D.
    Leon, Martin B.
    Waksman, Ron
    [J]. EUROPEAN HEART JOURNAL, 2014, 35 (38) : 2663 - 2671
  • [3] Effect of Transcatheter (via Femoral Artery) Aortic Valve Implantation on the Platelet Count and Its Consequences
    Gallet, Romain
    Seemann, Aurelien
    Yamamoto, Masanori
    Hayat, Delphine
    Mouillet, Gauthier
    Monin, Jean-Luc
    Gueret, Pascal
    Couetil, Jean-Paul
    Dubois-Rande, Jean-Luc
    Teiger, Emmanuel
    Lim, Pascal
    [J]. AMERICAN JOURNAL OF CARDIOLOGY, 2013, 111 (11) : 1619 - 1624
  • [4] Paravalvular Leak After Transcatheter Aortic Valve Replacement The New Achilles' Heel? A Comprehensive Review of the Literature
    Genereux, Philippe
    Head, Stuart J.
    Hahn, Rebecca
    Daneault, Benoit
    Kodali, Susheel
    Williams, Mathew R.
    van Mieghem, Nicolas M.
    Alu, Maria C.
    Serruys, Patrick W.
    Kappetein, A. Pieter
    Leon, Martin B.
    [J]. JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 2013, 61 (11) : 1125 - 1136
  • [5] 2016 Annual Report of The Society of Thoracic Surgeons/American College of Cardiology Transcatheter Valve Therapy Registry
    Grover, Frederick L.
    Vemulapalli, Sreekanth
    Carroll, John D.
    Edwards, Fred H.
    Mack, Michael J.
    Thourani, Vinod H.
    Brindis, Ralph G.
    Shahian, David M.
    Ruiz, Carlos E.
    Jacobs, Jeffrey P.
    Hanzel, George
    Bavaria, Joseph E.
    Tuzcu, E. Murat
    Peterson, Eric D.
    Fitzgerald, Susan
    Kourtis, Matina
    Michaels, Joan
    Christensen, Barbara
    Seward, William F.
    Hewitt, Kathleen
    Holmes, David R., Jr.
    [J]. JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 2017, 69 (10) : 1215 - 1230
  • [6] Hematologic and Clinical Parameters After Transcatheter Aortic Valve Implantation (TAVI) in Patients With Severe Aortic Stenosis
    Gul, Mehmet
    Uyarel, Huseyin
    Akgul, Ozgur
    Uslu, Nevzat
    Yildirim, Aydin
    Eksik, Abdurrahman
    Aksu, Hale Unal
    Ozal, Ender
    Pusuroglu, Hamdi
    Erol, Mustafa Kemal
    Bakir, Ihsan
    [J]. CLINICAL AND APPLIED THROMBOSIS-HEMOSTASIS, 2014, 20 (03) : 304 - 310
  • [7] Major Thrombocytopenia after Balloon-Expandable Transcatheter Aortic Valve Replacement: Prognostic Implications and Comparison to Surgical Aortic Valve Replacement
    Jilaihawi, Hasan
    Doctor, Niraj
    Chakravarty, Tarun
    Kashif, Mohammad
    Mirocha, James
    Cheng, Wen
    Lill, Michael
    Nakamura, Mamoo
    Gheorghiu, Mitch
    Makkar, Raj R.
    [J]. CATHETERIZATION AND CARDIOVASCULAR INTERVENTIONS, 2015, 85 (01) : 130 - 137
  • [8] Dynamic changes in platelets caused by shear stress in aortic valve stenosis
    Kanda, Hideaki
    Yamakuchi, Munekazu
    Matsumoto, Kazuhisa
    Mukaihara, Kosuke
    Shigehisa, Yoshiya
    Tachioka, Shuji
    Okawa, Masashi
    Takenouchi, Kazunori
    Oyama, Yoko
    Hashiguchi, Teruto
    Imoto, Yutaka
    [J]. CLINICAL HEMORHEOLOGY AND MICROCIRCULATION, 2021, 77 (01) : 71 - 81
  • [9] Kappetein AP, 2012, J AM COLL CARDIOL, V60, P1438, DOI [10.1016/j.jacc.2012.09.001, 10.1093/ejcts/ezs533]
  • [10] Transcatheter Aortic-Valve Replacement with a Balloon-Expandable Valve in Low-Risk Patients
    Mack, M. J.
    Leon, M. B.
    Thourani, V. H.
    Makkar, R.
    Kodali, S. K.
    Russo, M.
    Kapadia, S. R.
    Malaisrie, S. C.
    Cohen, D. J.
    Pibarot, P.
    Leipsic, J.
    Hahn, R. T.
    Blanke, P.
    Williams, M. R.
    McCabe, J. M.
    Brown, D. L.
    Babaliaros, V.
    Goldman, S.
    Szeto, W. Y.
    Genereux, P.
    Pershad, A.
    Pocock, S. J.
    Alu, M. C.
    Webb, J. G.
    Smith, C. R.
    [J]. NEW ENGLAND JOURNAL OF MEDICINE, 2019, 380 (18) : 1695 - 1705