Effect of Electrocautery and Laser Treatment on the Composition and Morphology of Surface-Modified Titanium Implants

被引:3
|
作者
Lee, Jin-Seok [1 ]
Son, Keunbada [2 ]
Hwang, Sung-Min [1 ]
Son, Young-Tak [2 ,3 ]
Kim, Yong-Gun [1 ]
Suh, Jo-Young [1 ]
Hwang, Jun Ho [4 ]
Kwon, Sung-Min [4 ]
Lee, Jong Hoon [4 ]
Kim, Hyun Deok [5 ]
Lee, Kyu-Bok [6 ]
Lee, Jae-Mok [1 ]
机构
[1] Kyungpook Natl Univ, Sch Dent, Dept Periodontol, Daegu 41940, South Korea
[2] Kyungpook Natl Univ, Adv Dent Device Dev Inst A3DI, Daegu 41940, South Korea
[3] Kyungpook Natl Univ, Grad Sch, Dept Dent Sci, Daegu 41940, South Korea
[4] Kyungpook Natl Univ, Inst Adv Convergence Technol, Daegu 41061, South Korea
[5] Kyungpook Natl Univ, Sch Elect Engn, Daegu 41566, South Korea
[6] Kyungpook Natl Univ, Sch Dent, Dept Prosthodont, Daegu 41940, South Korea
来源
BIOENGINEERING-BASEL | 2023年 / 10卷 / 11期
基金
新加坡国家研究基金会;
关键词
dental implant; electrocautery treatment; laser treatment; surface roughness;
D O I
10.3390/bioengineering10111251
中图分类号
Q81 [生物工程学(生物技术)]; Q93 [微生物学];
学科分类号
071005 ; 0836 ; 090102 ; 100705 ;
摘要
The purpose of this study was to investigate the effects of different peri-implantitis treatment methods (Er,Cr:YSGG laser, diode laser, and electrocautery) on various titanium implant surfaces: machined; sandblasted, large-grit, and acid-etched; and femtosecond laser-treated surfaces. Grade 4 titanium (Ti) disks, with a diameter of 10 mm and a thickness of 1 mm, were fabricated and treated using the aforementioned techniques. Subsequently, each treated group of disks underwent different peri-implantitis treatment methods: Er,Cr:YSGG laser (Biolase, Inc., Foothill Ranch, CA, USA), diode laser (Biolase, Inc., Foothill Ranch, CA, USA), and electrocautery (Ellman, Hicksville, NY, USA). Scanning electron microscopy, energy-dispersive X-ray spectroscopy, and wettability were used to characterize the chemical compositions and surfaces of the treated titanium surfaces. Significant changes in surface roughness were observed in both the electrocautery (Sa value of machined surface = 0.469, SLA surface = 1.569, femtosecond laser surface = 1.741, and p = 0.025) and Er,Cr:YSGG laser (Ra value of machined surface = 1.034, SLA surface = 1.380, femtosecond laser surface = 1.437, and p = 0.025) groups. On femtosecond laser-treated titanium implant surfaces, all three treatment methods significantly reduced the surface contact angle (control = 82.2 degrees, diode laser = 74.3 degrees, Er,Cr:YSGG laser = 73.8 degrees, electrocautery = 76.2 degrees, and p = 0.039). Overall, Er,Cr:YSGG laser and electrocautery treatments significantly altered the surface roughness of titanium implant surfaces. As a result of surface composition after different peri-implantitis treatment methods, relative to the diode laser and electrocautery, the Er,Cr:YSGG laser increased oxygen concentration. The most dramatic change was observed after Er:Cr;YSGG laser treatment, urging caution for clinical applications. Changes in surface composition and wettability were observed but were not statistically significant. Further research is needed to understand the biological implications of these peri-implantitis treatment methods.
引用
收藏
页数:14
相关论文
共 50 条
  • [41] How does the surface treatment change the cytocompatibility of implants made by selective laser melting?
    Matouskova, Lucie
    Ackermann, Michal
    Horakova, Jana
    Capek, Lukas
    Henys, Petr
    Safka, Jiri
    EXPERT REVIEW OF MEDICAL DEVICES, 2018, 15 (04) : 313 - 321
  • [42] Composition and Structure of the Surface Layers of Tool Steel after Laser Treatment
    Sidashov A.V.
    Kozakov A.T.
    Yares’ko S.I.
    Manturov D.S.
    Russian Engineering Research, 2024, 44 (03) : 327 - 331
  • [43] Early Loading of Titanium Dental Implants with Hydroxyl Ion Modified Surface: A 12-Month Prospective Clinical Trial
    Krawiec, Maciej
    Hadzik, Jakub
    Dominiak, Marzena
    Grzebieluch, Wojciech
    Blaszczyszyn, Artur
    Kubasiewicz-Ross, Pawel
    APPLIED SCIENCES-BASEL, 2021, 11 (07):
  • [44] Investigations into morphology and surface integrity of micro-hole during femtosecond laser drilling of titanium alloy
    P. Deepu
    T. Jagadesh
    Muthukannan Duraiselvam
    Journal of the Brazilian Society of Mechanical Sciences and Engineering, 2023, 45
  • [45] Investigations into morphology and surface integrity of micro-hole during femtosecond laser drilling of titanium alloy
    Deepu, P.
    Jagadesh, T.
    Duraiselvam, Muthukannan
    JOURNAL OF THE BRAZILIAN SOCIETY OF MECHANICAL SCIENCES AND ENGINEERING, 2023, 45 (10)
  • [46] Effect of Plasma Treatment on Titanium Surface on the Tissue Surrounding Implant Material
    Tsujita, Hitomi
    Nishizaki, Hiroshi
    Miyake, Akiko
    Takao, Seiji
    Komasa, Satoshi
    INTERNATIONAL JOURNAL OF MOLECULAR SCIENCES, 2021, 22 (13)
  • [47] Zirconia Implants with Laser Surface Treatment: Peri-Implant Bone Response and Enhancement of Osseointegration
    Yasuno, Kimie
    Kakura, Kae
    Taniguchi, Yusuke
    Yamaguchi, Yuichiro
    Kido, Hirofumi
    JOURNAL OF HARD TISSUE BIOLOGY, 2014, 23 (01) : 93 - 100
  • [48] Laser surface treatment on Yttria-stabilized zirconia dental implants: Influence on cell behavior
    da Cruz, Mariana Brito
    Marques, Joana Faria
    Fernandes, Beatriz Ferreira
    Pinto, Paulo
    Madeira, Sara
    Carvalho, Oscar
    Silva, Filipe Samuel
    Carames, Joao Manuel Mendez
    da Mata, Antonio Duarte Sola Pereira
    JOURNAL OF BIOMEDICAL MATERIALS RESEARCH PART B-APPLIED BIOMATERIALS, 2022, 110 (01) : 249 - 258
  • [49] The effect of plasma surface treatment on the bioactivity of titanium implant materials (in vitro)
    Abdelrahim, Ramy A.
    Badr, Nadia A.
    Baroudi, Kusai
    JOURNAL OF INTERNATIONAL SOCIETY OF PREVENTIVE AND COMMUNITY DENTISTRY, 2016, 6 (01) : 15 - 21
  • [50] Influence of Surface Laser Treatment on Mechanical Properties and Residual Stresses of Titanium and its Alloys
    Jazdzewska, Magdalena
    Majkowska-Marzec, Beata
    Ostrowski, Roman
    Olive, Jean-Marc
    ADVANCES IN SCIENCE AND TECHNOLOGY-RESEARCH JOURNAL, 2023, 17 (06) : 27 - 38